123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246 |
- {
- "norm": "js_tn",
- "system": "你是一位经验丰富的污水处理厂专家。总氮是衡量水中氮污染程度的一个重要指标。进水总氮超标意味着处理前的水仍然含有较高浓度的氮污染物,不符合处理要求。\n以下是污水处理厂的一些关键指标数据:\n\n<begin>\n进水总氮:当前值为{{TN_in}}mg/L,设计值为{{TN_in_name}}mg/L。\n进水COD:当前值为{{COD_in}}mg/L,设计值为{{COD_in_name}}mg/L。\n进水总磷:当前值为{{TP_in}}mg/L,设计值为{{TP_in_name}}mg/L。\n进水氨氮:当前值为{{andan_in}}mg/L,设计值为{{andan_in_name}}mg/L。\n进水TDS:当前值为{{TDS_in}}mg/L,TDS管控值为{{TDS_in_name}}mg/L。\n出水总氮:当前值为{{TN_off}}mg/L,标准值为{{TN_off_name}}mg/L,管控值为{{TN_off_con}}mg/L。\n<line>\n进水总氮{{continuity}}连续检测数据超标。\n进水总氮{{exceed}}。\n出水总氮{{check_rise}}。\n进水总氮超标持续时间{{time_tips}}6小时。\n<end>\n\n请根据以上数据回答下列问题,只需给出问题后括号内的选项即可,无需解释:\n\n进水总氮超标持续时间是否超过6小时?(“超过”,“未超过”)\n出水总氮存在升高趋势和超标吗?(\"存在升高趋势且超标\",\"存在升高趋势但未超标\",\"不存在升高趋势且未超标\",\"不存在升高趋势但超标\")",
- "prompt": "<begin>\n内回流⽐:当前值是{{r}},建议调整值是{{r_wentai}}。\n{% for item in mlss_items -%}\n池{{loop.index}}生化池污泥浓度 MLSS:当前值{{item.MLSS}},建议调整值{{item.MLSS_wentai}}。\n{%- endfor %}\n进水水量:当前值是{{Q_in}},建议调整值是{{Q_in_wentai}}。\n<end>",
- "data_desc": "",
- "boot": [
- "2_2"
- ],
- "questions": [
- {
- "id": "2_2",
- "mainType": "text",
- "mainContent": "进水总氮超标持续时间是否超过6小时?",
- "options": [
- {
- "option": "超过",
- "next": [
- "4_2",
- "4_3"
- ]
- },
- {
- "option": "未超过",
- "next": [
- "4_7",
- "4_11"
- ]
- }
- ]
- },
- {
- "id": "3_2",
- "mainType": "text",
- "mainContent": "超过",
- "options": [
- {
- "option": "解决方案:\n- 当前水质状态:进水总氮{{continuity}}连续检测数据超标,进水总氮对比设计值{{exceed}},进水总氮超标持续时间超过6小时。\n- 按水样保存方法及时对超标水样保存,应保存三组平行水样。异常进水指标检测频次为 3 次/日,并视响应级别组织第三方现场增加采样频次。\n- 同步拍摄取样、化验照片或录像保存异常证据\n- 向行业主管部门报备,同步启动进水水质溯源工作,取样送检并留存影像等相关佐证免责材料,并配合主管部门的调查认定工作。",
- "next": [
- "5_2"
- ]
- },
- {
- "option": "出水总氮存在升高趋势和超标吗?",
- "next": [
- "5_3",
- "5_4",
- "5_5",
- "5_6"
- ]
- }
- ]
- },
- {
- "id": "3_7",
- "mainType": "text",
- "mainContent": "未超过",
- "options": [
- {
- "option": "出水总氮存在升高趋势和超标吗?",
- "next": [
- "5_7",
- "5_8",
- "5_9",
- "5_10"
- ]
- },
- {
- "option": "解决方案:\n- 当前水质状态:进水总氮{{continuity}}连续检测数据超标,进水总氮对比设计值{{exceed}},进水总磷超标持续时间未超过6小时。\n- 第一时间启动水质溯源排查,需要进行超标进水处置与影像保存相关工作\n- 按水样保存方法及时对超标水样保存,应保存三组平行水样。异常进水指标检测频次为 3 次/日,并视响应级别组织第三方现场增加采样频次。\n- 同步拍摄取样、化验照片或录像保存异常证据",
- "next": [
- "5_11"
- ]
- }
- ]
- },
- {
- "id": "4_2",
- "mainType": "export",
- "mainContent": "解决方案:\n- 当前水质状态:进水总氮{{continuity}}连续检测数据超标,进水总氮对比设计值{{exceed}},进水总氮超标持续时间超过6小时。\n- 按水样保存方法及时对超标水样保存,应保存三组平行水样。异常进水指标检测频次为 3 次/日,并视响应级别组织第三方现场增加采样频次。\n- 同步拍摄取样、化验照片或录像保存异常证据\n- 向行业主管部门报备,同步启动进水水质溯源工作,取样送检并留存影像等相关佐证免责材料,并配合主管部门的调查认定工作。",
- "options": []
- },
- {
- "id": "4_3",
- "mainType": "text",
- "mainContent": "出水总氮存在升高趋势和超标吗?",
- "options": [
- {
- "option": "存在升高趋势且超标",
- "next": [
- "6_3"
- ]
- },
- {
- "option": "不存在升高趋势但超标",
- "next": [
- "6_4"
- ]
- },
- {
- "option": "不存在升高趋势且未超标",
- "next": [
- "6_5"
- ]
- },
- {
- "option": "存在升高趋势但未超标",
- "next": [
- "6_6"
- ]
- }
- ]
- },
- {
- "id": "4_7",
- "mainType": "text",
- "mainContent": "出水总氮存在升高趋势和超标吗?",
- "options": [
- {
- "option": "存在升高趋势且超标",
