12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182838485868788899091929394959697989910010110210310410510610710810911011111211311411511611711811912012112212312412512612712812913013113213313413513613713813914014114214314414514614714814915015115215315415515615715815916016116216316416516616716816917017117217317417517617717817918018118218318418518618718818919019119219319419519619719819920020120220320420520620720820921021121221321421521621721821922022122222322422522622722822923023123223323423523623723823924024124224324424524624724824925025125225325425525625725825926026126226326426526626726826927027127227327427527627727827928028128228328428528628728828929029129229329429529629729829930030130230330430530630730830931031131231331431531631731831932032132232332432532632732832933033133233333433533633733833934034134234334434534634734834935035135235335435535635735835936036136236336436536636736836937037137237337437537637737837938038138238338438538638738838939039139239339439539639739839940040140240340440540640740840941041141241341441541641741841942042142242342442542642742842943043143243343443543643743843944044144244344444544644744844945045145245345445545645745845946046146246346446546646746846947047147247347447547647747847948048148248348448548648748848949049149249349449549649749849950050150250350450550650750850951051151251351451551651751851952052152252352452552652752852953053153253353453553653753853954054154254354454554654754854955055155255355455555655755855956056156256356456556656756856957057157257357457557657757857958058158258358458558658758858959059159259359459559659759859960060160260360460560660760860961061161261361461561661761861962062162262362462562662762862963063163263363463563663763863964064164264364464564664764864965065165265365465565665765865966066166266366466566666766866967067167267367467567667767867968068168268368468568668768868969069169269369469569669769869970070170270370470570670770870971071171271371471571671771871972072172272372472572672772872973073173273373473573673773873974074174274374474574674774874975075175275375475575675775875976076176276376476576676776876977077177277377477577677777877978078178278378478578678778878979079179279379479579679779879980080180280380480580680780880981081181281381481581681781881982082182282382482582682782882983083183283383483583683783883984084184284384484584684784884985085185285385485585685785885986086186286386486586686786886987087187287387487587687787887988088188288388488588688788888989089189289389489589689789889990090190290390490590690790890991091191291391491591691791891992092192292392492592692792892993093193293393493593693793893994094194294394494594694794894995095195295395495595695795895996096196296396496596696796896997097197297397497597697797897998098198298398498598698798898999099199299399499599699799899910001001100210031004100510061007100810091010101110121013101410151016101710181019102010211022102310241025102610271028102910301031103210331034103510361037103810391040104110421043104410451046104710481049105010511052105310541055105610571058105910601061106210631064106510661067106810691070107110721073107410751076107710781079108010811082108310841085108610871088108910901091109210931094109510961097109810991100110111021103110411051106110711081109111011111112111311141115111611171118111911201121112211231124112511261127112811291130113111321133113411351136113711381139114011411142114311441145114611471148114911501151115211531154115511561157115811591160116111621163116411651166116711681169117011711172117311741175117611771178117911801181118211831184118511861187118811891190119111921193119411951196119711981199120012011202120312041205120612071208120912101211121212131214121512161217121812191220122112221223122412251226122712281229123012311232123312341235123612371238123912401241124212431244124512461247124812491250125112521253125412551256125712581259126012611262126312641265126612671268126912701271127212731274127512761277127812791280128112821283128412851286128712881289129012911292129312941295129612971298129913001301130213031304130513061307130813091310131113121313131413151316131713181319132013211322132313241325132613271328132913301331133213331334133513361337133813391340134113421343134413451346134713481349135013511352135313541355135613571358135913601361136213631364136513661367136813691370137113721373137413751376137713781379138013811382138313841385138613871388138913901391139213931394139513961397139813991400140114021403140414051406140714081409141014111412141314141415141614171418141914201421142214231424142514261427142814291430143114321433143414351436143714381439144014411442144314441445144614471448144914501451145214531454145514561457145814591460146114621463146414651466146714681469147014711472147314741475147614771478147914801481148214831484148514861487148814891490149114921493149414951496149714981499150015011502150315041505150615071508150915101511151215131514151515161517151815191520152115221523152415251526152715281529153015311532153315341535153615371538153915401541154215431544154515461547154815491550155115521553155415551556155715581559156015611562156315641565156615671568156915701571157215731574157515761577157815791580158115821583158415851586158715881589159015911592159315941595159615971598159916001601160216031604160516061607160816091610161116121613161416151616161716181619162016211622162316241625162616271628162916301631163216331634163516361637163816391640164116421643164416451646164716481649165016511652165316541655165616571658165916601661166216631664166516661667166816691670167116721673167416751676167716781679168016811682168316841685168616871688168916901691169216931694169516961697169816991700170117021703170417051706170717081709171017111712171317141715171617171718171917201721172217231724172517261727172817291730173117321733173417351736173717381739174017411742174317441745174617471748174917501751175217531754175517561757175817591760176117621763176417651766176717681769177017711772177317741775177617771778177917801781178217831784178517861787178817891790179117921793179417951796179717981799180018011802180318041805180618071808180918101811181218131814181518161817181818191820182118221823182418251826182718281829183018311832183318341835183618371838183918401841184218431844184518461847184818491850185118521853185418551856185718581859186018611862186318641865186618671868186918701871187218731874187518761877187818791880188118821883188418851886188718881889189018911892189318941895189618971898189919001901190219031904190519061907190819091910191119121913191419151916191719181919192019211922192319241925192619271928192919301931193219331934193519361937193819391940194119421943194419451946194719481949195019511952195319541955195619571958195919601961196219631964196519661967196819691970197119721973197419751976197719781979198019811982198319841985198619871988198919901991199219931994199519961997199819992000200120022003200420052006200720082009201020112012201320142015201620172018201920202021202220232024202520262027202820292030203120322033203420352036203720382039204020412042204320442045204620472048204920502051205220532054205520562057205820592060206120622063206420652066206720682069207020712072207320742075207620772078207920802081208220832084208520862087208820892090209120922093209420952096209720982099210021012102210321042105210621072108210921102111211221132114211521162117211821192120212121222123212421252126212721282129213021312132213321342135213621372138213921402141214221432144214521462147214821492150215121522153215421552156215721582159216021612162216321642165216621672168216921702171217221732174217521762177217821792180218121822183218421852186218721882189219021912192219321942195219621972198219922002201220222032204220522062207220822092210221122122213221422152216221722182219222022212222222322242225222622272228222922302231223222332234223522362237223822392240224122422243224422452246224722482249225022512252225322542255225622572258225922602261226222632264226522662267226822692270227122722273227422752276227722782279228022812282228322842285228622872288228922902291229222932294229522962297229822992300230123022303230423052306230723082309231023112312231323142315231623172318231923202321232223232324232523262327232823292330233123322333233423352336233723382339234023412342234323442345234623472348234923502351235223532354235523562357235823592360236123622363236423652366236723682369237023712372237323742375237623772378237923802381238223832384238523862387238823892390239123922393239423952396239723982399240024012402240324042405240624072408240924102411241224132414241524162417241824192420242124222423242424252426242724282429243024312432243324342435243624372438243924402441244224432444244524462447244824492450245124522453245424552456245724582459246024612462246324642465246624672468246924702471247224732474247524762477247824792480248124822483248424852486248724882489249024912492249324942495249624972498249925002501250225032504250525062507250825092510251125122513251425152516251725182519252025212522252325242525252625272528252925302531253225332534253525362537253825392540254125422543254425452546254725482549255025512552255325542555255625572558255925602561256225632564256525662567256825692570257125722573257425752576257725782579258025812582258325842585258625872588258925902591259225932594259525962597259825992600260126022603260426052606260726082609261026112612261326142615261626172618261926202621262226232624262526262627262826292630263126322633263426352636263726382639264026412642264326442645264626472648264926502651265226532654265526562657265826592660266126622663266426652666266726682669267026712672267326742675267626772678267926802681268226832684268526862687268826892690269126922693269426952696269726982699270027012702270327042705270627072708270927102711271227132714271527162717271827192720272127222723272427252726272727282729273027312732273327342735273627372738273927402741274227432744274527462747274827492750275127522753275427552756275727582759276027612762276327642765276627672768276927702771277227732774277527762777277827792780278127822783278427852786278727882789279027912792279327942795279627972798279928002801280228032804280528062807280828092810281128122813281428152816281728182819282028212822282328242825282628272828282928302831283228332834283528362837283828392840284128422843284428452846284728482849285028512852285328542855285628572858285928602861286228632864286528662867286828692870287128722873287428752876287728782879288028812882288328842885288628872888288928902891289228932894289528962897289828992900290129022903290429052906290729082909291029112912291329142915291629172918291929202921292229232924292529262927292829292930293129322933293429352936293729382939294029412942294329442945294629472948294929502951295229532954295529562957295829592960296129622963296429652966296729682969297029712972297329742975297629772978297929802981298229832984298529862987298829892990299129922993299429952996299729982999300030013002300330043005300630073008300930103011301230133014301530163017301830193020302130223023302430253026302730283029303030313032303330343035303630373038303930403041304230433044304530463047304830493050305130523053305430553056305730583059306030613062306330643065306630673068306930703071307230733074307530763077307830793080308130823083308430853086308730883089309030913092309330943095309630973098309931003101310231033104310531063107310831093110311131123113311431153116311731183119312031213122312331243125312631273128312931303131313231333134313531363137313831393140314131423143314431453146314731483149315031513152315331543155315631573158315931603161316231633164316531663167316831693170317131723173317431753176317731783179318031813182318331843185318631873188318931903191319231933194319531963197319831993200320132023203320432053206320732083209321032113212321332143215321632173218321932203221322232233224322532263227322832293230323132323233323432353236323732383239324032413242324332443245324632473248324932503251325232533254325532563257325832593260326132623263326432653266326732683269327032713272327332743275327632773278327932803281328232833284328532863287328832893290329132923293329432953296329732983299330033013302330333043305330633073308330933103311331233133314331533163317331833193320332133223323332433253326332733283329333033313332333333343335333633373338333933403341334233433344334533463347334833493350335133523353335433553356335733583359336033613362336333643365336633673368336933703371337233733374337533763377337833793380338133823383338433853386338733883389339033913392339333943395339633973398339934003401340234033404340534063407340834093410341134123413341434153416341734183419342034213422342334243425342634273428342934303431343234333434343534363437343834393440344134423443344434453446344734483449345034513452345334543455345634573458345934603461346234633464346534663467346834693470347134723473347434753476347734783479348034813482348334843485348634873488348934903491349234933494349534963497349834993500350135023503350435053506350735083509351035113512351335143515351635173518351935203521352235233524352535263527352835293530353135323533353435353536353735383539354035413542354335443545354635473548354935503551355235533554355535563557355835593560356135623563356435653566356735683569357035713572357335743575357635773578357935803581358235833584358535863587358835893590359135923593359435953596359735983599360036013602360336043605360636073608360936103611361236133614361536163617361836193620362136223623362436253626362736283629363036313632363336343635363636373638363936403641364236433644364536463647364836493650365136523653365436553656365736583659366036613662366336643665366636673668366936703671367236733674367536763677367836793680368136823683368436853686368736883689369036913692369336943695369636973698369937003701370237033704370537063707370837093710371137123713371437153716371737183719372037213722372337243725372637273728372937303731373237333734373537363737373837393740374137423743374437453746374737483749375037513752375337543755375637573758375937603761376237633764376537663767376837693770377137723773377437753776377737783779378037813782378337843785378637873788378937903791379237933794379537963797379837993800380138023803380438053806380738083809381038113812381338143815381638173818381938203821382238233824382538263827382838293830383138323833383438353836383738383839384038413842384338443845384638473848384938503851385238533854385538563857385838593860386138623863386438653866386738683869387038713872387338743875387638773878387938803881388238833884388538863887388838893890389138923893389438953896389738983899390039013902390339043905390639073908390939103911391239133914391539163917391839193920392139223923392439253926392739283929393039313932393339343935393639373938393939403941394239433944394539463947394839493950395139523953395439553956395739583959396039613962396339643965396639673968396939703971397239733974397539763977397839793980398139823983398439853986398739883989399039913992399339943995399639973998399940004001400240034004400540064007400840094010401140124013401440154016401740184019402040214022402340244025402640274028402940304031403240334034403540364037403840394040404140424043404440454046404740484049405040514052405340544055405640574058405940604061406240634064406540664067406840694070407140724073407440754076407740784079408040814082408340844085408640874088408940904091409240934094409540964097409840994100410141024103410441054106410741084109411041114112411341144115411641174118411941204121412241234124412541264127412841294130413141324133413441354136413741384139414041414142414341444145414641474148414941504151415241534154415541564157415841594160416141624163416441654166416741684169417041714172417341744175417641774178417941804181418241834184418541864187418841894190419141924193419441954196419741984199420042014202420342044205420642074208420942104211421242134214421542164217421842194220422142224223422442254226422742284229423042314232423342344235423642374238423942404241424242434244424542464247424842494250425142524253425442554256425742584259426042614262426342644265426642674268426942704271427242734274427542764277427842794280428142824283428442854286428742884289429042914292429342944295429642974298429943004301430243034304430543064307430843094310431143124313431443154316431743184319432043214322432343244325432643274328432943304331433243334334433543364337433843394340434143424343434443454346434743484349435043514352435343544355435643574358435943604361436243634364436543664367436843694370437143724373437443754376437743784379438043814382438343844385438643874388438943904391439243934394439543964397439843994400440144024403440444054406440744084409441044114412441344144415441644174418441944204421442244234424442544264427442844294430443144324433443444354436443744384439444044414442444344444445444644474448444944504451445244534454445544564457445844594460446144624463446444654466446744684469447044714472447344744475447644774478447944804481448244834484448544864487448844894490449144924493449444954496449744984499450045014502450345044505450645074508450945104511451245134514451545164517451845194520452145224523452445254526452745284529453045314532453345344535453645374538453945404541454245434544454545464547454845494550455145524553455445554556455745584559456045614562456345644565456645674568456945704571457245734574457545764577457845794580458145824583458445854586458745884589459045914592459345944595459645974598459946004601460246034604460546064607460846094610461146124613461446154616461746184619462046214622462346244625462646274628462946304631463246334634463546364637463846394640464146424643464446454646464746484649465046514652465346544655465646574658465946604661466246634664466546664667466846694670467146724673467446754676467746784679468046814682468346844685468646874688468946904691469246934694469546964697469846994700470147024703470447054706470747084709471047114712471347144715471647174718471947204721472247234724472547264727472847294730473147324733473447354736473747384739474047414742474347444745474647474748474947504751475247534754475547564757475847594760476147624763476447654766476747684769477047714772477347744775477647774778477