出水COD.json 764 KB

12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182838485868788899091929394959697989910010110210310410510610710810911011111211311411511611711811912012112212312412512612712812913013113213313413513613713813914014114214314414514614714814915015115215315415515615715815916016116216316416516616716816917017117217317417517617717817918018118218318418518618718818919019119219319419519619719819920020120220320420520620720820921021121221321421521621721821922022122222322422522622722822923023123223323423523623723823924024124224324424524624724824925025125225325425525625725825926026126226326426526626726826927027127227327427527627727827928028128228328428528628728828929029129229329429529629729829930030130230330430530630730830931031131231331431531631731831932032132232332432532632732832933033133233333433533633733833934034134234334434534634734834935035135235335435535635735835936036136236336436536636736836937037137237337437537637737837938038138238338438538638738838939039139239339439539639739839940040140240340440540640740840941041141241341441541641741841942042142242342442542642742842943043143243343443543643743843944044144244344444544644744844945045145245345445545645745845946046146246346446546646746846947047147247347447547647747847948048148248348448548648748848949049149249349449549649749849950050150250350450550650750850951051151251351451551651751851952052152252352452552652752852953053153253353453553653753853954054154254354454554654754854955055155255355455555655755855956056156256356456556656756856957057157257357457557657757857958058158258358458558658758858959059159259359459559659759859960060160260360460560660760860961061161261361461561661761861962062162262362462562662762862963063163263363463563663763863964064164264364464564664764864965065165265365465565665765865966066166266366466566666766866967067167267367467567667767867968068168268368468568668768868969069169269369469569669769869970070170270370470570670770870971071171271371471571671771871972072172272372472572672772872973073173273373473573673773873974074174274374474574674774874975075175275375475575675775875976076176276376476576676776876977077177277377477577677777877978078178278378478578678778878979079179279379479579679779879980080180280380480580680780880981081181281381481581681781881982082182282382482582682782882983083183283383483583683783883984084184284384484584684784884985085185285385485585685785885986086186286386486586686786886987087187287387487587687787887988088188288388488588688788888989089189289389489589689789889990090190290390490590690790890991091191291391491591691791891992092192292392492592692792892993093193293393493593693793893994094194294394494594694794894995095195295395495595695795895996096196296396496596696796896997097197297397497597697797897998098198298398498598698798898999099199299399499599699799899910001001100210031004100510061007100810091010101110121013101410151016101710181019102010211022102310241025102610271028102910301031103210331034103510361037103810391040104110421043104410451046104710481049105010511052105310541055105610571058105910601061106210631064106510661067106810691070107110721073107410751076107710781079108010811082108310841085108610871088108910901091109210931094109510961097109810991100110111021103110411051106110711081109111011111112111311141115111611171118111911201121112211231124112511261127112811291130113111321133113411351136113711381139114011411142114311441145114611471148114911501151115211531154115511561157115811591160116111621163116411651166116711681169117011711172117311741175117611771178117911801181118211831184118511861187118811891190119111921193119411951196119711981199120012011202120312041205120612071208120912101211121212131214121512161217121812191220122112221223122412251226122712281229123012311232123312341235123612371238123912401241124212431244124512461247124812491250125112521253125412551256125712581259126012611262126312641265126612671268126912701271127212731274127512761277127812791280128112821283128412851286128712881289129012911292129312941295129612971298129913001301130213031304130513061307130813091310131113121313131413151316131713181319132013211322132313241325132613271328132913301331133213331334133513361337133813391340134113421343134413451346134713481349135013511352135313541355135613571358135913601361136213631364136513661367136813691370137113721373137413751376137713781379138013811382138313841385138613871388138913901391139213931394139513961397139813991400140114021403140414051406140714081409141014111412141314141415141614171418141914201421142214231424142514261427142814291430143114321433143414351436143714381439144014411442144314441445144614471448144914501451145214531454145514561457145814591460146114621463146414651466146714681469147014711472147314741475147614771478147914801481148214831484148514861487148814891490149114921493149414951496149714981499150015011502150315041505150615071508150915101511151215131514151515161517151815191520152115221523152415251526152715281529153015311532153315341535153615371538153915401541154215431544154515461547154815491550155115521553155415551556155715581559156015611562156315641565156615671568156915701571157215731574157515761577157815791580158115821583158415851586158715881589159015911592159315941595159615971598159916001601160216031604160516061607160816091610161116121613161416151616161716181619162016211622162316241625162616271628162916301631163216331634163516361637163816391640164116421643164416451646164716481649165016511652165316541655165616571658165916601661166216631664166516661667166816691670167116721673167416751676167716781679168016811682168316841685168616871688168916901691169216931694169516961697169816991700170117021703170417051706170717081709171017111712171317141715171617171718171917201721172217231724172517261727172817291730173117321733173417351736173717381739174017411742174317441745174617471748174917501751175217531754175517561757175817591760176117621763176417651766176717681769177017711772177317741775177617771778177917801781178217831784178517861787178817891790179117921793179417951796179717981799180018011802180318041805180618071808180918101811181218131814181518161817181818191820182118221823182418251826182718281829183018311832183318341835183618371838183918401841184218431844184518461847184818491850185118521853185418551856185718581859186018611862186318641865186618671868186918701871187218731874187518761877187818791880188118821883188418851886188718881889189018911892189318941895189618971898189919001901190219031904190519061907190819091910191119121913191419151916191719181919192019211922192319241925192619271928192919301931193219331934193519361937193819391940194119421943194419451946194719481949195019511952195319541955195619571958195919601961196219631964196519661967196819691970197119721973197419751976197719781979198019811982198319841985198619871988198919901991199219931994199519961997199819992000200120022003200420052006200720082009201020112012201320142015201620172018201920202021202220232024202520262027202820292030203120322033203420352036203720382039204020412042204320442045204620472048204920502051205220532054205520562057205820592060206120622063206420652066206720682069207020712072207320742075207620772078207920802081208220832084208520862087208820892090209120922093209420952096209720982099210021012102210321042105210621072108210921102111211221132114211521162117211821192120212121222123212421252126212721282129213021312132213321342135213621372138213921402141214221432144214521462147214821492150215121522153215421552156215721582159216021612162216321642165216621672168216921702171217221732174217521762177217821792180218121822183218421852186218721882189219021912192219321942195219621972198219922002201220222032204220522062207220822092210221122122213221422152216221722182219222022212222222322242225222622272228222922302231223222332234223522362237223822392240224122422243224422452246224722482249225022512252225322542255225622572258225922602261226222632264226522662267226822692270227122722273227422752276227722782279228022812282228322842285228622872288228922902291229222932294229522962297229822992300230123022303230423052306230723082309231023112312231323142315231623172318231923202321232223232324232523262327232823292330233123322333233423352336233723382339234023412342234323442345234623472348234923502351235223532354235523562357235823592360236123622363236423652366236723682369237023712372237323742375237623772378237923802381238223832384238523862387238823892390239123922393239423952396239723982399240024012402240324042405240624072408240924102411241224132414241524162417241824192420242124222423242424252426242724282429243024312432243324342435243624372438243924402441244224432444244524462447244824492450245124522453245424552456245724582459246024612462246324642465246624672468246924702471247224732474247524762477247824792480248124822483248424852486248724882489249024912492249324942495249624972498249925002501250225032504250525062507250825092510251125122513251425152516251725182519252025212522252325242525252625272528252925302531253225332534253525362537253825392540254125422543254425452546254725482549255025512552255325542555255625572558255925602561256225632564256525662567256825692570257125722573257425752576257725782579258025812582258325842585258625872588258925902591259225932594259525962597259825992600260126022603260426052606260726082609261026112612261326142615261626172618261926202621262226232624262526262627262826292630263126322633263426352636263726382639264026412642264326442645264626472648264926502651265226532654265526562657265826592660266126622663266426652666266726682669267026712672267326742675267626772678267926802681268226832684268526862687268826892690269126922693269426952696269726982699270027012702270327042705270627072708270927102711271227132714271527162717271827192720272127222723272427252726272727282729273027312732273327342735273627372738273927402741274227432744274527462747274827492750275127522753275427552756275727582759276027612762276327642765276627672768276927702771277227732774277527762777277827792780278127822783278427852786278727882789279027912792279327942795279627972798279928002801280228032804280528062807280828092810281128122813281428152816281728182819282028212822282328242825282628272828282928302831283228332834283528362837283828392840284128422843284428452846284728482849285028512852285328542855285628572858285928602861286228632864286528662867286828692870287128722873287428752876287728782879288028812882288328842885288628872888288928902891289228932894289528962897289828992900290129022903290429052906290729082909291029112912291329142915291629172918291929202921292229232924292529262927292829292930293129322933293429352936293729382939294029412942294329442945294629472948294929502951295229532954295529562957295829592960296129622963296429652966296729682969297029712972297329742975297629772978297929802981298229832984298529862987298829892990299129922993299429952996299729982999300030013002300330043005300630073008300930103011301230133014301530163017301830193020302130223023302430253026302730283029303030313032303330343035303630373038303930403041304230433044304530463047304830493050305130523053305430553056305730583059306030613062306330643065306630673068306930703071307230733074307530763077307830793080308130823083308430853086308730883089309030913092309330943095309630973098309931003101310231033104310531063107310831093110311131123113311431153116311731183119312031213122312331243125312631273128312931303131313231333134313531363137313831393140314131423143314431453146314731483149315031513152315331543155315631573158315931603161316231633164316531663167316831693170317131723173317431753176317731783179318031813182318331843185318631873188318931903191319231933194319531963197319831993200320132023203320432053206320732083209321032113212321332143215321632173218321932203221322232233224322532263227322832293230323132323233323432353236323732383239324032413242324332443245324