- "next": [
- "6_7"
- ]
- },
- {
- "option": "不存在升高趋势但超标",
- "next": [
- "6_8"
- ]
- },
- {
- "option": "不存在升高趋势且未超标",
- "next": [
- "6_9"
- ]
- },
- {
- "option": "存在升高趋势但未超标",
- "next": [
- "6_10"
- ]
- }
- ]
- },
- {
- "id": "4_11",
- "mainType": "export",
- "mainContent": "解决方案:\n- 当前水质状态:进水总氮{{continuity}}连续检测数据超标,进水总氮对比设计值{{exceed}},进水总磷超标持续时间未超过6小时。\n- 第一时间启动水质溯源排查,需要进行超标进水处置与影像保存相关工作\n- 按水样保存方法及时对超标水样保存,应保存三组平行水样。异常进水指标检测频次为 3 次/日,并视响应级别组织第三方现场增加采样频次。\n- 同步拍摄取样、化验照片或录像保存异常证据",
- "options": []
- },
- {
- "id": "5_3",
- "mainType": "text",
- "mainContent": "存在升高趋势且超标",
- "options": []
- },
- {
- "id": "5_4",
- "mainType": "text",
- "mainContent": "不存在升高趋势但超标",
- "options": []
- },
- {
- "id": "5_5",
- "mainType": "text",
- "mainContent": "不存在升高趋势且未超标",
- "options": []
- },
- {
- "id": "5_6",
- "mainType": "text",
- "mainContent": "存在升高趋势但未超标",
- "options": []
- },
- {
- "id": "5_7",
- "mainType": "text",
- "mainContent": "存在升高趋势且超标",
- "options": []
- },
- {
- "id": "5_8",
- "mainType": "text",
- "mainContent": "不存在升高趋势但超标",
- "options": []
- },
- {
- "id": "5_9",
- "mainType": "text",
- "mainContent": "不存在升高趋势且未超标",
- "options": []
- },
- {
- "id": "5_10",
- "mainType": "text",
- "mainContent": "存在升高趋势但未超标",
- "options": []
- },
- {
- "id": "6_3",
- "mainType": "export",
- "mainContent": "解决方案:\n- 当前水质状态:出生总氮存在升高趋势且超标。\n- 启动应急预案,与行业主管部门建立联动机制,合规履行项目协议相关条款。",
- "options": []
- },
- {
- "id": "6_4",
- "mainType": "export",
- "mainContent": "解决方案:\n- 当前水质状态:出水总氮超标。\n- 启动应急预案,与行业主管部门建立联动机制,合规履行项目协议相关条款。",
- "options": []
- },
- {
- "id": "6_5",
- "mainType": "export",
- "mainContent": "",
- "options": []
- },
- {
- "id": "6_6",
- "mainType": "export",
- "mainContent": "解决方案:\n- 当前水质状态:进水总氮{{continuity}}连续检测数据超标,进水总氮对比设计值{{exceed}},进水总氮超标持续时间超过6小时,出水总氮存在升高趋势但未超标。\n- 需要对水量分配,曝气风量, 回流,污泥浓度等具体工艺参数进行调整,以保障出水稳定。具体工艺参数的调整原则参照如下:\n- 水量分配:内外部具备水量调整条件的,进水量的调整幅度每次5%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,检测校核调整效果。\n- 回流量:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,检测校核调整效果。\n- 污泥浓度:提高污泥浓度,调整幅度控制不超过常态稳定时的10%,A²O等连续流工艺均以日为单位,检测校核调整效果。",
- "options": []
- },
- {
- "id": "6_7",
- "mainType": "export",
- "mainContent": "解决方案:\n- 当前水质状态:出生总氮存在升高趋势且超标。\n- 启动应急预案,与行业主管部门建立联动机制,合规履行项目协议相关条款。",
- "options": []
- },
- {
- "id": "6_8",
- "mainType": "export",
- "mainContent": "解决方案:\n- 当前水质状态:出水总氮超标。\n- 启动应急预案,与行业主管部门建立联动机制,合规履行项目协议相关条款。",
- "options": []
- },
- {
- "id": "6_9",
- "mainType": "export",
- "mainContent": "",
- "options": []
- },
- {
- "id": "6_10",
- "mainType": "export",
- "mainContent": "解决方案:\n- 当前水质状态:进水总氮{{continuity}}连续检测数据超标,进水总氮对比设计值{{exceed}},进水总氮超标持续时间未超过6小时,出水总氮存在升高趋势但未超标。\n- 需要对水量分配,曝气风量, 回流,污泥浓度等具体工艺参数进行调整,以保障出水稳定。具体工艺参数的调整原则参照如下:\n- 水量分配:内外部具备水量调整条件的,进水量的调整幅度每次5%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,检测校核调整效果。\n- 回流量:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,检测校核调整效果。\n- 污泥浓度:提高污泥浓度,调整幅度控制不超过常态稳定时的10%,A²O等连续流工艺均以日为单位,检测校核调整效果。",
- "options": []
- }
- ]
- }
|