947804781478247834784478547864787478847894790479147924793479447954796479747984799480048014802480348044805480648074808480948104811481248134814481548164817481848194820482148224823482448254826482748284829483048314832483348344835483648374838483948404841484248434844484548464847484848494850485148524853485448554856485748584859486048614862486348644865486648674868486948704871487248734874487548764877487848794880488148824883488448854886488748884889489048914892489348944895489648974898489949004901490249034904490549064907490849094910491149124913491449154916491749184919492049214922492349244925492649274928492949304931493249334934493549364937493849394940494149424943494449454946494749484949495049514952495349544955495649574958495949604961496249634964496549664967496849694970497149724973497449754976497749784979498049814982498349844985498649874988498949904991499249934994499549964997499849995000500150025003500450055006500750085009501050115012501350145015501650175018501950205021502250235024502550265027502850295030503150325033503450355036503750385039504050415042504350445045504650475048504950505051505250535054505550565057505850595060506150625063506450655066506750685069507050715072507350745075507650775078507950805081508250835084508550865087508850895090509150925093509450955096509750985099510051015102510351045105510651075108510951105111511251135114511551165117511851195120512151225123512451255126512751285129513051315132513351345135513651375138513951405141514251435144514551465147514851495150515151525153515451555156515751585159516051615162516351645165516651675168516951705171517251735174517551765177517851795180518151825183518451855186518751885189519051915192519351945195519651975198519952005201520252035204520552065207520852095210521152125213521452155216521752185219522052215222522352245225522652275228522952305231523252335234523552365237523852395240524152425243524452455246524752485249525052515252525352545255525652575258525952605261526252635264526552665267526852695270527152725273527452755276527752785279528052815282528352845285528652875288528952905291529252935294529552965297529852995300530153025303530453055306530753085309531053115312531353145315531653175318531953205321532253235324532553265327532853295330533153325333533453355336533753385339534053415342534353445345534653475348534953505351535253535354535553565357535853595360536153625363536453655366536753685369537053715372537353745375537653775378537953805381538253835384538553865387538853895390539153925393539453955396539753985399540054015402540354045405540654075408540954105411541254135414541554165417541854195420542154225423542454255426542754285429543054315432543354345435543654375438543954405441544254435444544554465447544854495450545154525453545454555456545754585459546054615462546354645465546654675468546954705471547254735474547554765477547854795480548154825483548454855486548754885489549054915492549354945495549654975498549955005501550255035504550555065507550855095510551155125513551455155516551755185519552055215522552355245525552655275528552955305531553255335534553555365537553855395540554155425543554455455546554755485549555055515552555355545555555655575558555955605561556255635564556555665567556855695570557155725573557455755576557755785579558055815582558355845585558655875588558955905591559255935594559555965597559855995600560156025603560456055606560756085609561056115612561356145615561656175618561956205621562256235624562556265627562856295630563156325633563456355636563756385639564056415642564356445645564656475648564956505651565256535654565556565657565856595660566156625663566456655666566756685669567056715672567356745675567656775678567956805681568256835684568556865687568856895690569156925693569456955696569756985699570057015702570357045705570657075708570957105711571257135714571557165717571857195720572157225723572457255726572757285729573057315732573357345735573657375738573957405741574257435744574557465747574857495750575157525753575457555756575757585759576057615762576357645765576657675768576957705771577257735774577557765777577857795780578157825783578457855786578757885789579057915792579357945795579657975798579958005801580258035804580558065807580858095810581158125813581458155816581758185819582058215822582358245825582658275828582958305831583258335834583558365837583858395840584158425843584458455846584758485849585058515852585358545855585658575858585958605861586258635864586558665867586858695870587158725873587458755876587758785879588058815882588358845885588658875888588958905891589258935894589558965897589858995900590159025903590459055906590759085909591059115912591359145915591659175918591959205921592259235924592559265927592859295930593159325933593459355936593759385939594059415942594359445945594659475948594959505951595259535954595559565957595859595960596159625963596459655966596759685969597059715972597359745975597659775978597959805981598259835984598559865987598859895990599159925993599459955996599759985999600060016002600360046005600660076008600960106011601260136014601560166017601860196020602160226023602460256026602760286029603060316032603360346035603660376038603960406041604260436044604560466047604860496050605160526053605460556056605760586059606060616062606360646065606660676068606960706071607260736074607560766077607860796080608160826083608460856086608760886089609060916092609360946095609660976098609961006101610261036104610561066107610861096110611161126113611461156116611761186119612061216122612361246125612661276128612961306131613261336134613561366137613861396140614161426143614461456146614761486149615061516152615361546155615661576158615961606161616261636164616561666167616861696170617161726173617461756176617761786179618061816182618361846185618661876188618961906191619261936194619561966197619861996200620162026203620462056206620762086209621062116212621362146215621662176218621962206221622262236224622562266227622862296230623162326233623462356236623762386239624062416242624362446245624662476248624962506251625262536254625562566257625862596260626162626263626462656266626762686269627062716272627362746275627662776278627962806281628262836284628562866287628862896290629162926293629462956296629762986299630063016302630363046305630663076308630963106311631263136314631563166317631863196320632163226323632463256326632763286329633063316332633363346335633663376338633963406341634263436344634563466347634863496350635163526353635463556356635763586359636063616362636363646365636663676368636963706371637263736374637563766377637863796380638163826383638463856386638763886389639063916392639363946395639663976398639964006401640264036404640564066407640864096410641164126413641464156416641764186419642064216422642364246425642664276428642964306431643264336434643564366437643864396440644164426443644464456446644764486449645064516452645364546455645664576458645964606461646264636464646564666467646864696470647164726473647464756476647764786479648064816482648364846485648664876488648964906491649264936494649564966497649864996500650165026503650465056506650765086509651065116512651365146515651665176518651965206521652265236524652565266527652865296530653165326533653465356536653765386539654065416542654365446545654665476548654965506551655265536554655565566557655865596560656165626563656465656566656765686569657065716572657365746575657665776578657965806581658265836584658565866587658865896590659165926593659465956596659765986599660066016602660366046605660666076608660966106611661266136614661566166617661866196620662166226623662466256626662766286629663066316632663366346635663666376638663966406641664266436644664566466647664866496650665166526653665466556656665766586659666066616662666366646665666666676668666966706671667266736674667566766677667866796680668166826683668466856686668766886689669066916692669366946695669666976698669967006701670267036704670567066707670867096710671167126713671467156716671767186719672067216722672367246725672667276728672967306731673267336734673567366737673867396740674167426743674467456746674767486749675067516752675367546755675667576758675967606761676267636764676567666767676867696770677167726773677467756776677767786779678067816782678367846785678667876788678967906791679267936794679567966797679867996800680168026803680468056806680768086809681068116812681368146815681668176818681968206821682268236824682568266827682868296830683168326833683468356836683768386839684068416842 |
- [
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.36mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.05mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.62℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为400.74mg/L,管控值为600mg/L。\n出水SS存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "存在"
- },
- {
- "from": "human",
- "value": "状态:基本确认出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.54mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.37mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.21℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为398.11mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验比对,出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.49mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.10mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.64℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为400.26mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "不超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为0.03mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.29mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.80℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为401.30mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "不正常"
- },
- {
- "from": "human",
- "value": "状态:出水SS在线检测仪表不正常。\n解决方案:\n请使用如下排查方式进行:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.97mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.63mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.24℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为398.22mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.56mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.84mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.32℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为399.87mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.68mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.00mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.35℃。\n进水pH:当前值是6.95。\n进水TDS:当前值为398.09mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.15mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为320.26mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.61℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为400.88mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.81mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为320.06mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.39℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为398.36mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.06mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为318.51mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.95mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.77℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为399.86mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.82mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为465.63mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.38℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为401.39mg/L,管控值为600mg/L。\n进水总量与设计值的比较是小于设计值\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.01mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为463.56mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.92℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为401.11mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是大于但未超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.18mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为463.04mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.01℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为398.93mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.44mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.30mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.81℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为398.86mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分不高、浮渣也不多"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.37mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.98mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.48℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为398.08mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分高或浮渣多"
- },
- {
- "from": "human",
- "value": "状态:进水无机成分高或浮渣类多。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.28mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.90mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值2500mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.95mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.11℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为398.45mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有大于"
- },
- {
- "from": "human",
- "value": "状态:MLVSS/MLSS大于各厂稳态值。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.89mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.65mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.10℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为400.86mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.64mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.93mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为5.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.23℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为399.01mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:DO控制过高,曝气过渡。\n解决方案:\nDO控制过高,曝气过渡,污泥存在解絮,出水带泥,使得微生物活性下降,可采用以下方式解决:\n1、解决供风量过高导致的好氧段DO过高\n首先查看风机状态,尝试降低已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,可以通过放空阀进行气量放空。A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决由于生化池液位差异引起生化池气量分配不均导致的混合液回流DO过高\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.80mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.79mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.74℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为399.45mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.60mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.65mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值5100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.90℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为399.07mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:生化池污泥浓度过高。\n解决方案:\n由于污泥增值过快或排泥不及时等导致系统污泥浓度过高,使得微生物活性下降,可采用以下方式解决:\n1、进行工艺调整\n加大剩余污泥排放量,缩短污泥龄,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.69mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.88mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是19.00℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为401.43mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.81mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.53mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是6.04℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为400.50mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水水温偏低。\n解决方案:\n由于水温低于8℃,微生物活性明显降低,可采用以下方式解决:\n1、强化温降数据收集与分析,提前预警风险\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时(通过进水水温数据判断),加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n①合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n②适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(SS不超过150mg/L)情况下,也可控制在20~25天。\n3、解决污泥膨胀、老化、腐化、解絮等导致的出水带泥,SS不受控\n强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、腐化、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n4、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n5、短期内无法解决恢复\n及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.77mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.00mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.22℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为399.66mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.21mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.92mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.95mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.98℃。\n进水pH:当前值是16.53。\n进水TDS:当前值为401.33mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水pH异常。\n解决方案:\npH异常导致微生物活性下降,可采用以下方式解决:\n1、启动水质溯源,同步投加药剂调节pH,确保系统各生化段pH在合理范围内;\n2、解决高氨氮硝化反应过多消耗碱度或进水碱度降低导致系统缓冲液体系失衡\n①根据回流混合液硝酸盐浓度和缺氧池碱度核算后,投加工业碱调节pH。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.78mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.71mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.52℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为401.56mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.04mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.46mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.57℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为798.37mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "超出"
- },
- {
- "from": "human",
- "value": "状态:进水TDS超过管控值。\n解决方案:\n以进水TDS数据表征有毒物质,由于有毒物质进入系统导致微生物活性下降,可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争取第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力\n3、毒性小试实验方案\n将现有生化系统活性厌氧段污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下,开启六连搅拌器,缓慢搅拌,搅拌时间模拟厌氧段停留时间,每 2h 取样 1 次,按上述比例24h 换水 1 次(换水量为 50%),连续运行 72h,观察总磷去除效率,根据实验结果确定:① 探究污水对厌氧释磷的毒性抑制作用;② 探究解决当前生化池毒性抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,系统总磷去除率不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,总磷去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.81mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.80mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.14℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为398.68mg/L,管控值为600mg/L。\n出水SS存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "存在"
- },
- {
- "from": "human",