632473248324932503251325232533254325532563257325832593260326132623263326432653266326732683269327032713272327332743275327632773278327932803281328232833284328532863287328832893290329132923293329432953296329732983299330033013302330333043305330633073308330933103311331233133314331533163317331833193320332133223323332433253326332733283329333033313332333333343335333633373338333933403341334233433344334533463347334833493350335133523353335433553356335733583359336033613362336333643365336633673368336933703371337233733374337533763377337833793380338133823383338433853386338733883389339033913392339333943395339633973398339934003401340234033404340534063407340834093410341134123413341434153416341734183419342034213422342334243425342634273428342934303431343234333434343534363437343834393440344134423443344434453446344734483449345034513452345334543455345634573458345934603461346234633464346534663467346834693470347134723473347434753476347734783479348034813482348334843485348634873488348934903491349234933494349534963497349834993500350135023503350435053506350735083509351035113512351335143515351635173518351935203521352235233524352535263527352835293530353135323533353435353536353735383539354035413542354335443545354635473548354935503551355235533554355535563557355835593560356135623563356435653566356735683569357035713572357335743575357635773578357935803581358235833584358535863587358835893590359135923593359435953596359735983599360036013602360336043605360636073608360936103611361236133614361536163617361836193620362136223623362436253626362736283629363036313632363336343635363636373638363936403641364236433644364536463647364836493650365136523653365436553656365736583659366036613662366336643665366636673668366936703671367236733674367536763677367836793680368136823683368436853686368736883689369036913692369336943695369636973698369937003701370237033704370537063707370837093710371137123713371437153716371737183719372037213722372337243725372637273728372937303731373237333734373537363737373837393740374137423743374437453746374737483749375037513752375337543755375637573758375937603761376237633764376537663767376837693770377137723773377437753776377737783779378037813782378337843785378637873788378937903791379237933794379537963797379837993800380138023803380438053806380738083809381038113812381338143815381638173818381938203821382238233824382538263827382838293830383138323833383438353836383738383839384038413842384338443845384638473848384938503851385238533854385538563857385838593860386138623863386438653866386738683869387038713872387338743875387638773878387938803881388238833884388538863887388838893890389138923893389438953896389738983899390039013902390339043905390639073908390939103911391239133914391539163917391839193920392139223923392439253926392739283929393039313932393339343935393639373938393939403941394239433944394539463947394839493950395139523953395439553956395739583959396039613962396339643965396639673968396939703971397239733974397539763977397839793980398139823983398439853986398739883989399039913992399339943995399639973998399940004001400240034004400540064007400840094010401140124013401440154016401740184019402040214022402340244025402640274028402940304031403240334034403540364037403840394040404140424043404440454046404740484049405040514052405340544055405640574058405940604061406240634064406540664067406840694070407140724073407440754076407740784079408040814082408340844085408640874088408940904091409240934094409540964097409840994100410141024103410441054106410741084109411041114112411341144115411641174118411941204121412241234124412541264127412841294130413141324133413441354136413741384139414041414142414341444145414641474148414941504151415241534154415541564157415841594160416141624163416441654166416741684169417041714172417341744175417641774178417941804181418241834184418541864187418841894190419141924193419441954196419741984199420042014202420342044205420642074208420942104211421242134214421542164217421842194220422142224223422442254226422742284229423042314232423342344235423642374238423942404241424242434244424542464247424842494250425142524253425442554256425742584259426042614262426342644265426642674268426942704271427242734274427542764277427842794280428142824283428442854286428742884289429042914292429342944295429642974298429943004301430243034304430543064307430843094310431143124313431443154316431743184319432043214322432343244325432643274328432943304331433243334334433543364337433843394340434143424343434443454346434743484349435043514352435343544355435643574358435943604361436243634364436543664367436843694370437143724373437443754376437743784379438043814382438343844385438643874388438943904391439243934394439543964397439843994400440144024403440444054406440744084409441044114412441344144415441644174418441944204421442244234424442544264427442844294430443144324433443444354436443744384439444044414442444344444445444644474448444944504451445244534454445544564457445844594460446144624463446444654466446744684469447044714472447344744475447644774478447944804481448244834484448544864487448844894490449144924493449444954496449744984499450045014502450345044505450645074508450945104511451245134514451545164517451845194520452145224523452445254526452745284529453045314532453345344535453645374538453945404541454245434544454545464547454845494550455145524553455445554556455745584559456045614562456345644565456645674568456945704571457245734574457545764577457845794580458145824583458445854586458745884589459045914592459345944595459645974598459946004601460246034604460546064607460846094610461146124613461446154616461746184619462046214622462346244625462646274628462946304631463246334634463546364637463846394640464146424643464446454646464746484649465046514652465346544655465646574658465946604661466246634664466546664667466846694670467146724673467446754676467746784679468046814682468346844685468646874688468946904691469246934694469546964697469846994700470147024703470447054706470747084709471047114712471347144715471647174718471947204721472247234724472547264727472847294730473147324733473447354736473747384739474047414742474347444745474647474748474947504751475247534754475547564757475847594760476147624763476447654766476747684769477047714772477347744775477647774778477947804781478247834784478547864787478847894790479147924793479447954796479747984799480048014802480348044805480648074808480948104811481248134814481548164817481848194820482148224823482448254826482748284829483048314832483348344835483648374838483948404841484248434844484548464847484848494850485148524853485448554856485748584859486048614862486348644865486648674868486948704871487248734874487548764877487848794880488148824883488448854886488748884889489048914892489348944895489648974898489949004901490249034904490549064907490849094910491149124913491449154916491749184919492049214922492349244925492649274928492949304931493249334934493549364937493849394940494149424943494449454946494749484949495049514952495349544955495649574958495949604961496249634964496549664967496849694970497149724973497449754976497749784979498049814982498349844985498649874988498949904991499249934994499549964997499849995000500150025003500450055006500750085009501050115012501350145015501650175018501950205021502250235024502550265027502850295030503150325033503450355036503750385039504050415042504350445045504650475048504950505051505250535054505550565057505850595060506150625063506450655066506750685069507050715072507350745075507650775078507950805081508250835084508550865087508850895090509150925093509450955096509750985099510051015102510351045105510651075108510951105111511251135114511551165117511851195120512151225123512451255126512751285129513051315132513351345135513651375138513951405141514251435144514551465147514851495150515151525153515451555156515751585159516051615162516351645165516651675168516951705171517251735174517551765177517851795180518151825183518451855186518751885189519051915192519351945195519651975198519952005201520252035204520552065207520852095210521152125213521452155216521752185219522052215222522352245225522652275228522952305231523252335234523552365237523852395240524152425243524452455246524752485249525052515252525352545255525652575258525952605261526252635264526552665267526852695270527152725273527452755276527752785279528052815282528352845285528652875288528952905291529252935294529552965297529852995300530153025303530453055306530753085309531053115312531353145315531653175318531953205321532253235324532553265327532853295330533153325333533453355336533753385339534053415342534353445345534653475348534953505351535253535354535553565357535853595360536153625363536453655366536753685369537053715372537353745375537653775378537953805381538253835384538553865387538853895390539153925393539453955396539753985399540054015402540354045405540654075408540954105411541254135414541554165417541854195420542154225423542454255426542754285429543054315432543354345435543654375438543954405441544254435444544554465447544854495450545154525453545454555456545754585459546054615462546354645465546654675468546954705471547254735474547554765477547854795480548154825483548454855486548754885489549054915492549354945495549654975498549955005501550255035504550555065507550855095510551155125513551455155516551755185519552055215522552355245525552655275528552955305531553255335534553555365537553855395540554155425543554455455546554755485549555055515552555355545555555655575558555955605561556255635564556555665567556855695570557155725573557455755576557755785579558055815582558355845585558655875588558955905591559255935594559555965597559855995600560156025603560456055606560756085609561056115612561356145615561656175618561956205621562256235624562556265627562856295630563156325633563456355636563756385639564056415642564356445645564656475648564956505651565256535654565556565657565856595660566156625663566456655666566756685669567056715672567356745675567656775678567956805681568256835684568556865687568856895690569156925693569456955696569756985699570057015702570357045705570657075708570957105711571257135714571557165717571857195720572157225723572457255726572757285729573057315732573357345735573657375738573957405741574257435744574557465747574857495750575157525753575457555756575757585759576057615762576357645765576657675768576957705771577257735774577557765777577857795780578157825783578457855786578757885789579057915792579357945795579657975798579958005801580258035804580558065807580858095810581158125813581458155816581758185819582058215822582358245825582658275828582958305831583258335834583558365837583858395840584158425843584458455846584758485849585058515852585358545855585658575858585958605861586258635864586558665867586858695870587158725873587458755876587758785879588058815882588358845885588658875888588958905891589258935894589558965897589858995900590159025903590459055906590759085909591059115912591359145915591659175918591959205921592259235924592559265927592859295930593159325933593459355936593759385939594059415942594359445945594659475948594959505951595259535954595559565957595859595960596159625963596459655966596759685969597059715972597359745975597659775978597959805981598259835984598559865987598859895990599159925993599459955996599759985999600060016002600360046005600660076008600960106011601260136014601560166017601860196020602160226023602460256026
  1. [
  2. {
  3. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n\n出水COD:当前值为36.30mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.43mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为502.33mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.50%,管控值为80%。\n池2污泥沉降比:当前值为60.57%,管控值为80%。\n池1污泥体积指数:当前值为135.77mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.45mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4. "conversations": [
  5. {
  6. "from": "human",
  7. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  8. },
  9. {
  10. "from": "gpt",
  11. "value": "正常"
  12. },
  13. {
  14. "from": "human",
  15. "value": "出水COD是否连续两次超标?"