- "value": "状态:基本确认出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.04mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.32mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.07℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为399.19mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验比对,出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.59mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.37mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.05℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为400.61mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "不超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为-0.02mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.06mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.69℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为400.68mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "不正常"
- },
- {
- "from": "human",
- "value": "状态:出水SS在线检测仪表不正常。\n解决方案:\n请使用如下排查方式进行:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.60mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.67mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.35℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为400.41mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.69mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.78mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.37℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为401.06mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.51mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.01mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.16℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为399.49mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.20mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为320.58mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.14℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为400.55mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.22mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为320.87mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.22℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为399.29mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.41mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为318.04mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.95℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为401.87mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.08mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为464.11mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.41℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为398.31mg/L,管控值为600mg/L。\n进水总量与设计值的比较是小于设计值\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.95mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为465.26mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.61℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为401.75mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是大于但未超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.33mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为462.95mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.08℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为399.48mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.77mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.11mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.90℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为399.08mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分不高、浮渣也不多"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.39mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.91mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.83℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为400.47mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分高或浮渣多"
- },
- {
- "from": "human",
- "value": "状态:进水无机成分高或浮渣类多。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.48mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.53mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值2500mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.22℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为400.44mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有大于"
- },
- {
- "from": "human",
- "value": "状态:MLVSS/MLSS大于各厂稳态值。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.92mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.58mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.70℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为401.23mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.10mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.84mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为5.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.30℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为401.18mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:DO控制过高,曝气过渡。\n解决方案:\nDO控制过高,曝气过渡,污泥存在解絮,出水带泥,使得微生物活性下降,可采用以下方式解决:\n1、解决供风量过高导致的好氧段DO过高\n首先查看风机状态,尝试降低已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,可以通过放空阀进行气量放空。A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决由于生化池液位差异引起生化池气量分配不均导致的混合液回流DO过高\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.69mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.41mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.54℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为398.69mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.29mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.33mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值5100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.79℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为401.82mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:生化池污泥浓度过高。\n解决方案:\n由于污泥增值过快或排泥不及时等导致系统污泥浓度过高,使得微生物活性下降,可采用以下方式解决:\n1、进行工艺调整\n加大剩余污泥排放量,缩短污泥龄,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.01mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.26mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.31℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为400.59mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.11mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.20mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是5.96℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为399.15mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水水温偏低。\n解决方案:\n由于水温低于8℃,微生物活性明显降低,可采用以下方式解决:\n1、强化温降数据收集与分析,提前预警风险\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时(通过进水水温数据判断),加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n①合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n②适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(SS不超过150mg/L)情况下,也可控制在20~25天。\n3、解决污泥膨胀、老化、腐化、解絮等导致的出水带泥,SS不受控\n强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、腐化、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n4、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n5、短期内无法解决恢复\n及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.42mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.61mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.91℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为398.92mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.74mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.03mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.25℃。\n进水pH:当前值是17.71。\n进水TDS:当前值为400.66mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水pH异常。\n解决方案:\npH异常导致微生物活性下降,可采用以下方式解决:\n1、启动水质溯源,同步投加药剂调节pH,确保系统各生化段pH在合理范围内;\n2、解决高氨氮硝化反应过多消耗碱度或进水碱度降低导致系统缓冲液体系失衡\n①根据回流混合液硝酸盐浓度和缺氧池碱度核算后,投加工业碱调节pH。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.37mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.58mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.28℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为401.43mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.63mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.44mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.65℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为798.81mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "超出"
- },
- {
- "from": "human",
- "value": "状态:进水TDS超过管控值。\n解决方案:\n以进水TDS数据表征有毒物质,由于有毒物质进入系统导致微生物活性下降,可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争取第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力\n3、毒性小试实验方案\n将现有生化系统活性厌氧段污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下,开启六连搅拌器,缓慢搅拌,搅拌时间模拟厌氧段停留时间,每 2h 取样 1 次,按上述比例24h 换水 1 次(换水量为 50%),连续运行 72h,观察总磷去除效率,根据实验结果确定:① 探究污水对厌氧释磷的毒性抑制作用;② 探究解决当前生化池毒性抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,系统总磷去除率不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,总磷去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.89mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.85mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.05mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.11℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为401.13mg/L,管控值为600mg/L。\n出水SS存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "存在"
- },
- {
- "from": "human",
- "value": "状态:基本确认出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.08mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.70mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.97℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为401.72mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验比对,出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.48mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.30mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.54℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为401.39mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "不超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为0.01mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.64mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.30℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为399.69mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "不正常"
- },
- {
- "from": "human",
- "value": "状态:出水SS在线检测仪表不正常。\n解决方案:\n请使用如下排查方式进行:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.68mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.42mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.70℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为399.44mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.14mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.21mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.28℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为398.66mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.75mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.11mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.95mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.49℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为398.35mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.94mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为321.05mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.57℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为401.25mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.44mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为318.45mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.64℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为401.24mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.94mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为320.37mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.73℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为398.14mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.99mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为462.95mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.65℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为401.99mg/L,管控值为600mg/L。\n进水总量与设计值的比较是小于设计值\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.38mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为463.92mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.38℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为401.80mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是大于但未超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.19mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为462.57mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.43℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为400.78mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.93mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.14mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.21℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为400.03mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分不高、浮渣也不多"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.76mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.89mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.71℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为399.74mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分高或浮渣多"
- },
- {
- "from": "human",
- "value": "状态:进水无机成分高或浮渣类多。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.59mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.78mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值2500mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.71℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为401.94mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有大于"
- },
- {
- "from": "human",
- "value": "状态:MLVSS/MLSS大于各厂稳态值。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.43mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.00mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.41℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为399.69mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.79mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.47mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为5.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.06℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为401.23mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:DO控制过高,曝气过渡。\n解决方案:\nDO控制过高,曝气过渡,污泥存在解絮,出水带泥,使得微生物活性下降,可采用以下方式解决:\n1、解决供风量过高导致的好氧段DO过高\n首先查看风机状态,尝试降低已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,可以通过放空阀进行气量放空。A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决由于生化池液位差异引起生化池气量分配不均导致的混合液回流DO过高\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.10mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.25mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.68℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为398.04mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.19mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.79mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值5100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.99℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为400.81mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:生化池污泥浓度过高。\n解决方案:\n由于污泥增值过快或排泥不及时等导致系统污泥浓度过高,使得微生物活性下降,可采用以下方式解决:\n1、进行工艺调整\n加大剩余污泥排放量,缩短污泥龄,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.59mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.17mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.44℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为399.84mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.62mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.88mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是6.00℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为398.91mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水水温偏低。\n解决方案:\n由于水温低于8℃,微生物活性明显降低,可采用以下方式解决:\n1、强化温降数据收集与分析,提前预警风险\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时(通过进水水温数据判断),加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n①合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n②适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(SS不超过150mg/L)情况下,也可控制在20~25天。\n3、解决污泥膨胀、老化、腐化、解絮等导致的出水带泥,SS不受控\n强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、腐化、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n4、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n5、短期内无法解决恢复\n及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.47mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.78mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.92℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为401.82mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.21mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.57mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.25℃。\n进水pH:当前值是16.66。\n进水TDS:当前值为401.45mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水pH异常。\n解决方案:\npH异常导致微生物活性下降,可采用以下方式解决:\n1、启动水质溯源,同步投加药剂调节pH,确保系统各生化段pH在合理范围内;\n2、解决高氨氮硝化反应过多消耗碱度或进水碱度降低导致系统缓冲液体系失衡\n①根据回流混合液硝酸盐浓度和缺氧池碱度核算后,投加工业碱调节pH。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.09mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.51mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.13℃。\n进水pH:当前值是6.95。\n进水TDS:当前值为398.97mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.57mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.96mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.60℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为798.05mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "超出"
- },
- {
- "from": "human",
- "value": "状态:进水TDS超过管控值。\n解决方案:\n以进水TDS数据表征有毒物质,由于有毒物质进入系统导致微生物活性下降,可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争取第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力\n3、毒性小试实验方案\n将现有生化系统活性厌氧段污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下,开启六连搅拌器,缓慢搅拌,搅拌时间模拟厌氧段停留时间,每 2h 取样 1 次,按上述比例24h 换水 1 次(换水量为 50%),连续运行 72h,观察总磷去除效率,根据实验结果确定:① 探究污水对厌氧释磷的毒性抑制作用;② 探究解决当前生化池毒性抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,系统总磷去除率不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,总磷去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.07mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.94mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.40℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为399.32mg/L,管控值为600mg/L。\n出水SS存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "存在"
- },
- {
- "from": "human",
- "value": "状态:基本确认出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.48mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.16mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.79℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为398.73mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验比对,出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.68mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.12mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.23℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为398.44mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "不超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为-0.02mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.36mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.95mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.14℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为399.82mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "不正常"
- },
- {
- "from": "human",
- "value": "状态:出水SS在线检测仪表不正常。\n解决方案:\n请使用如下排查方式进行:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.91mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.11mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.04℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为400.33mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.69mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.58mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.97℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为398.03mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.93mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.47mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.81℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为398.52mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.01mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为320.71mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.39℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为398.05mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.94mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为321.45mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.52℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为400.95mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.58mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为320.97mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.95mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.05℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为400.13mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.90mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为463.30mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.46℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为399.85mg/L,管控值为600mg/L。\n进水总量与设计值的比较是小于设计值\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.93mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为464.94mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.68℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为398.43mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是大于但未超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.19mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为464.63mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.65℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为399.35mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.49mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.75mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.05℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为401.88mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分不高、浮渣也不多"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.42mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.29mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.85℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为400.87mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分高或浮渣多"
- },
- {
- "from": "human",
- "value": "状态:进水无机成分高或浮渣类多。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.97mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.81mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值2500mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.64℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为401.43mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有大于"
- },
- {
- "from": "human",
- "value": "状态:MLVSS/MLSS大于各厂稳态值。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.60mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.91mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.37℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为399.01mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.11mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.48mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为5.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.01℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为401.02mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:DO控制过高,曝气过渡。\n解决方案:\nDO控制过高,曝气过渡,污泥存在解絮,出水带泥,使得微生物活性下降,可采用以下方式解决:\n1、解决供风量过高导致的好氧段DO过高\n首先查看风机状态,尝试降低已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,可以通过放空阀进行气量放空。A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决由于生化池液位差异引起生化池气量分配不均导致的混合液回流DO过高\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.02mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.56mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.77℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为401.06mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.96mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.06mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值5100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.59℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为400.59mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:生化池污泥浓度过高。\n解决方案:\n由于污泥增值过快或排泥不及时等导致系统污泥浓度过高,使得微生物活性下降,可采用以下方式解决:\n1、进行工艺调整\n加大剩余污泥排放量,缩短污泥龄,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.10mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.97mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.95mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.39℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为401.79mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.80mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.14mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是5.98℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为398.99mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水水温偏低。\n解决方案:\n由于水温低于8℃,微生物活性明显降低,可采用以下方式解决:\n1、强化温降数据收集与分析,提前预警风险\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时(通过进水水温数据判断),加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n①合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n②适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(SS不超过150mg/L)情况下,也可控制在20~25天。\n3、解决污泥膨胀、老化、腐化、解絮等导致的出水带泥,SS不受控\n强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、腐化、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n4、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n5、短期内无法解决恢复\n及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.57mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.62mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.32℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为400.22mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.96mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.03mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.98℃。\n进水pH:当前值是17.39。\n进水TDS:当前值为400.61mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水pH异常。\n解决方案:\npH异常导致微生物活性下降,可采用以下方式解决:\n1、启动水质溯源,同步投加药剂调节pH,确保系统各生化段pH在合理范围内;\n2、解决高氨氮硝化反应过多消耗碱度或进水碱度降低导致系统缓冲液体系失衡\n①根据回流混合液硝酸盐浓度和缺氧池碱度核算后,投加工业碱调节pH。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.74mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.41mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.32℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为401.38mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.62mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.01mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.90℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为799.05mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "超出"
- },
- {
- "from": "human",
- "value": "状态:进水TDS超过管控值。\n解决方案:\n以进水TDS数据表征有毒物质,由于有毒物质进入系统导致微生物活性下降,可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争取第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力\n3、毒性小试实验方案\n将现有生化系统活性厌氧段污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下,开启六连搅拌器,缓慢搅拌,搅拌时间模拟厌氧段停留时间,每 2h 取样 1 次,按上述比例24h 换水 1 次(换水量为 50%),连续运行 72h,观察总磷去除效率,根据实验结果确定:① 探究污水对厌氧释磷的毒性抑制作用;② 探究解决当前生化池毒性抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,系统总磷去除率不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,总磷去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.19mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.98mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.78℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为400.29mg/L,管控值为600mg/L。\n出水SS存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "存在"
- },
- {
- "from": "human",
- "value": "状态:基本确认出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.08mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.86mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.82℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为400.55mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验比对,出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.89mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.19mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.44℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为400.27mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "不超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为0.01mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.38mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.17℃。\n进水pH:当前值是6.95。\n进水TDS:当前值为400.02mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "不正常"
- },
- {
- "from": "human",
- "value": "状态:出水SS在线检测仪表不正常。\n解决方案:\n请使用如下排查方式进行:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.11mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.74mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.85℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为401.13mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.26mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.83mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.28℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为398.40mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.98mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.63mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.70℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为399.78mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.86mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为318.20mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.93℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为399.06mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.70mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为319.02mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.42℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为401.85mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.65mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为318.31mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.95mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.97℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为400.44mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.65mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为465.81mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.85℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为401.10mg/L,管控值为600mg/L。\n进水总量与设计值的比较是小于设计值\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.72mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为464.89mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.78℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为401.69mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是大于但未超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.76mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为465.53mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.03℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为400.85mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.55mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.11mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.12℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为399.56mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分不高、浮渣也不多"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.96mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.35mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.66℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为399.31mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分高或浮渣多"
- },
- {
- "from": "human",
- "value": "状态:进水无机成分高或浮渣类多。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.85mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.20mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值2500mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.84℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为400.13mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有大于"
- },
- {
- "from": "human",
- "value": "状态:MLVSS/MLSS大于各厂稳态值。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.55mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.09mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.35℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为398.05mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.44mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.07mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为5.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.90℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为400.86mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:DO控制过高,曝气过渡。\n解决方案:\nDO控制过高,曝气过渡,污泥存在解絮,出水带泥,使得微生物活性下降,可采用以下方式解决:\n1、解决供风量过高导致的好氧段DO过高\n首先查看风机状态,尝试降低已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,可以通过放空阀进行气量放空。A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决由于生化池液位差异引起生化池气量分配不均导致的混合液回流DO过高\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.01mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.29mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.86℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为401.05mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.15mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.29mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值5100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.87℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为399.02mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:生化池污泥浓度过高。\n解决方案:\n由于污泥增值过快或排泥不及时等导致系统污泥浓度过高,使得微生物活性下降,可采用以下方式解决:\n1、进行工艺调整\n加大剩余污泥排放量,缩短污泥龄,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.35mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.86mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.78℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为398.98mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.14mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.10mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是5.97℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为398.74mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水水温偏低。\n解决方案:\n由于水温低于8℃,微生物活性明显降低,可采用以下方式解决:\n1、强化温降数据收集与分析,提前预警风险\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时(通过进水水温数据判断),加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n①合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n②适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(SS不超过150mg/L)情况下,也可控制在20~25天。\n3、解决污泥膨胀、老化、腐化、解絮等导致的出水带泥,SS不受控\n强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、腐化、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n4、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n5、短期内无法解决恢复\n及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.96mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.32mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.95mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.04℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为399.69mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.26mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.95mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.38℃。\n进水pH:当前值是16.43。\n进水TDS:当前值为398.45mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水pH异常。\n解决方案:\npH异常导致微生物活性下降,可采用以下方式解决:\n1、启动水质溯源,同步投加药剂调节pH,确保系统各生化段pH在合理范围内;\n2、解决高氨氮硝化反应过多消耗碱度或进水碱度降低导致系统缓冲液体系失衡\n①根据回流混合液硝酸盐浓度和缺氧池碱度核算后,投加工业碱调节pH。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.52mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.60mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.41℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为401.93mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.99mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.67mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.31℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为799.32mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "超出"
- },
- {
- "from": "human",
- "value": "状态:进水TDS超过管控值。\n解决方案:\n以进水TDS数据表征有毒物质,由于有毒物质进入系统导致微生物活性下降,可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争取第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力\n3、毒性小试实验方案\n将现有生化系统活性厌氧段污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下,开启六连搅拌器,缓慢搅拌,搅拌时间模拟厌氧段停留时间,每 2h 取样 1 次,按上述比例24h 换水 1 次(换水量为 50%),连续运行 72h,观察总磷去除效率,根据实验结果确定:① 探究污水对厌氧释磷的毒性抑制作用;② 探究解决当前生化池毒性抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,系统总磷去除率不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,总磷去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.50mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.94mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.19℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为401.94mg/L,管控值为600mg/L。\n出水SS存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "存在"
- },
- {
- "from": "human",