  16. },
  17. {
  18. "from": "gpt",
  19. "value": "存在"
  20. },
  21. {
  22. "from": "human",
  23. "value": "状态:基本确认出水COD超标了\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  24. }
  25. ]
  26. },
  27. {
  28. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.99mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.62mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为502.68mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.23%,管控值为80%。\n池2污泥沉降比:当前值为60.67%,管控值为80%。\n池1污泥体积指数:当前值为133.54mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.27mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  29. "conversations": [
  30. {
  31. "from": "human",
  32. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  33. },
  34. {
  35. "from": "gpt",
  36. "value": "正常"
  37. },
  38. {
  39. "from": "human",
  40. "value": "出水COD是否连续两次超标?"
  41. },
  42. {
  43. "from": "gpt",
  44. "value": "不存在"
  45. },
  46. {
  47. "from": "human",
  48. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  49. },
  50. {
  51. "from": "gpt",
  52. "value": "超标"
  53. },
  54. {
  55. "from": "human",
  56. "value": "状态:人工化验比对,出水COD超标了。\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  57. }
  58. ]
  59. },
  60. {
  61. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.38mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.53mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为500.84mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.33%,管控值为80%。\n池2污泥沉降比:当前值为59.82%,管控值为80%。\n池1污泥体积指数:当前值为135.74mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.76mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  62. "conversations": [
  63. {
  64. "from": "human",
  65. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  66. },
  67. {
  68. "from": "gpt",
  69. "value": "正常"
  70. },
  71. {
  72. "from": "human",
  73. "value": "出水COD是否连续两次超标?"
  74. },
  75. {
  76. "from": "gpt",
  77. "value": "不存在"
  78. },
  79. {
  80. "from": "human",
  81. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  82. },
  83. {
  84. "from": "gpt",
  85. "value": "不超标"
  86. },
  87. {
  88. "from": "human",
  89. "value": "状态:人工化验出水COD不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
  90. }
  91. ]
  92. },
  93. {
  94. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为-0.03mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.19mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为502.81mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.49%,管控值为80%。\n池2污泥沉降比:当前值为59.73%,管控值为80%。\n池1污泥体积指数:当前值为134.65mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.11mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  95. "conversations": [
  96. {
  97. "from": "human",
  98. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  99. },
  100. {
  101. "from": "gpt",
  102. "value": "不正常"
  103. },
  104. {
  105. "from": "human",
  106. "value": "状态:仪表不正常\n解决方案:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
  107. }
  108. ]
  109. },
  110. {
  111. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.36mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.62mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为501.48mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.53%,管控值为80%。\n池2污泥沉降比:当前值为60.90%,管控值为80%。\n池1污泥体积指数:当前值为135.26mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.11mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  112. "conversations": [
  113. {
  114. "from": "human",
  115. "value": "进水COD高于设计值?"
  116. },
  117. {
  118. "from": "gpt",
  119. "value": "低于设计值"
  120. },
  121. {
  122. "from": "human",
  123. "value": "进水总量与设计值的比较是?"
  124. },
  125. {
  126. "from": "gpt",
  127. "value": "小于设计值"
  128. },
  129. {
  130. "from": "human",
  131. "value": ""
  132. }
  133. ]
  134. },
  135. {
  136. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.76mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.73mg/L,设计值为630mg/L。\n进水水温:当前值是11.50℃。\n进水TDS:当前值为501.55mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.06%,管控值为80%。\n池2污泥沉降比:当前值为60.82%,管控值为80%。\n池1污泥体积指数:当前值为133.28mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.59mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  137. "conversations": [
  138. {
  139. "from": "human",
  140. "value": "进水COD高于设计值?"
  141. },
  142. {
  143. "from": "gpt",
  144. "value": "低于设计值"
  145. },
  146. {
  147. "from": "human",
  148. "value": "进水总量与设计值的比较是?"
  149. },
  150. {
  151. "from": "gpt",
  152. "value": "大于但未超过110%"
  153. },
  154. {
  155. "from": "human",
  156. "value": "状态:进水COD未超设计值,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  157. }
  158. ]
  159. },
  160. {
  161. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.79mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.98mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为503.70mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.07%,管控值为80%。\n池2污泥沉降比:当前值为59.49%,管控值为80%。\n池1污泥体积指数:当前值为136.14mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.74mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  162. "conversations": [
  163. {
  164. "from": "human",
  165. "value": "进水COD高于设计值?"
  166. },
  167. {
  168. "from": "gpt",
  169. "value": "低于设计值"
  170. },
  171. {
  172. "from": "human",
  173. "value": "进水总量与设计值的比较是?"
  174. },
  175. {
  176. "from": "gpt",
  177. "value": "超过110%"
  178. },
  179. {
  180. "from": "human",
  181. "value": "状态:进水COD未超设计值,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  182. }
  183. ]
  184. },
  185. {
  186. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.96mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为649.25mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为503.44mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.40%,管控值为80%。\n池2污泥沉降比:当前值为60.77%,管控值为80%。\n池1污泥体积指数:当前值为135.50mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.93mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  187. "conversations": [
  188. {
  189. "from": "human",
  190. "value": "进水COD高于设计值?"
  191. },
  192. {
  193. "from": "gpt",
  194. "value": "高于设计值但是低于110%"
  195. },
  196. {
  197. "from": "human",
  198. "value": "进水总量与设计值的比较是?"
  199. },
  200. {
  201. "from": "gpt",
  202. "value": "小于设计值"
  203. },
  204. {
  205. "from": "human",
  206. "value": ""
  207. }
  208. ]
  209. },
  210. {
  211. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.10mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为650.94mg/L,设计值为630mg/L。\n进水水温:当前值是11.53℃。\n进水TDS:当前值为502.08mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.41%,管控值为80%。\n池2污泥沉降比:当前值为59.14%,管控值为80%。\n池1污泥体积指数:当前值为136.88mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.11mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  212. "conversations": [
  213. {
  214. "from": "human",
  215. "value": "进水COD高于设计值?"
  216. },
  217. {
  218. "from": "gpt",
  219. "value": "高于设计值但是低于110%"
  220. },
  221. {
  222. "from": "human",
  223. "value": "进水总量与设计值的比较是?"
  224. },
  225. {
  226. "from": "gpt",
  227. "value": "大于但未超过110%"
  228. },
  229. {
  230. "from": "human",
  231. "value": "状态:进水COD未超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  232. }
  233. ]
  234. },
  235. {
  236. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.63mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为651.46mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为503.28mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.52%,管控值为80%。\n池2污泥沉降比:当前值为59.31%,管控值为80%。\n池1污泥体积指数:当前值为133.54mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.56mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  237. "conversations": [
  238. {
  239. "from": "human",
  240. "value": "进水COD高于设计值?"
  241. },
  242. {
  243. "from": "gpt",
  244. "value": "高于设计值但是低于110%"
  245. },
  246. {
  247. "from": "human",
  248. "value": "进水总量与设计值的比较是?"
  249. },
  250. {
  251. "from": "gpt",
  252. "value": "超过110%"
  253. },
  254. {
  255. "from": "human",
  256. "value": "状态:进水COD未超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  257. }
  258. ]
  259. },
  260. {
  261. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.68mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.58mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为503.21mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.10%,管控值为80%。\n池2污泥沉降比:当前值为59.32%,管控值为80%。\n池1污泥体积指数:当前值为136.10mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.10mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  262. "conversations": [
  263. {
  264. "from": "human",
  265. "value": "进水COD高于设计值?"
  266. },
  267. {
  268. "from": "gpt",
  269. "value": "高于设计值110%"
  270. },
  271. {
  272. "from": "human",
  273. "value": "进水总量与设计值的比较是?"
  274. },
  275. {
  276. "from": "gpt",
  277. "value": "小于设计值"
  278. },
  279. {
  280. "from": "human",
  281. "value": ""
  282. }
  283. ]
  284. },
  285. {
  286. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.46mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.33mg/L,设计值为630mg/L。\n进水水温:当前值是11.54℃。\n进水TDS:当前值为501.50mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.80%,管控值为80%。\n池2污泥沉降比:当前值为60.27%,管控值为80%。\n池1污泥体积指数:当前值为133.56mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.67mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  287. "conversations": [
  288. {
  289. "from": "human",
  290. "value": "进水COD高于设计值?"
  291. },
  292. {
  293. "from": "gpt",
  294. "value": "高于设计值110%"
  295. },
  296. {
  297. "from": "human",
  298. "value": "进水总量与设计值的比较是?"
  299. },
  300. {
  301. "from": "gpt",
  302. "value": "大于但未超过110%"
  303. },
  304. {
  305. "from": "human",
  306. "value": "状态:进水COD超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  307. }
  308. ]
  309. },
  310. {
  311. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.83mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.34mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为500.90mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.55%,管控值为80%。\n池2污泥沉降比:当前值为60.67%,管控值为80%。\n池1污泥体积指数:当前值为136.80mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.15mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  312. "conversations": [
  313. {
  314. "from": "human",
  315. "value": "进水COD高于设计值?"
  316. },
  317. {
  318. "from": "gpt",
  319. "value": "高于设计值110%"
  320. },
  321. {
  322. "from": "human",
  323. "value": "进水总量与设计值的比较是?"
  324. },
  325. {
  326. "from": "gpt",
  327. "value": "超过110%"
  328. },
  329. {
  330. "from": "human",
  331. "value": "状态:进水COD超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  332. }
  333. ]
  334. },
  335. {
  336. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.83mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.39mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为501.67mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.00%,管控值为80%。\n池2污泥沉降比:当前值为60.52%,管控值为80%。\n池1污泥体积指数:当前值为136.83mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.54mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为3.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  337. "conversations": [
  338. {
  339. "from": "human",
  340. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  341. },
  342. {
  343. "from": "gpt",
  344. "value": "都未低于"
  345. },
  346. {
  347. "from": "human",
  348. "value": ""
  349. }
  350. ]
  351. },
  352. {
  353. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.64mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.85mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为502.29mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.79%,管控值为80%。\n池2污泥沉降比:当前值为59.98%,管控值为80%。\n池1污泥体积指数:当前值为133.98mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.55mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  354. "conversations": [
  355. {
  356. "from": "human",
  357. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  358. },
  359. {
  360. "from": "gpt",
  361. "value": "至少一个池子有低于"
  362. },
  363. {
  364. "from": "human",
  365. "value": "状态:好氧池溶解氧偏低\n解决方案:\n1、解决供风量不足导致的生化池DO过低\n首先查看风机状态,尝试提高已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,启动或切换备用风机,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决曝气管路不畅、漏气等导致的生化池DO过低\n(1)定期及时排出曝气管路中的领凝水保障管路通常。(2)水面上漏点直接维修;水面下漏点,具备停进水条件的放空后维修,不具备的则按环保要求完成备案同意后,争取最短时间内恢复,在此期间根据实际情况灵活采取过渡措施予以保障。\n3、供风量充足,解决曝气器破损或脱落等导致的生化池DO过低\n关闭或调小泄漏处阀门,减小气量损失,保障生化池充氧效果。具备停水放空条件,及时维修或更换。在此期间根据实际情况灵活采取过渡措施予以保障。\n4、供风量充足,解决生化池负或液位差异导致生化池气量分配不均导致的DO过低\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
  366. }
  367. ]
  368. },
  369. {
  370. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.94mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.87mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为501.28mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.28%,管控值为80%。\n池2污泥沉降比:当前值为60.38%,管控值为80%。\n池1污泥体积指数:当前值为133.73mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.05mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  371. "conversations": [
  372. {
  373. "from": "human",
  374. "value": "进水水温是否小于8℃"
  375. },
  376. {
  377. "from": "gpt",
  378. "value": "否"
  379. },
  380. {
  381. "from": "human",
  382. "value": ""
  383. }
  384. ]
  385. },
  386. {
  387. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.81mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.90mg/L,设计值为630mg/L。\n\n进水水温:当前值是3.50℃。\n进水TDS:当前值为502.02mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.48%,管控值为80%。\n池2污泥沉降比:当前值为59.54%,管控值为80%。\n池1污泥体积指数:当前值为135.22mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.42mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  388. "conversations": [
  389. {
  390. "from": "human",
  391. "value": "进水水温是否小于8℃"
  392. },
  393. {
  394. "from": "gpt",
  395. "value": "是"
  396. },
  397. {
  398. "from": "human",
  399. "value": "状态:进水水温小于8℃\n由于水温低于10℃,聚磷菌在低温时生长速度会减慢,生物除磷速率将会迅速下降,微生物活性下降。\n解决方案:\n1、强化温降数据收集与分析,提前预警管控\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时,加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n(1)适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(COD不超过150mg/L)情况下,也可控制在20~25天。\n(2)合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n(3)及时调控回流比,温降或换季期间,较常规运行阶段要适当提高外回流比,一般不超过150%。内回流比则根据总氮变化灵活调整,内外总回流比不宜超过400%。"
  400. }
  401. ]
  402. },
  403. {
  404. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.48mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.90mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为502.61mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.27%,管控值为80%。\n池2污泥沉降比:当前值为59.31%,管控值为80%。\n池1污泥体积指数:当前值为136.46mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.23mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  405. "conversations": [
  406. {
  407. "from": "human",
  408. "value": "进水TDS是否超出管控值?"
  409. },
  410. {
  411. "from": "gpt",
  412. "value": "未超出"
  413. },
  414. {
  415. "from": "human",
  416. "value": ""
  417. }
  418. ]
  419. },
  420. {
  421. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.18mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.57mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为652.86mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.20%,管控值为80%。\n池2污泥沉降比:当前值为60.44%,管控值为80%。\n池1污泥体积指数:当前值为135.79mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.83mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  422. "conversations": [
  423. {
  424. "from": "human",
  425. "value": "进水TDS是否超出管控值?"
  426. },
  427. {
  428. "from": "gpt",
  429. "value": "超出"
  430. },
  431. {
  432. "from": "human",
  433. "value": "状态:进水TDS超过管控值\n解决方案:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争在第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力。\n3、毒性小试实验方案\n将现有生化系统活性污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下开展闷曝小试实验,每 8h 取样 1 次,24h 换水 1 次(换水量为 50%),连续运行 72h,比较不同进水 COD、NH3-N 污染物去除效率,根据实验结果确定:① 探究污水厂进水是否对活性良好的微生物菌群产生延时毒性抑制作用;② 探究生化系统内活性污泥的硝化效能;③探究解决当前生化池硝化抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,化系统COD去除率50%以上且不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,COD去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  434. }
  435. ]
  436. },
  437. {
  438. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.94mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.17mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为501.98mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.09%,管控值为80%。\n池2污泥沉降比:当前值为60.31%,管控值为80%。\n池1污泥体积指数:当前值为135.69mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.05mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  439. "conversations": [
  440. {
  441. "from": "human",
  442. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  443. },
  444. {
  445. "from": "gpt",
  446. "value": "都未超过"
  447. },
  448. {
  449. "from": "human",
  450. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  451. },
  452. {
  453. "from": "gpt",
  454. "value": "否"
  455. },
  456. {
  457. "from": "human",
  458. "value": ""
  459. }
  460. ]
  461. },
  462. {
  463. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.56mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.56mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为503.63mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.13%,管控值为80%。\n池2污泥沉降比:当前值为59.76%,管控值为80%。\n池1污泥体积指数:当前值为133.78mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.24mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  464. "conversations": [
  465. {
  466. "from": "human",
  467. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  468. },
  469. {
  470. "from": "gpt",
  471. "value": "都未超过"
  472. },
  473. {
  474. "from": "human",
  475. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  476. },
  477. {
  478. "from": "gpt",
  479. "value": "是"
  480. },
  481. {
  482. "from": "human",
  483. "value": "状态:生化池有大量泡沫、浮泥等不正常现象\n由于生化池出现大量泡沫、浮泥等不正常现象,可能是污泥膨胀、老化、解絮等导致微生物活性下降,导致出水带泥。\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  484. }
  485. ]
  486. },
  487. {
  488. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.67mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.13mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为501.44mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.07%,管控值为80%。\n池2污泥沉降比:当前值为91.00%,管控值为80%。\n池1污泥体积指数:当前值为133.13mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.39mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  489. "conversations": [
  490. {
  491. "from": "human",
  492. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  493. },
  494. {
  495. "from": "gpt",
  496. "value": "至少一个池子有超过"
  497. },
  498. {
  499. "from": "human",
  500. "value": "状态:污泥沉降比或污泥体积指数异常\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  501. }
  502. ]
  503. },
  504. {
  505. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n\n出水COD:当前值为36.90mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.67mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为503.42mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.41%,管控值为80%。\n池2污泥沉降比:当前值为60.94%,管控值为80%。\n池1污泥体积指数:当前值为135.00mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.30mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  506. "conversations": [
  507. {
  508. "from": "human",
  509. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  510. },
  511. {
  512. "from": "gpt",
  513. "value": "正常"
  514. },
  515. {
  516. "from": "human",
  517. "value": "出水COD是否连续两次超标?"
  518. },
  519. {
  520. "from": "gpt",
  521. "value": "存在"
  522. },
  523. {
  524. "from": "human",
  525. "value": "状态:基本确认出水COD超标了\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  526. }
  527. ]
  528. },
  529. {
  530. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.08mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.57mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为500.83mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.11%,管控值为80%。\n池2污泥沉降比:当前值为60.97%,管控值为80%。\n池1污泥体积指数:当前值为134.82mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.51mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  531. "conversations": [
  532. {
  533. "from": "human",
  534. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  535. },
  536. {
  537. "from": "gpt",
  538. "value": "正常"
  539. },
  540. {
  541. "from": "human",
  542. "value": "出水COD是否连续两次超标?"