- "value": "状态:基本确认出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.31mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.35mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.05mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.75℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为401.87mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验比对,出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.66mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.44mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.11℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为400.21mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "不超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为0.01mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.66mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.97℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为400.41mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "不正常"
- },
- {
- "from": "human",
- "value": "状态:出水SS在线检测仪表不正常。\n解决方案:\n请使用如下排查方式进行:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.16mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.08mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.38℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为400.06mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.04mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.05mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.54℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为400.37mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.57mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.45mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.58℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为398.23mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.97mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为318.13mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.90℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为401.15mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.42mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为321.82mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.95℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为398.04mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.66mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为319.27mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.86℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为399.71mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.12mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为465.70mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.75℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为401.76mg/L,管控值为600mg/L。\n进水总量与设计值的比较是小于设计值\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.97mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为462.27mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.77℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为398.97mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是大于但未超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.97mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为465.51mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.95mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.07℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为401.27mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.00mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.27mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.47℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为401.12mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分不高、浮渣也不多"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.16mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.33mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.28℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为401.13mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分高或浮渣多"
- },
- {
- "from": "human",
- "value": "状态:进水无机成分高或浮渣类多。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.81mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.20mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值2500mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.69℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为398.37mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有大于"
- },
- {
- "from": "human",
- "value": "状态:MLVSS/MLSS大于各厂稳态值。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.59mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.54mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.39℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为399.16mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.92mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.56mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为5.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.59℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为400.17mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:DO控制过高,曝气过渡。\n解决方案:\nDO控制过高,曝气过渡,污泥存在解絮,出水带泥,使得微生物活性下降,可采用以下方式解决:\n1、解决供风量过高导致的好氧段DO过高\n首先查看风机状态,尝试降低已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,可以通过放空阀进行气量放空。A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决由于生化池液位差异引起生化池气量分配不均导致的混合液回流DO过高\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.02mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.86mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.77℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为400.39mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.38mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.88mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值5100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.43℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为398.29mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:生化池污泥浓度过高。\n解决方案:\n由于污泥增值过快或排泥不及时等导致系统污泥浓度过高,使得微生物活性下降,可采用以下方式解决:\n1、进行工艺调整\n加大剩余污泥排放量,缩短污泥龄,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.99mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.54mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.12℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为401.89mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.54mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.72mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.05mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是5.97℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为400.22mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水水温偏低。\n解决方案:\n由于水温低于8℃,微生物活性明显降低,可采用以下方式解决:\n1、强化温降数据收集与分析,提前预警风险\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时(通过进水水温数据判断),加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n①合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n②适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(SS不超过150mg/L)情况下,也可控制在20~25天。\n3、解决污泥膨胀、老化、腐化、解絮等导致的出水带泥,SS不受控\n强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、腐化、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n4、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n5、短期内无法解决恢复\n及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.00mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.13mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.48℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为398.74mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.09mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.63mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.30℃。\n进水pH:当前值是16.72。\n进水TDS:当前值为401.52mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水pH异常。\n解决方案:\npH异常导致微生物活性下降,可采用以下方式解决:\n1、启动水质溯源,同步投加药剂调节pH,确保系统各生化段pH在合理范围内;\n2、解决高氨氮硝化反应过多消耗碱度或进水碱度降低导致系统缓冲液体系失衡\n①根据回流混合液硝酸盐浓度和缺氧池碱度核算后,投加工业碱调节pH。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.86mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.66mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.39℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为398.30mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.56mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.27mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.73℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为799.84mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "超出"
- },
- {
- "from": "human",
- "value": "状态:进水TDS超过管控值。\n解决方案:\n以进水TDS数据表征有毒物质,由于有毒物质进入系统导致微生物活性下降,可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争取第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力\n3、毒性小试实验方案\n将现有生化系统活性厌氧段污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下,开启六连搅拌器,缓慢搅拌,搅拌时间模拟厌氧段停留时间,每 2h 取样 1 次,按上述比例24h 换水 1 次(换水量为 50%),连续运行 72h,观察总磷去除效率,根据实验结果确定:① 探究污水对厌氧释磷的毒性抑制作用;② 探究解决当前生化池毒性抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,系统总磷去除率不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,总磷去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.13mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.00mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.70℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为399.22mg/L,管控值为600mg/L。\n出水SS存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "存在"
- },
- {
- "from": "human",
- "value": "状态:基本确认出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.55mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.05mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.75℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为398.15mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验比对,出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.83mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.99mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.07℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为399.61mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "不超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为0.03mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.18mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.85℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为398.62mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "不正常"
- },
- {
- "from": "human",
- "value": "状态:出水SS在线检测仪表不正常。\n解决方案:\n请使用如下排查方式进行:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.45mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.37mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.78℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为400.50mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.49mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.08mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.11℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为401.09mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.62mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.65mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.49℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为399.86mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.64mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为319.00mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.55℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为400.94mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.42mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为319.56mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.21℃。\n进水pH:当前值是6.95。\n进水TDS:当前值为398.71mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.82mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为321.08mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.44℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为399.80mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.30mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为465.17mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.90℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为400.28mg/L,管控值为600mg/L。\n进水总量与设计值的比较是小于设计值\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.20mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为462.63mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.82℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为398.11mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是大于但未超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.80mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为465.22mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.95mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.26℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为398.31mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.31mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.67mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.72℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为398.97mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分不高、浮渣也不多"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.67mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.10mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.88℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为401.20mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分高或浮渣多"
- },
- {
- "from": "human",
- "value": "状态:进水无机成分高或浮渣类多。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.25mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.76mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值2500mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.47℃。\n进水pH:当前值是6.95。\n进水TDS:当前值为398.81mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有大于"
- },
- {
- "from": "human",
- "value": "状态:MLVSS/MLSS大于各厂稳态值。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.71mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.42mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.56℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为398.06mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.80mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.15mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为5.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.01℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为400.51mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:DO控制过高,曝气过渡。\n解决方案:\nDO控制过高,曝气过渡,污泥存在解絮,出水带泥,使得微生物活性下降,可采用以下方式解决:\n1、解决供风量过高导致的好氧段DO过高\n首先查看风机状态,尝试降低已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,可以通过放空阀进行气量放空。A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决由于生化池液位差异引起生化池气量分配不均导致的混合液回流DO过高\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.77mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.24mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.46℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为398.30mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.20mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.70mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值5100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.50℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为398.02mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:生化池污泥浓度过高。\n解决方案:\n由于污泥增值过快或排泥不及时等导致系统污泥浓度过高,使得微生物活性下降,可采用以下方式解决:\n1、进行工艺调整\n加大剩余污泥排放量,缩短污泥龄,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.36mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.24mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.19℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为399.90mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.78mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.01mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是6.00℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为400.61mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水水温偏低。\n解决方案:\n由于水温低于8℃,微生物活性明显降低,可采用以下方式解决:\n1、强化温降数据收集与分析,提前预警风险\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时(通过进水水温数据判断),加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n①合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n②适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(SS不超过150mg/L)情况下,也可控制在20~25天。\n3、解决污泥膨胀、老化、腐化、解絮等导致的出水带泥,SS不受控\n强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、腐化、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n4、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n5、短期内无法解决恢复\n及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.29mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.19mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.05mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.18℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为398.85mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.99mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.62mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.91℃。\n进水pH:当前值是17.94。\n进水TDS:当前值为400.88mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水pH异常。\n解决方案:\npH异常导致微生物活性下降,可采用以下方式解决:\n1、启动水质溯源,同步投加药剂调节pH,确保系统各生化段pH在合理范围内;\n2、解决高氨氮硝化反应过多消耗碱度或进水碱度降低导致系统缓冲液体系失衡\n①根据回流混合液硝酸盐浓度和缺氧池碱度核算后,投加工业碱调节pH。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.30mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.41mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.16℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为398.96mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.21mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.56mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.91℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为798.16mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "超出"
- },
- {
- "from": "human",
- "value": "状态:进水TDS超过管控值。\n解决方案:\n以进水TDS数据表征有毒物质,由于有毒物质进入系统导致微生物活性下降,可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争取第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力\n3、毒性小试实验方案\n将现有生化系统活性厌氧段污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下,开启六连搅拌器,缓慢搅拌,搅拌时间模拟厌氧段停留时间,每 2h 取样 1 次,按上述比例24h 换水 1 次(换水量为 50%),连续运行 72h,观察总磷去除效率,根据实验结果确定:① 探究污水对厌氧释磷的毒性抑制作用;② 探究解决当前生化池毒性抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,系统总磷去除率不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,总磷去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.67mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.63mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.05℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为400.25mg/L,管控值为600mg/L。\n出水SS存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "存在"
- },
- {
- "from": "human",