  543. },
  544. {
  545. "from": "gpt",
  546. "value": "不存在"
  547. },
  548. {
  549. "from": "human",
  550. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  551. },
  552. {
  553. "from": "gpt",
  554. "value": "超标"
  555. },
  556. {
  557. "from": "human",
  558. "value": "状态:人工化验比对,出水COD超标了。\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  559. }
  560. ]
  561. },
  562. {
  563. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.18mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.39mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为502.12mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.89%,管控值为80%。\n池2污泥沉降比:当前值为59.13%,管控值为80%。\n池1污泥体积指数:当前值为133.54mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.20mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  564. "conversations": [
  565. {
  566. "from": "human",
  567. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  568. },
  569. {
  570. "from": "gpt",
  571. "value": "正常"
  572. },
  573. {
  574. "from": "human",
  575. "value": "出水COD是否连续两次超标?"
  576. },
  577. {
  578. "from": "gpt",
  579. "value": "不存在"
  580. },
  581. {
  582. "from": "human",
  583. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  584. },
  585. {
  586. "from": "gpt",
  587. "value": "不超标"
  588. },
  589. {
  590. "from": "human",
  591. "value": "状态:人工化验出水COD不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
  592. }
  593. ]
  594. },
  595. {
  596. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为-0.02mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.85mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为501.47mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.17%,管控值为80%。\n池2污泥沉降比:当前值为59.89%,管控值为80%。\n池1污泥体积指数:当前值为133.72mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.57mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  597. "conversations": [
  598. {
  599. "from": "human",
  600. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  601. },
  602. {
  603. "from": "gpt",
  604. "value": "不正常"
  605. },
  606. {
  607. "from": "human",
  608. "value": "状态:仪表不正常\n解决方案:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
  609. }
  610. ]
  611. },
  612. {
  613. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.35mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.75mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为503.86mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.25%,管控值为80%。\n池2污泥沉降比:当前值为60.34%,管控值为80%。\n池1污泥体积指数:当前值为133.22mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.12mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  614. "conversations": [
  615. {
  616. "from": "human",
  617. "value": "进水COD高于设计值?"
  618. },
  619. {
  620. "from": "gpt",
  621. "value": "低于设计值"
  622. },
  623. {
  624. "from": "human",
  625. "value": "进水总量与设计值的比较是?"
  626. },
  627. {
  628. "from": "gpt",
  629. "value": "小于设计值"
  630. },
  631. {
  632. "from": "human",
  633. "value": ""
  634. }
  635. ]
  636. },
  637. {
  638. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.15mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.24mg/L,设计值为630mg/L。\n进水水温:当前值是11.53℃。\n进水TDS:当前值为503.38mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.40%,管控值为80%。\n池2污泥沉降比:当前值为60.76%,管控值为80%。\n池1污泥体积指数:当前值为133.55mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.32mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  639. "conversations": [
  640. {
  641. "from": "human",
  642. "value": "进水COD高于设计值?"
  643. },
  644. {
  645. "from": "gpt",
  646. "value": "低于设计值"
  647. },
  648. {
  649. "from": "human",
  650. "value": "进水总量与设计值的比较是?"
  651. },
  652. {
  653. "from": "gpt",
  654. "value": "大于但未超过110%"
  655. },
  656. {
  657. "from": "human",
  658. "value": "状态:进水COD未超设计值,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  659. }
  660. ]
  661. },
  662. {
  663. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.19mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.34mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为503.67mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.91%,管控值为80%。\n池2污泥沉降比:当前值为59.35%,管控值为80%。\n池1污泥体积指数:当前值为135.16mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.15mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  664. "conversations": [
  665. {
  666. "from": "human",
  667. "value": "进水COD高于设计值?"
  668. },
  669. {
  670. "from": "gpt",
  671. "value": "低于设计值"
  672. },
  673. {
  674. "from": "human",
  675. "value": "进水总量与设计值的比较是?"
  676. },
  677. {
  678. "from": "gpt",
  679. "value": "超过110%"
  680. },
  681. {
  682. "from": "human",
  683. "value": "状态:进水COD未超设计值,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  684. }
  685. ]
  686. },
  687. {
  688. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.97mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为651.01mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为501.65mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.22%,管控值为80%。\n池2污泥沉降比:当前值为60.33%,管控值为80%。\n池1污泥体积指数:当前值为133.72mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.08mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  689. "conversations": [
  690. {
  691. "from": "human",
  692. "value": "进水COD高于设计值?"
  693. },
  694. {
  695. "from": "gpt",
  696. "value": "高于设计值但是低于110%"
  697. },
  698. {
  699. "from": "human",
  700. "value": "进水总量与设计值的比较是?"
  701. },
  702. {
  703. "from": "gpt",
  704. "value": "小于设计值"
  705. },
  706. {
  707. "from": "human",
  708. "value": ""
  709. }
  710. ]
  711. },
  712. {
  713. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.20mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为650.62mg/L,设计值为630mg/L。\n进水水温:当前值是11.52℃。\n进水TDS:当前值为501.89mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.98%,管控值为80%。\n池2污泥沉降比:当前值为59.69%,管控值为80%。\n池1污泥体积指数:当前值为134.29mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.99mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  714. "conversations": [
  715. {
  716. "from": "human",
  717. "value": "进水COD高于设计值?"
  718. },
  719. {
  720. "from": "gpt",
  721. "value": "高于设计值但是低于110%"
  722. },
  723. {
  724. "from": "human",
  725. "value": "进水总量与设计值的比较是?"
  726. },
  727. {
  728. "from": "gpt",
  729. "value": "大于但未超过110%"
  730. },
  731. {
  732. "from": "human",
  733. "value": "状态:进水COD未超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  734. }
  735. ]
  736. },
  737. {
  738. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.91mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为648.08mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为500.68mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.68%,管控值为80%。\n池2污泥沉降比:当前值为59.41%,管控值为80%。\n池1污泥体积指数:当前值为133.22mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.86mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  739. "conversations": [
  740. {
  741. "from": "human",
  742. "value": "进水COD高于设计值?"
  743. },
  744. {
  745. "from": "gpt",
  746. "value": "高于设计值但是低于110%"
  747. },
  748. {
  749. "from": "human",
  750. "value": "进水总量与设计值的比较是?"
  751. },
  752. {
  753. "from": "gpt",
  754. "value": "超过110%"
  755. },
  756. {
  757. "from": "human",
  758. "value": "状态:进水COD未超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  759. }
  760. ]
  761. },
  762. {
  763. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.00mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.43mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为500.66mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.48%,管控值为80%。\n池2污泥沉降比:当前值为59.76%,管控值为80%。\n池1污泥体积指数:当前值为134.80mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.83mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  764. "conversations": [
  765. {
  766. "from": "human",
  767. "value": "进水COD高于设计值?"
  768. },
  769. {
  770. "from": "gpt",
  771. "value": "高于设计值110%"
  772. },
  773. {
  774. "from": "human",
  775. "value": "进水总量与设计值的比较是?"
  776. },
  777. {
  778. "from": "gpt",
  779. "value": "小于设计值"
  780. },
  781. {
  782. "from": "human",
  783. "value": ""
  784. }
  785. ]
  786. },
  787. {
  788. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.93mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.99mg/L,设计值为630mg/L。\n进水水温:当前值是11.53℃。\n进水TDS:当前值为500.59mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.38%,管控值为80%。\n池2污泥沉降比:当前值为60.17%,管控值为80%。\n池1污泥体积指数:当前值为135.21mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.68mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  789. "conversations": [
  790. {
  791. "from": "human",
  792. "value": "进水COD高于设计值?"
  793. },
  794. {
  795. "from": "gpt",
  796. "value": "高于设计值110%"
  797. },
  798. {
  799. "from": "human",
  800. "value": "进水总量与设计值的比较是?"
  801. },
  802. {
  803. "from": "gpt",
  804. "value": "大于但未超过110%"
  805. },
  806. {
  807. "from": "human",
  808. "value": "状态:进水COD超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  809. }
  810. ]
  811. },
  812. {
  813. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.31mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.55mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为501.04mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.88%,管控值为80%。\n池2污泥沉降比:当前值为60.98%,管控值为80%。\n池1污泥体积指数:当前值为135.00mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.81mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  814. "conversations": [
  815. {
  816. "from": "human",
  817. "value": "进水COD高于设计值?"
  818. },
  819. {
  820. "from": "gpt",
  821. "value": "高于设计值110%"
  822. },
  823. {
  824. "from": "human",
  825. "value": "进水总量与设计值的比较是?"