- "value": "状态:基本确认出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.13mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.67mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.20℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为400.02mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验比对,出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.25mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.96mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.91℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为400.15mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "不超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为0.02mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.48mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.85℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为401.56mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "不正常"
- },
- {
- "from": "human",
- "value": "状态:出水SS在线检测仪表不正常。\n解决方案:\n请使用如下排查方式进行:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.63mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.33mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.92℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为400.73mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.60mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.85mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.05mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.79℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为398.48mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.85mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.33mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.53℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为401.00mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.54mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为320.02mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.40℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为401.46mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.32mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为318.50mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.88℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为398.17mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.72mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为319.25mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.50℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为400.87mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.45mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为464.10mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.70℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为401.72mg/L,管控值为600mg/L。\n进水总量与设计值的比较是小于设计值\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.65mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为465.01mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.28℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为401.63mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是大于但未超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.24mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为462.86mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.51℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为398.60mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.11mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.40mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.29℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为400.17mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分不高、浮渣也不多"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.70mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.86mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.70℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为401.41mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分高或浮渣多"
- },
- {
- "from": "human",
- "value": "状态:进水无机成分高或浮渣类多。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.92mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.26mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值2500mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.45℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为401.62mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有大于"
- },
- {
- "from": "human",
- "value": "状态:MLVSS/MLSS大于各厂稳态值。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.24mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.23mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.34℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为399.64mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.25mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.61mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为5.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.24℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为398.21mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:DO控制过高,曝气过渡。\n解决方案:\nDO控制过高,曝气过渡,污泥存在解絮,出水带泥,使得微生物活性下降,可采用以下方式解决:\n1、解决供风量过高导致的好氧段DO过高\n首先查看风机状态,尝试降低已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,可以通过放空阀进行气量放空。A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决由于生化池液位差异引起生化池气量分配不均导致的混合液回流DO过高\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.55mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.48mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.79℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为398.25mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.05mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.51mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值5100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.27℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为401.91mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:生化池污泥浓度过高。\n解决方案:\n由于污泥增值过快或排泥不及时等导致系统污泥浓度过高,使得微生物活性下降,可采用以下方式解决:\n1、进行工艺调整\n加大剩余污泥排放量,缩短污泥龄,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.45mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.22mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.97℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为399.66mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.04mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.66mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是6.03℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为400.91mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水水温偏低。\n解决方案:\n由于水温低于8℃,微生物活性明显降低,可采用以下方式解决:\n1、强化温降数据收集与分析,提前预警风险\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时(通过进水水温数据判断),加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n①合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n②适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(SS不超过150mg/L)情况下,也可控制在20~25天。\n3、解决污泥膨胀、老化、腐化、解絮等导致的出水带泥,SS不受控\n强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、腐化、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n4、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n5、短期内无法解决恢复\n及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.90mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.66mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.39℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为400.42mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.97mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.81mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.26℃。\n进水pH:当前值是17.10。\n进水TDS:当前值为400.01mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水pH异常。\n解决方案:\npH异常导致微生物活性下降,可采用以下方式解决:\n1、启动水质溯源,同步投加药剂调节pH,确保系统各生化段pH在合理范围内;\n2、解决高氨氮硝化反应过多消耗碱度或进水碱度降低导致系统缓冲液体系失衡\n①根据回流混合液硝酸盐浓度和缺氧池碱度核算后,投加工业碱调节pH。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.40mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.80mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.77℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为401.26mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.89mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.66mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.12℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为799.44mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "超出"
- },
- {
- "from": "human",
- "value": "状态:进水TDS超过管控值。\n解决方案:\n以进水TDS数据表征有毒物质,由于有毒物质进入系统导致微生物活性下降,可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争取第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力\n3、毒性小试实验方案\n将现有生化系统活性厌氧段污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下,开启六连搅拌器,缓慢搅拌,搅拌时间模拟厌氧段停留时间,每 2h 取样 1 次,按上述比例24h 换水 1 次(换水量为 50%),连续运行 72h,观察总磷去除效率,根据实验结果确定:① 探究污水对厌氧释磷的毒性抑制作用;② 探究解决当前生化池毒性抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,系统总磷去除率不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,总磷去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.15mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.97mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.73℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为401.47mg/L,管控值为600mg/L。\n出水SS存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "存在"
- },
- {
- "from": "human",
- "value": "状态:基本确认出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.78mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.51mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.62℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为401.31mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验比对,出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.16mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.29mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.95℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为399.56mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "不超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为-0.05mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.59mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.92℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为400.19mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "不正常"
- },
- {
- "from": "human",
- "value": "状态:出水SS在线检测仪表不正常。\n解决方案:\n请使用如下排查方式进行:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.14mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.44mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.99℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为399.49mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.42mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.32mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.97℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为399.35mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.23mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.53mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.80℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为399.33mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.98mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为319.01mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.78℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为401.02mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.93mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为321.63mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.74℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为399.96mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.61mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为319.32mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.67℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为400.88mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.36mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为463.73mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.41℃。\n进水pH:当前值是6.95。\n进水TDS:当前值为399.08mg/L,管控值为600mg/L。\n进水总量与设计值的比较是小于设计值\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.61mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为462.02mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.70℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为398.26mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是大于但未超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.54mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为462.23mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.30℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为400.76mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.23mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.10mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.15℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为399.68mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分不高、浮渣也不多"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.32mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.34mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.72℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为400.92mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分高或浮渣多"
- },
- {
- "from": "human",
- "value": "状态:进水无机成分高或浮渣类多。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.57mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.55mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值2500mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.67℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为398.45mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有大于"
- },
- {
- "from": "human",
- "value": "状态:MLVSS/MLSS大于各厂稳态值。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.65mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.91mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.16℃。\n进水pH:当前值是6.95。\n进水TDS:当前值为399.82mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.31mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.38mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.95mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为5.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.54℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为399.23mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:DO控制过高,曝气过渡。\n解决方案:\nDO控制过高,曝气过渡,污泥存在解絮,出水带泥,使得微生物活性下降,可采用以下方式解决:\n1、解决供风量过高导致的好氧段DO过高\n首先查看风机状态,尝试降低已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,可以通过放空阀进行气量放空。A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决由于生化池液位差异引起生化池气量分配不均导致的混合液回流DO过高\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.51mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.92mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.69℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为401.34mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.33mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.48mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值5100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.15℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为398.93mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:生化池污泥浓度过高。\n解决方案:\n由于污泥增值过快或排泥不及时等导致系统污泥浓度过高,使得微生物活性下降,可采用以下方式解决:\n1、进行工艺调整\n加大剩余污泥排放量,缩短污泥龄,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.98mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.96mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.89℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为398.21mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.72mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.65mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是5.95℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为399.75mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水水温偏低。\n解决方案:\n由于水温低于8℃,微生物活性明显降低,可采用以下方式解决:\n1、强化温降数据收集与分析,提前预警风险\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时(通过进水水温数据判断),加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n①合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n②适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(SS不超过150mg/L)情况下,也可控制在20~25天。\n3、解决污泥膨胀、老化、腐化、解絮等导致的出水带泥,SS不受控\n强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、腐化、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n4、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n5、短期内无法解决恢复\n及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.37mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.70mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.66℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为399.83mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.53mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.51mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.74℃。\n进水pH:当前值是17.13。\n进水TDS:当前值为399.72mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水pH异常。\n解决方案:\npH异常导致微生物活性下降,可采用以下方式解决:\n1、启动水质溯源,同步投加药剂调节pH,确保系统各生化段pH在合理范围内;\n2、解决高氨氮硝化反应过多消耗碱度或进水碱度降低导致系统缓冲液体系失衡\n①根据回流混合液硝酸盐浓度和缺氧池碱度核算后,投加工业碱调节pH。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.33mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.63mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.45℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为400.67mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.92mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.25mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.60℃。\n进水pH:当前值是6.95。\n进水TDS:当前值为799.39mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "超出"
- },
- {
- "from": "human",
- "value": "状态:进水TDS超过管控值。\n解决方案:\n以进水TDS数据表征有毒物质,由于有毒物质进入系统导致微生物活性下降,可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争取第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力\n3、毒性小试实验方案\n将现有生化系统活性厌氧段污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下,开启六连搅拌器,缓慢搅拌,搅拌时间模拟厌氧段停留时间,每 2h 取样 1 次,按上述比例24h 换水 1 次(换水量为 50%),连续运行 72h,观察总磷去除效率,根据实验结果确定:① 探究污水对厌氧释磷的毒性抑制作用;② 探究解决当前生化池毒性抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,系统总磷去除率不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,总磷去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.95mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.17mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.89℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为398.37mg/L,管控值为600mg/L。\n出水SS存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "存在"
- },
- {
- "from": "human",
- "value": "状态:基本确认出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.12mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.13mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.46℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为399.34mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验比对,出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.26mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.66mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.94℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为399.13mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "不超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为-0.02mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.33mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.09℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为400.83mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "不正常"