  826. },
  827. {
  828. "from": "gpt",
  829. "value": "超过110%"
  830. },
  831. {
  832. "from": "human",
  833. "value": "状态:进水COD超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  834. }
  835. ]
  836. },
  837. {
  838. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.88mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.42mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为503.64mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.15%,管控值为80%。\n池2污泥沉降比:当前值为60.67%,管控值为80%。\n池1污泥体积指数:当前值为135.29mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.91mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为3.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  839. "conversations": [
  840. {
  841. "from": "human",
  842. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  843. },
  844. {
  845. "from": "gpt",
  846. "value": "都未低于"
  847. },
  848. {
  849. "from": "human",
  850. "value": ""
  851. }
  852. ]
  853. },
  854. {
  855. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.30mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.77mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为500.67mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.85%,管控值为80%。\n池2污泥沉降比:当前值为60.71%,管控值为80%。\n池1污泥体积指数:当前值为136.11mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.98mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  856. "conversations": [
  857. {
  858. "from": "human",
  859. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  860. },
  861. {
  862. "from": "gpt",
  863. "value": "至少一个池子有低于"
  864. },
  865. {
  866. "from": "human",
  867. "value": "状态:好氧池溶解氧偏低\n解决方案:\n1、解决供风量不足导致的生化池DO过低\n首先查看风机状态,尝试提高已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,启动或切换备用风机,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决曝气管路不畅、漏气等导致的生化池DO过低\n(1)定期及时排出曝气管路中的领凝水保障管路通常。(2)水面上漏点直接维修;水面下漏点,具备停进水条件的放空后维修,不具备的则按环保要求完成备案同意后,争取最短时间内恢复,在此期间根据实际情况灵活采取过渡措施予以保障。\n3、供风量充足,解决曝气器破损或脱落等导致的生化池DO过低\n关闭或调小泄漏处阀门,减小气量损失,保障生化池充氧效果。具备停水放空条件,及时维修或更换。在此期间根据实际情况灵活采取过渡措施予以保障。\n4、供风量充足,解决生化池负或液位差异导致生化池气量分配不均导致的DO过低\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
  868. }
  869. ]
  870. },
  871. {
  872. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.75mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.92mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为502.61mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.17%,管控值为80%。\n池2污泥沉降比:当前值为59.58%,管控值为80%。\n池1污泥体积指数:当前值为136.55mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.57mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  873. "conversations": [
  874. {
  875. "from": "human",
  876. "value": "进水水温是否小于8℃"
  877. },
  878. {
  879. "from": "gpt",
  880. "value": "否"
  881. },
  882. {
  883. "from": "human",
  884. "value": ""
  885. }
  886. ]
  887. },
  888. {
  889. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.49mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.71mg/L,设计值为630mg/L。\n\n进水水温:当前值是3.54℃。\n进水TDS:当前值为501.58mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.87%,管控值为80%。\n池2污泥沉降比:当前值为59.48%,管控值为80%。\n池1污泥体积指数:当前值为136.15mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.15mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  890. "conversations": [
  891. {
  892. "from": "human",
  893. "value": "进水水温是否小于8℃"
  894. },
  895. {
  896. "from": "gpt",
  897. "value": "是"
  898. },
  899. {
  900. "from": "human",
  901. "value": "状态:进水水温小于8℃\n由于水温低于10℃,聚磷菌在低温时生长速度会减慢,生物除磷速率将会迅速下降,微生物活性下降。\n解决方案:\n1、强化温降数据收集与分析,提前预警管控\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时,加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n(1)适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(COD不超过150mg/L)情况下,也可控制在20~25天。\n(2)合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n(3)及时调控回流比,温降或换季期间,较常规运行阶段要适当提高外回流比,一般不超过150%。内回流比则根据总氮变化灵活调整,内外总回流比不宜超过400%。"
  902. }
  903. ]
  904. },
  905. {
  906. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.23mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.42mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为500.24mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.49%,管控值为80%。\n池2污泥沉降比:当前值为59.99%,管控值为80%。\n池1污泥体积指数:当前值为135.02mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.36mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  907. "conversations": [
  908. {
  909. "from": "human",
  910. "value": "进水TDS是否超出管控值?"
  911. },
  912. {
  913. "from": "gpt",
  914. "value": "未超出"
  915. },
  916. {
  917. "from": "human",
  918. "value": ""
  919. }
  920. ]
  921. },
  922. {
  923. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.94mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.63mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为652.01mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.71%,管控值为80%。\n池2污泥沉降比:当前值为60.00%,管控值为80%。\n池1污泥体积指数:当前值为136.61mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.89mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  924. "conversations": [
  925. {
  926. "from": "human",
  927. "value": "进水TDS是否超出管控值?"
  928. },
  929. {
  930. "from": "gpt",
  931. "value": "超出"
  932. },
  933. {
  934. "from": "human",
  935. "value": "状态:进水TDS超过管控值\n解决方案:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争在第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力。\n3、毒性小试实验方案\n将现有生化系统活性污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下开展闷曝小试实验,每 8h 取样 1 次,24h 换水 1 次(换水量为 50%),连续运行 72h,比较不同进水 COD、NH3-N 污染物去除效率,根据实验结果确定:① 探究污水厂进水是否对活性良好的微生物菌群产生延时毒性抑制作用;② 探究生化系统内活性污泥的硝化效能;③探究解决当前生化池硝化抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,化系统COD去除率50%以上且不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,COD去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  936. }
  937. ]
  938. },
  939. {
  940. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.35mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.11mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为502.97mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.20%,管控值为80%。\n池2污泥沉降比:当前值为59.11%,管控值为80%。\n池1污泥体积指数:当前值为133.03mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.84mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  941. "conversations": [
  942. {
  943. "from": "human",
  944. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  945. },
  946. {
  947. "from": "gpt",
  948. "value": "都未超过"
  949. },
  950. {
  951. "from": "human",
  952. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  953. },
  954. {
  955. "from": "gpt",
  956. "value": "否"
  957. },
  958. {
  959. "from": "human",
  960. "value": ""
  961. }
  962. ]
  963. },
  964. {
  965. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.78mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.57mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为500.51mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.74%,管控值为80%。\n池2污泥沉降比:当前值为59.74%,管控值为80%。\n池1污泥体积指数:当前值为135.65mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.09mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  966. "conversations": [
  967. {
  968. "from": "human",
  969. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  970. },
  971. {
  972. "from": "gpt",
  973. "value": "都未超过"
  974. },
  975. {
  976. "from": "human",
  977. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  978. },
  979. {
  980. "from": "gpt",
  981. "value": "是"
  982. },
  983. {
  984. "from": "human",
  985. "value": "状态:生化池有大量泡沫、浮泥等不正常现象\n由于生化池出现大量泡沫、浮泥等不正常现象,可能是污泥膨胀、老化、解絮等导致微生物活性下降,导致出水带泥。\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  986. }
  987. ]
  988. },
  989. {
  990. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.20mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.04mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为502.59mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.29%,管控值为80%。\n池2污泥沉降比:当前值为90.13%,管控值为80%。\n池1污泥体积指数:当前值为133.84mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.51mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  991. "conversations": [
  992. {
  993. "from": "human",
  994. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  995. },
  996. {
  997. "from": "gpt",
  998. "value": "至少一个池子有超过"
  999. },
  1000. {
  1001. "from": "human",
  1002. "value": "状态:污泥沉降比或污泥体积指数异常\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  1003. }
  1004. ]
  1005. },
  1006. {
  1007. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n\n出水COD:当前值为35.27mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.43mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为502.29mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.56%,管控值为80%。\n池2污泥沉降比:当前值为59.82%,管控值为80%。\n池1污泥体积指数:当前值为134.20mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.36mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1008. "conversations": [
  1009. {
  1010. "from": "human",
  1011. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  1012. },
  1013. {
  1014. "from": "gpt",
  1015. "value": "正常"
  1016. },
  1017. {
  1018. "from": "human",
  1019. "value": "出水COD是否连续两次超标?"
  1020. },
  1021. {
  1022. "from": "gpt",
  1023. "value": "存在"
  1024. },
  1025. {
  1026. "from": "human",
  1027. "value": "状态:基本确认出水COD超标了\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  1028. }
  1029. ]
  1030. },
  1031. {
  1032. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.90mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.85mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为503.34mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.65%,管控值为80%。\n池2污泥沉降比:当前值为60.57%,管控值为80%。\n池1污泥体积指数:当前值为136.75mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.34mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1033. "conversations": [
  1034. {
  1035. "from": "human",
  1036. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  1037. },
  1038. {
  1039. "from": "gpt",
  1040. "value": "正常"
  1041. },
  1042. {
  1043. "from": "human",
  1044. "value": "出水COD是否连续两次超标?"
  1045. },
  1046. {
  1047. "from": "gpt",
  1048. "value": "不存在"
  1049. },
  1050. {
  1051. "from": "human",
  1052. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  1053. },
  1054. {
  1055. "from": "gpt",
  1056. "value": "超标"
  1057. },
  1058. {
  1059. "from": "human",
  1060. "value": "状态:人工化验比对,出水COD超标了。\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  1061. }
  1062. ]
  1063. },
  1064. {
  1065. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.03mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.66mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为500.15mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.53%,管控值为80%。\n池2污泥沉降比:当前值为59.61%,管控值为80%。\n池1污泥体积指数:当前值为133.84mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.42mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1066. "conversations": [
  1067. {
  1068. "from": "human",
  1069. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  1070. },
  1071. {
  1072. "from": "gpt",
  1073. "value": "正常"
  1074. },
  1075. {
  1076. "from": "human",
  1077. "value": "出水COD是否连续两次超标?"