- },
- {
- "from": "human",
- "value": "状态:出水SS在线检测仪表不正常。\n解决方案:\n请使用如下排查方式进行:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.23mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.10mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.05mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.55℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为401.07mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.30mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.02mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.01℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为399.34mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.30mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.89mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.83℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为400.18mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.74mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为320.12mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.95mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.53℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为400.29mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.23mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为321.23mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.32℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为399.82mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.29mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为321.02mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.93℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为400.73mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.75mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为463.47mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.02℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为399.23mg/L,管控值为600mg/L。\n进水总量与设计值的比较是小于设计值\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.36mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为463.93mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.66℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为398.12mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是大于但未超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.99mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为462.98mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.67℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为401.07mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.07mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.95mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.62℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为398.32mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分不高、浮渣也不多"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.01mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.09mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.20℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为401.70mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分高或浮渣多"
- },
- {
- "from": "human",
- "value": "状态:进水无机成分高或浮渣类多。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.06mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.63mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值2500mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.67℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为399.43mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有大于"
- },
- {
- "from": "human",
- "value": "状态:MLVSS/MLSS大于各厂稳态值。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.60mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.79mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.94℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为399.91mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.54mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.14mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为5.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.20℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为399.02mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:DO控制过高,曝气过渡。\n解决方案:\nDO控制过高,曝气过渡,污泥存在解絮,出水带泥,使得微生物活性下降,可采用以下方式解决:\n1、解决供风量过高导致的好氧段DO过高\n首先查看风机状态,尝试降低已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,可以通过放空阀进行气量放空。A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决由于生化池液位差异引起生化池气量分配不均导致的混合液回流DO过高\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.37mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.88mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.39℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为401.92mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.11mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.01mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值5100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.31℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为398.21mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:生化池污泥浓度过高。\n解决方案:\n由于污泥增值过快或排泥不及时等导致系统污泥浓度过高,使得微生物活性下降,可采用以下方式解决:\n1、进行工艺调整\n加大剩余污泥排放量,缩短污泥龄,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.80mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.10mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.09℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为400.26mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.15mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.75mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是5.98℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为398.90mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水水温偏低。\n解决方案:\n由于水温低于8℃,微生物活性明显降低,可采用以下方式解决:\n1、强化温降数据收集与分析,提前预警风险\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时(通过进水水温数据判断),加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n①合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n②适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(SS不超过150mg/L)情况下,也可控制在20~25天。\n3、解决污泥膨胀、老化、腐化、解絮等导致的出水带泥,SS不受控\n强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、腐化、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n4、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n5、短期内无法解决恢复\n及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.49mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.44mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.95mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.67℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为401.90mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.06mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.55mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.49℃。\n进水pH:当前值是16.58。\n进水TDS:当前值为398.28mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水pH异常。\n解决方案:\npH异常导致微生物活性下降,可采用以下方式解决:\n1、启动水质溯源,同步投加药剂调节pH,确保系统各生化段pH在合理范围内;\n2、解决高氨氮硝化反应过多消耗碱度或进水碱度降低导致系统缓冲液体系失衡\n①根据回流混合液硝酸盐浓度和缺氧池碱度核算后,投加工业碱调节pH。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.09mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.44mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.09℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为400.91mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.59mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.26mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.97℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为800.74mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "超出"
- },
- {
- "from": "human",
- "value": "状态:进水TDS超过管控值。\n解决方案:\n以进水TDS数据表征有毒物质,由于有毒物质进入系统导致微生物活性下降,可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争取第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力\n3、毒性小试实验方案\n将现有生化系统活性厌氧段污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下,开启六连搅拌器,缓慢搅拌,搅拌时间模拟厌氧段停留时间,每 2h 取样 1 次,按上述比例24h 换水 1 次(换水量为 50%),连续运行 72h,观察总磷去除效率,根据实验结果确定:① 探究污水对厌氧释磷的毒性抑制作用;② 探究解决当前生化池毒性抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,系统总磷去除率不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,总磷去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.26mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.59mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.97℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为399.45mg/L,管控值为600mg/L。\n出水SS存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "存在"
- },
- {
- "from": "human",
- "value": "状态:基本确认出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.74mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.66mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.83℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为400.76mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验比对,出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.20mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.74mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.48℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为399.04mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "不超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为-0.04mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.16mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.90℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为400.99mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "不正常"
- },
- {
- "from": "human",
- "value": "状态:出水SS在线检测仪表不正常。\n解决方案:\n请使用如下排查方式进行:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.41mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.72mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.26℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为398.93mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.50mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.00mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.46℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为398.56mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.43mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.62mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.36℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为401.12mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.92mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为318.67mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.93℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为398.09mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.91mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为318.14mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.01℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为399.44mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.61mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为318.53mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.21℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为400.67mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.49mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为465.49mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.73℃。\n进水pH:当前值是6.95。\n进水TDS:当前值为398.40mg/L,管控值为600mg/L。\n进水总量与设计值的比较是小于设计值\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.42mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为464.80mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.81℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为399.33mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是大于但未超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.56mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为463.50mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.53℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为401.29mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.33mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.99mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.97℃。\n进水pH:当前值是7.05。\n进水TDS:当前值为400.51mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分不高、浮渣也不多"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.96mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.05mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.54℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为398.98mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分高或浮渣多"
- },
- {
- "from": "human",
- "value": "状态:进水无机成分高或浮渣类多。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.83mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.86mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值2500mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.60℃。\n进水pH:当前值是7.01。\n进水TDS:当前值为401.50mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有大于"
- },
- {
- "from": "human",
- "value": "状态:MLVSS/MLSS大于各厂稳态值。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.42mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.11mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.43℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为401.15mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.30mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.88mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为5.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.77℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为398.63mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:DO控制过高,曝气过渡。\n解决方案:\nDO控制过高,曝气过渡,污泥存在解絮,出水带泥,使得微生物活性下降,可采用以下方式解决:\n1、解决供风量过高导致的好氧段DO过高\n首先查看风机状态,尝试降低已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,可以通过放空阀进行气量放空。A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决由于生化池液位差异引起生化池气量分配不均导致的混合液回流DO过高\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.50mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.91mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.11℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为399.88mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.62mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.49mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值5100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.51℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为401.82mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:生化池污泥浓度过高。\n解决方案:\n由于污泥增值过快或排泥不及时等导致系统污泥浓度过高,使得微生物活性下降,可采用以下方式解决:\n1、进行工艺调整\n加大剩余污泥排放量,缩短污泥龄,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.83mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.02mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.22℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为400.69mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.50mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.73mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是6.03℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为401.04mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水水温偏低。\n解决方案:\n由于水温低于8℃,微生物活性明显降低,可采用以下方式解决:\n1、强化温降数据收集与分析,提前预警风险\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时(通过进水水温数据判断),加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n①合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n②适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(SS不超过150mg/L)情况下,也可控制在20~25天。\n3、解决污泥膨胀、老化、腐化、解絮等导致的出水带泥,SS不受控\n强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、腐化、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n4、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n5、短期内无法解决恢复\n及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.75mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.29mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.52℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为401.52mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.24mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.10mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.95mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.09℃。\n进水pH:当前值是17.73。\n进水TDS:当前值为398.87mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水pH异常。\n解决方案:\npH异常导致微生物活性下降,可采用以下方式解决:\n1、启动水质溯源,同步投加药剂调节pH,确保系统各生化段pH在合理范围内;\n2、解决高氨氮硝化反应过多消耗碱度或进水碱度降低导致系统缓冲液体系失衡\n①根据回流混合液硝酸盐浓度和缺氧池碱度核算后,投加工业碱调节pH。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.63mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.13mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.65℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为401.08mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.38mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.55mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.17℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为798.23mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "超出"
- },
- {
- "from": "human",
- "value": "状态:进水TDS超过管控值。\n解决方案:\n以进水TDS数据表征有毒物质,由于有毒物质进入系统导致微生物活性下降,可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争取第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力\n3、毒性小试实验方案\n将现有生化系统活性厌氧段污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下,开启六连搅拌器,缓慢搅拌,搅拌时间模拟厌氧段停留时间,每 2h 取样 1 次,按上述比例24h 换水 1 次(换水量为 50%),连续运行 72h,观察总磷去除效率,根据实验结果确定:① 探究污水对厌氧释磷的毒性抑制作用;② 探究解决当前生化池毒性抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,系统总磷去除率不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,总磷去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.82mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.62mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.55℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为401.23mg/L,管控值为600mg/L。\n出水SS存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "存在"
- },
- {
- "from": "human",
- "value": "状态:基本确认出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.77mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.51mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.25℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为399.54mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验比对,出水SS超标了。\n解决方案:\n1、出水SS指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.85mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.40mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.11℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为400.70mg/L,管控值为600mg/L。\n出水SS不存在连续两个相邻检测数据超标。\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "正常"
- },
- {
- "from": "human",
- "value": "出水SS是否存在连续两次超标?"