  1078. },
  1079. {
  1080. "from": "gpt",
  1081. "value": "不存在"
  1082. },
  1083. {
  1084. "from": "human",
  1085. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  1086. },
  1087. {
  1088. "from": "gpt",
  1089. "value": "不超标"
  1090. },
  1091. {
  1092. "from": "human",
  1093. "value": "状态:人工化验出水COD不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
  1094. }
  1095. ]
  1096. },
  1097. {
  1098. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为0.03mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.07mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为500.18mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.48%,管控值为80%。\n池2污泥沉降比:当前值为60.82%,管控值为80%。\n池1污泥体积指数:当前值为135.39mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.23mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1099. "conversations": [
  1100. {
  1101. "from": "human",
  1102. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  1103. },
  1104. {
  1105. "from": "gpt",
  1106. "value": "不正常"
  1107. },
  1108. {
  1109. "from": "human",
  1110. "value": "状态:仪表不正常\n解决方案:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
  1111. }
  1112. ]
  1113. },
  1114. {
  1115. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.25mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.25mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为500.07mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.60%,管控值为80%。\n池2污泥沉降比:当前值为60.89%,管控值为80%。\n池1污泥体积指数:当前值为134.96mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.87mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1116. "conversations": [
  1117. {
  1118. "from": "human",
  1119. "value": "进水COD高于设计值?"
  1120. },
  1121. {
  1122. "from": "gpt",
  1123. "value": "低于设计值"
  1124. },
  1125. {
  1126. "from": "human",
  1127. "value": "进水总量与设计值的比较是?"
  1128. },
  1129. {
  1130. "from": "gpt",
  1131. "value": "小于设计值"
  1132. },
  1133. {
  1134. "from": "human",
  1135. "value": ""
  1136. }
  1137. ]
  1138. },
  1139. {
  1140. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.43mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.98mg/L,设计值为630mg/L。\n进水水温:当前值是11.54℃。\n进水TDS:当前值为503.18mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.06%,管控值为80%。\n池2污泥沉降比:当前值为60.98%,管控值为80%。\n池1污泥体积指数:当前值为134.64mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.38mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1141. "conversations": [
  1142. {
  1143. "from": "human",
  1144. "value": "进水COD高于设计值?"
  1145. },
  1146. {
  1147. "from": "gpt",
  1148. "value": "低于设计值"
  1149. },
  1150. {
  1151. "from": "human",
  1152. "value": "进水总量与设计值的比较是?"
  1153. },
  1154. {
  1155. "from": "gpt",
  1156. "value": "大于但未超过110%"
  1157. },
  1158. {
  1159. "from": "human",
  1160. "value": "状态:进水COD未超设计值,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  1161. }
  1162. ]
  1163. },
  1164. {
  1165. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.53mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.68mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为503.69mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.52%,管控值为80%。\n池2污泥沉降比:当前值为60.91%,管控值为80%。\n池1污泥体积指数:当前值为135.44mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.06mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1166. "conversations": [
  1167. {
  1168. "from": "human",
  1169. "value": "进水COD高于设计值?"
  1170. },
  1171. {
  1172. "from": "gpt",
  1173. "value": "低于设计值"
  1174. },
  1175. {
  1176. "from": "human",
  1177. "value": "进水总量与设计值的比较是?"
  1178. },
  1179. {
  1180. "from": "gpt",
  1181. "value": "超过110%"
  1182. },
  1183. {
  1184. "from": "human",
  1185. "value": "状态:进水COD未超设计值,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  1186. }
  1187. ]
  1188. },
  1189. {
  1190. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.78mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为649.72mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.70mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.47%,管控值为80%。\n池2污泥沉降比:当前值为60.16%,管控值为80%。\n池1污泥体积指数:当前值为135.10mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.16mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1191. "conversations": [
  1192. {
  1193. "from": "human",
  1194. "value": "进水COD高于设计值?"
  1195. },
  1196. {
  1197. "from": "gpt",
  1198. "value": "高于设计值但是低于110%"
  1199. },
  1200. {
  1201. "from": "human",
  1202. "value": "进水总量与设计值的比较是?"
  1203. },
  1204. {
  1205. "from": "gpt",
  1206. "value": "小于设计值"
  1207. },
  1208. {
  1209. "from": "human",
  1210. "value": ""
  1211. }
  1212. ]
  1213. },
  1214. {
  1215. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.99mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为651.42mg/L,设计值为630mg/L。\n进水水温:当前值是11.52℃。\n进水TDS:当前值为501.47mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.30%,管控值为80%。\n池2污泥沉降比:当前值为60.76%,管控值为80%。\n池1污泥体积指数:当前值为133.07mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.01mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1216. "conversations": [
  1217. {
  1218. "from": "human",
  1219. "value": "进水COD高于设计值?"
  1220. },
  1221. {
  1222. "from": "gpt",
  1223. "value": "高于设计值但是低于110%"
  1224. },
  1225. {
  1226. "from": "human",
  1227. "value": "进水总量与设计值的比较是?"
  1228. },
  1229. {
  1230. "from": "gpt",
  1231. "value": "大于但未超过110%"
  1232. },
  1233. {
  1234. "from": "human",
  1235. "value": "状态:进水COD未超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  1236. }
  1237. ]
  1238. },
  1239. {
  1240. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.21mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为650.76mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为501.97mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.72%,管控值为80%。\n池2污泥沉降比:当前值为59.22%,管控值为80%。\n池1污泥体积指数:当前值为134.18mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.80mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1241. "conversations": [
  1242. {
  1243. "from": "human",
  1244. "value": "进水COD高于设计值?"
  1245. },
  1246. {
  1247. "from": "gpt",
  1248. "value": "高于设计值但是低于110%"
  1249. },
  1250. {
  1251. "from": "human",
  1252. "value": "进水总量与设计值的比较是?"
  1253. },
  1254. {
  1255. "from": "gpt",
  1256. "value": "超过110%"
  1257. },
  1258. {
  1259. "from": "human",
  1260. "value": "状态:进水COD未超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  1261. }
  1262. ]
  1263. },
  1264. {
  1265. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.51mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.09mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为500.67mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.59%,管控值为80%。\n池2污泥沉降比:当前值为60.41%,管控值为80%。\n池1污泥体积指数:当前值为134.80mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.15mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1266. "conversations": [
  1267. {
  1268. "from": "human",
  1269. "value": "进水COD高于设计值?"
  1270. },
  1271. {
  1272. "from": "gpt",
  1273. "value": "高于设计值110%"
  1274. },
  1275. {
  1276. "from": "human",
  1277. "value": "进水总量与设计值的比较是?"
  1278. },
  1279. {
  1280. "from": "gpt",
  1281. "value": "小于设计值"
  1282. },
  1283. {
  1284. "from": "human",
  1285. "value": ""
  1286. }
  1287. ]
  1288. },
  1289. {
  1290. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.48mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.12mg/L,设计值为630mg/L。\n进水水温:当前值是11.52℃。\n进水TDS:当前值为503.71mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.58%,管控值为80%。\n池2污泥沉降比:当前值为59.58%,管控值为80%。\n池1污泥体积指数:当前值为133.83mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.71mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1291. "conversations": [
  1292. {
  1293. "from": "human",
  1294. "value": "进水COD高于设计值?"
  1295. },
  1296. {
  1297. "from": "gpt",
  1298. "value": "高于设计值110%"
  1299. },
  1300. {
  1301. "from": "human",
  1302. "value": "进水总量与设计值的比较是?"
  1303. },
  1304. {
  1305. "from": "gpt",
  1306. "value": "大于但未超过110%"
  1307. },
  1308. {
  1309. "from": "human",
  1310. "value": "状态:进水COD超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  1311. }
  1312. ]
  1313. },
  1314. {
  1315. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.53mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.76mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为502.09mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.83%,管控值为80%。\n池2污泥沉降比:当前值为59.82%,管控值为80%。\n池1污泥体积指数:当前值为134.64mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.84mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1316. "conversations": [
  1317. {
  1318. "from": "human",
  1319. "value": "进水COD高于设计值?"
  1320. },
  1321. {
  1322. "from": "gpt",
  1323. "value": "高于设计值110%"
  1324. },
  1325. {
  1326. "from": "human",
  1327. "value": "进水总量与设计值的比较是?"