- },
- {
- "from": "gpt",
- "value": "不存在"
- },
- {
- "from": "human",
- "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
- },
- {
- "from": "gpt",
- "value": "不超标"
- },
- {
- "from": "human",
- "value": "状态:人工化验不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为0.03mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.04mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.33℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为401.94mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "{{alert}}\n出水SS在线仪表是正常的吗?"
- },
- {
- "from": "gpt",
- "value": "不正常"
- },
- {
- "from": "human",
- "value": "状态:出水SS在线检测仪表不正常。\n解决方案:\n请使用如下排查方式进行:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.06mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.84mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.98mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.43℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为400.97mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.58mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.45mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.73℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为400.44mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.17mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.01mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.79℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为401.08mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "低于设计值"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.33mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为320.29mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.77℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为400.65mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是小于设计值\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.00mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为319.81mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.32℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为399.46mg/L,管控值为600mg/L。\n进水总量与设计值的比较是大于但未超过110%\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.13mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为319.07mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.54℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为398.73mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值但是低于110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS未超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.48mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为465.45mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.65℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为398.60mg/L,管控值为600mg/L。\n进水总量与设计值的比较是小于设计值\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "小于设计值"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.81mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为463.98mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.45mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.36℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为400.60mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是大于但未超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "大于但未超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值但小于等于进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n①污泥浓度控制调整\n增加剩余污泥排放量,降低系统污泥浓度,每次调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。\n②外回流量调整\n适当降低外回流比,避免沉淀池固体负荷过高;A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。③风量调整\n适当降低DO,避免过曝,调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.34mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为462.64mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.44mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.24℃。\n进水pH:当前值是6.95。\n进水TDS:当前值为401.84mg/L,管控值为600mg/L。\n\n进水总量与设计值的比较是超过110%\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水SS高于设计值?"
- },
- {
- "from": "gpt",
- "value": "高于设计值110%"
- },
- {
- "from": "human",
- "value": "进水总量与设计值的比较是?"
- },
- {
- "from": "gpt",
- "value": "超过110%"
- },
- {
- "from": "human",
- "value": "状态:进水SS超设计值110%,进水SS总量超过进水SS总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n①优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n②不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n③一般进水SS超标同步伴随COD等其他指标超标,当系统长时间受到超标冲击,远超系统设计处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n④运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.48mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.82mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.14℃。\n进水pH:当前值是7.00。\n进水TDS:当前值为398.71mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分不高、浮渣也不多"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.32mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.80mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1000mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4000mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.02℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为399.93mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "都未大于"
- },
- {
- "from": "human",
- "value": "{{alert}}\n进水是否无机成分高或浮渣类多?"
- },
- {
- "from": "gpt",
- "value": "无机成分高或浮渣多"
- },
- {
- "from": "human",
- "value": "状态:进水无机成分高或浮渣类多。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.27mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.32mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值2500mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.01mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.68℃。\n进水pH:当前值是7.03。\n进水TDS:当前值为400.44mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有大于"
- },
- {
- "from": "human",
- "value": "状态:MLVSS/MLSS大于各厂稳态值。\n解决方案:\n由于进水无机成分高或浮渣类多,造成出水SS超标,可采用以下方式解决:\n1、开展水质溯源进行源头控制;同步开展混凝药剂小试和投加点位优化验证,强化预处理效能。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.98mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.49mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.02mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.79℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为400.31mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.30mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.01mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为5.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.28℃。\n进水pH:当前值是6.99。\n进水TDS:当前值为400.22mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "各个好氧池的溶解氧当前值是否超出各自对应的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:DO控制过高,曝气过渡。\n解决方案:\nDO控制过高,曝气过渡,污泥存在解絮,出水带泥,使得微生物活性下降,可采用以下方式解决:\n1、解决供风量过高导致的好氧段DO过高\n首先查看风机状态,尝试降低已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,可以通过放空阀进行气量放空。A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决由于生化池液位差异引起生化池气量分配不均导致的混合液回流DO过高\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.62mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.79mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.04mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.51℃。\n进水pH:当前值是7.04。\n进水TDS:当前值为398.11mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "都未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.87mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为265.11mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值5100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.05mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.42mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.88℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为399.47mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "每个池子生化池污泥浓度MLSS是否超出各自的稳态值?"
- },
- {
- "from": "gpt",
- "value": "至少一个池子有超出"
- },
- {
- "from": "human",
- "value": "状态:生化池污泥浓度过高。\n解决方案:\n由于污泥增值过快或排泥不及时等导致系统污泥浓度过高,使得微生物活性下降,可采用以下方式解决:\n1、进行工艺调整\n加大剩余污泥排放量,缩短污泥龄,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.95mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.58mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.99mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.40℃。\n进水pH:当前值是6.96。\n进水TDS:当前值为400.41mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.56mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.35mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.96mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是5.96℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为399.41mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水水温是否小于8℃?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水水温偏低。\n解决方案:\n由于水温低于8℃,微生物活性明显降低,可采用以下方式解决:\n1、强化温降数据收集与分析,提前预警风险\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时(通过进水水温数据判断),加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n①合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n②适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(SS不超过150mg/L)情况下,也可控制在20~25天。\n3、解决污泥膨胀、老化、腐化、解絮等导致的出水带泥,SS不受控\n强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、腐化、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n4、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n5、短期内无法解决恢复\n及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.24mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为263.19mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.43mg/L,稳态值2.2mg/L。\n进水水温:当前值是17.09℃。\n进水pH:当前值是6.98。\n进水TDS:当前值为399.36mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "否"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为18.61mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为262.79mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.03mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.19℃。\n进水pH:当前值是16.36。\n进水TDS:当前值为399.34mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水pH是否小于6或大于9?"
- },
- {
- "from": "gpt",
- "value": "是"
- },
- {
- "from": "human",
- "value": "状态:进水pH异常。\n解决方案:\npH异常导致微生物活性下降,可采用以下方式解决:\n1、启动水质溯源,同步投加药剂调节pH,确保系统各生化段pH在合理范围内;\n2、解决高氨氮硝化反应过多消耗碱度或进水碱度降低导致系统缓冲液体系失衡\n①根据回流混合液硝酸盐浓度和缺氧池碱度核算后,投加工业碱调节pH。"
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.52mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.08mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为0.97mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.40mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.24℃。\n进水pH:当前值是6.97。\n进水TDS:当前值为398.33mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "未超出"
- },
- {
- "from": "human",
- "value": ""
- }
- ]
- },
- {
- "system": "作为一位经验丰富的污水处理厂专家,请根据以下污水处理厂的关键指标数据,回答后续的一系列问题。\n对于每个问题,请给出最符合当前数据的选项作为答案:\n污水处理厂的关键指标数据如下:\n\n\"\"\"\n出水SS:当前值为17.25mg/L,标准值为10 mg/L,管控值为8mg/L。\n进水SS:当前值为264.32mg/L,设计值为315mg/L。\n池1 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池2 MLVSS:当前值1900mg/L,稳态值2000mg/L。\n池1 MLSS:当前值3000mg/L,稳态值4000mg/L。\n池2 MLSS:当前值3100mg/L,稳态值4100mg/L。\n池1好氧池溶解氧:当前值为1.00mg/L,稳态值2mg/L。\n池2好氧池溶解氧:当前值为1.41mg/L,稳态值2.2mg/L。\n进水水温:当前值是18.70℃。\n进水pH:当前值是7.02。\n进水TDS:当前值为800.18mg/L,管控值为600mg/L。\n\n\n\"\"\"\n\n出水SS是否存在连续两次超标?(存在/不存在)。\n进水SS高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的MLVSS与MLSS的比值是否大于其对应MLVSS与MLSS的稳态值比值?(至少一个池子有大于/都未大于)。\n各个好氧池的溶解氧当前值是否超出各自对应的稳态值?(至少一个池子有超出/都未超出)。\n每个池子生化池污泥浓度MLSS是否超出各自的稳态值?(都未超出/至少一个池子有超出)。\n进水水温是否小于8℃?(是/否)。\n进水pH是否小于6或大于9?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。\n\n请基于专业知识和经验,给出你的判断,无需列出判断依据。让我们认真审视数据,给出客观准确的评估。只需给出问题后括号内的选项即可,无需解释。",
- "conversations": [
- {
- "from": "human",
- "value": "进水TDS是否超出管控值?"
- },
- {
- "from": "gpt",
- "value": "超出"
- },
- {
- "from": "human",
- "value": "状态:进水TDS超过管控值。\n解决方案:\n以进水TDS数据表征有毒物质,由于有毒物质进入系统导致微生物活性下降,可采用以下方式解决:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争取第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力\n3、毒性小试实验方案\n将现有生化系统活性厌氧段污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下,开启六连搅拌器,缓慢搅拌,搅拌时间模拟厌氧段停留时间,每 2h 取样 1 次,按上述比例24h 换水 1 次(换水量为 50%),连续运行 72h,观察总磷去除效率,根据实验结果确定:① 探究污水对厌氧释磷的毒性抑制作用;② 探究解决当前生化池毒性抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,系统总磷去除率不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,总磷去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
- }
- ]
- }
- ]
|