  1328. },
  1329. {
  1330. "from": "gpt",
  1331. "value": "超过110%"
  1332. },
  1333. {
  1334. "from": "human",
  1335. "value": "状态:进水COD超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  1336. }
  1337. ]
  1338. },
  1339. {
  1340. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.54mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.10mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为503.27mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.91%,管控值为80%。\n池2污泥沉降比:当前值为60.36%,管控值为80%。\n池1污泥体积指数:当前值为135.56mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.51mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为3.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1341. "conversations": [
  1342. {
  1343. "from": "human",
  1344. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  1345. },
  1346. {
  1347. "from": "gpt",
  1348. "value": "都未低于"
  1349. },
  1350. {
  1351. "from": "human",
  1352. "value": ""
  1353. }
  1354. ]
  1355. },
  1356. {
  1357. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.75mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.98mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为500.62mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.79%,管控值为80%。\n池2污泥沉降比:当前值为59.50%,管控值为80%。\n池1污泥体积指数:当前值为135.11mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.50mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1358. "conversations": [
  1359. {
  1360. "from": "human",
  1361. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  1362. },
  1363. {
  1364. "from": "gpt",
  1365. "value": "至少一个池子有低于"
  1366. },
  1367. {
  1368. "from": "human",
  1369. "value": "状态:好氧池溶解氧偏低\n解决方案:\n1、解决供风量不足导致的生化池DO过低\n首先查看风机状态,尝试提高已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,启动或切换备用风机,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决曝气管路不畅、漏气等导致的生化池DO过低\n(1)定期及时排出曝气管路中的领凝水保障管路通常。(2)水面上漏点直接维修;水面下漏点,具备停进水条件的放空后维修,不具备的则按环保要求完成备案同意后,争取最短时间内恢复,在此期间根据实际情况灵活采取过渡措施予以保障。\n3、供风量充足,解决曝气器破损或脱落等导致的生化池DO过低\n关闭或调小泄漏处阀门,减小气量损失,保障生化池充氧效果。具备停水放空条件,及时维修或更换。在此期间根据实际情况灵活采取过渡措施予以保障。\n4、供风量充足,解决生化池负或液位差异导致生化池气量分配不均导致的DO过低\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
  1370. }
  1371. ]
  1372. },
  1373. {
  1374. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.60mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.07mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为502.04mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.79%,管控值为80%。\n池2污泥沉降比:当前值为60.61%,管控值为80%。\n池1污泥体积指数:当前值为134.81mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.37mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1375. "conversations": [
  1376. {
  1377. "from": "human",
  1378. "value": "进水水温是否小于8℃"
  1379. },
  1380. {
  1381. "from": "gpt",
  1382. "value": "否"
  1383. },
  1384. {
  1385. "from": "human",
  1386. "value": ""
  1387. }
  1388. ]
  1389. },
  1390. {
  1391. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.72mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.96mg/L,设计值为630mg/L。\n\n进水水温:当前值是3.50℃。\n进水TDS:当前值为502.21mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.32%,管控值为80%。\n池2污泥沉降比:当前值为59.73%,管控值为80%。\n池1污泥体积指数:当前值为133.12mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.01mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1392. "conversations": [
  1393. {
  1394. "from": "human",
  1395. "value": "进水水温是否小于8℃"
  1396. },
  1397. {
  1398. "from": "gpt",
  1399. "value": "是"
  1400. },
  1401. {
  1402. "from": "human",
  1403. "value": "状态:进水水温小于8℃\n由于水温低于10℃,聚磷菌在低温时生长速度会减慢,生物除磷速率将会迅速下降,微生物活性下降。\n解决方案:\n1、强化温降数据收集与分析,提前预警管控\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时,加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n(1)适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(COD不超过150mg/L)情况下,也可控制在20~25天。\n(2)合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n(3)及时调控回流比,温降或换季期间,较常规运行阶段要适当提高外回流比,一般不超过150%。内回流比则根据总氮变化灵活调整,内外总回流比不宜超过400%。"
  1404. }
  1405. ]
  1406. },
  1407. {
  1408. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.35mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.05mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为501.30mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.85%,管控值为80%。\n池2污泥沉降比:当前值为60.66%,管控值为80%。\n池1污泥体积指数:当前值为135.04mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.18mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1409. "conversations": [
  1410. {
  1411. "from": "human",
  1412. "value": "进水TDS是否超出管控值?"
  1413. },
  1414. {
  1415. "from": "gpt",
  1416. "value": "未超出"
  1417. },
  1418. {
  1419. "from": "human",
  1420. "value": ""
  1421. }
  1422. ]
  1423. },
  1424. {
  1425. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.24mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.56mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为653.53mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.47%,管控值为80%。\n池2污泥沉降比:当前值为60.84%,管控值为80%。\n池1污泥体积指数:当前值为133.90mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.32mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1426. "conversations": [
  1427. {
  1428. "from": "human",
  1429. "value": "进水TDS是否超出管控值?"
  1430. },
  1431. {
  1432. "from": "gpt",
  1433. "value": "超出"
  1434. },
  1435. {
  1436. "from": "human",
  1437. "value": "状态:进水TDS超过管控值\n解决方案:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争在第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力。\n3、毒性小试实验方案\n将现有生化系统活性污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下开展闷曝小试实验,每 8h 取样 1 次,24h 换水 1 次(换水量为 50%),连续运行 72h,比较不同进水 COD、NH3-N 污染物去除效率,根据实验结果确定:① 探究污水厂进水是否对活性良好的微生物菌群产生延时毒性抑制作用;② 探究生化系统内活性污泥的硝化效能;③探究解决当前生化池硝化抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,化系统COD去除率50%以上且不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,COD去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  1438. }
  1439. ]
  1440. },
  1441. {
  1442. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.59mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.87mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为500.59mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.14%,管控值为80%。\n池2污泥沉降比:当前值为59.05%,管控值为80%。\n池1污泥体积指数:当前值为135.55mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.27mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1443. "conversations": [
  1444. {
  1445. "from": "human",
  1446. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  1447. },
  1448. {
  1449. "from": "gpt",
  1450. "value": "都未超过"
  1451. },
  1452. {
  1453. "from": "human",
  1454. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  1455. },
  1456. {
  1457. "from": "gpt",
  1458. "value": "否"
  1459. },
  1460. {
  1461. "from": "human",
  1462. "value": ""
  1463. }
  1464. ]
  1465. },
  1466. {
  1467. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.04mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.59mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为503.56mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.24%,管控值为80%。\n池2污泥沉降比:当前值为60.44%,管控值为80%。\n池1污泥体积指数:当前值为133.05mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.17mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1468. "conversations": [
  1469. {
  1470. "from": "human",
  1471. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  1472. },
  1473. {
  1474. "from": "gpt",
  1475. "value": "都未超过"
  1476. },
  1477. {
  1478. "from": "human",
  1479. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  1480. },
  1481. {
  1482. "from": "gpt",
  1483. "value": "是"
  1484. },
  1485. {
  1486. "from": "human",
  1487. "value": "状态:生化池有大量泡沫、浮泥等不正常现象\n由于生化池出现大量泡沫、浮泥等不正常现象,可能是污泥膨胀、老化、解絮等导致微生物活性下降,导致出水带泥。\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  1488. }
  1489. ]
  1490. },
  1491. {
  1492. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.02mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.90mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为501.08mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.34%,管控值为80%。\n池2污泥沉降比:当前值为89.23%,管控值为80%。\n池1污泥体积指数:当前值为133.02mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.55mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1493. "conversations": [
  1494. {
  1495. "from": "human",
  1496. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  1497. },
  1498. {
  1499. "from": "gpt",
  1500. "value": "至少一个池子有超过"
  1501. },
  1502. {
  1503. "from": "human",
  1504. "value": "状态:污泥沉降比或污泥体积指数异常\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  1505. }
  1506. ]
  1507. },
  1508. {
  1509. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n\n出水COD:当前值为35.84mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.29mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为501.71mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.70%,管控值为80%。\n池2污泥沉降比:当前值为60.41%,管控值为80%。\n池1污泥体积指数:当前值为136.59mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.94mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1510. "conversations": [
  1511. {
  1512. "from": "human",
  1513. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  1514. },
  1515. {
  1516. "from": "gpt",
  1517. "value": "正常"
  1518. },
  1519. {
  1520. "from": "human",
  1521. "value": "出水COD是否连续两次超标?"
  1522. },
  1523. {
  1524. "from": "gpt",
  1525. "value": "存在"
  1526. },
  1527. {
  1528. "from": "human",
  1529. "value": "状态:基本确认出水COD超标了\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  1530. }
  1531. ]
  1532. },
  1533. {
  1534. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.90mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.26mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为501.63mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.45%,管控值为80%。\n池2污泥沉降比:当前值为59.46%,管控值为80%。\n池1污泥体积指数:当前值为133.06mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.88mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1535. "conversations": [
  1536. {
  1537. "from": "human",
  1538. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  1539. },
  1540. {
  1541. "from": "gpt",
  1542. "value": "正常"
  1543. },
  1544. {
  1545. "from": "human",
  1546. "value": "出水COD是否连续两次超标?"
  1547. },
  1548. {
  1549. "from": "gpt",
  1550. "value": "不存在"
  1551. },
  1552. {
  1553. "from": "human",
  1554. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  1555. },
  1556. {
  1557. "from": "gpt",
  1558. "value": "超标"
  1559. },
  1560. {
  1561. "from": "human",
  1562. "value": "状态:人工化验比对,出水COD超标了。\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  1563. }
  1564. ]
  1565. },
  1566. {
  1567. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.99mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.86mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为503.21mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.81%,管控值为80%。\n池2污泥沉降比:当前值为60.47%,管控值为80%。\n池1污泥体积指数:当前值为133.96mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.80mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1568. "conversations": [
  1569. {
  1570. "from": "human",
  1571. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  1572. },
  1573. {
  1574. "from": "gpt",
  1575. "value": "正常"
  1576. },
  1577. {
  1578. "from": "human",
  1579. "value": "出水COD是否连续两次超标?"
  1580. },
  1581. {
  1582. "from": "gpt",
  1583. "value": "不存在"
  1584. },
  1585. {
  1586. "from": "human",
  1587. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  1588. },
  1589. {
  1590. "from": "gpt",
  1591. "value": "不超标"
  1592. },
  1593. {
  1594. "from": "human",
  1595. "value": "状态:人工化验出水COD不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
  1596. }
  1597. ]
  1598. },
  1599. {
  1600. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为-0.01mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.28mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为501.09mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.06%,管控值为80%。\n池2污泥沉降比:当前值为59.29%,管控值为80%。\n池1污泥体积指数:当前值为134.75mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.25mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1601. "conversations": [
  1602. {
  1603. "from": "human",
  1604. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  1605. },
  1606. {
  1607. "from": "gpt",
  1608. "value": "不正常"
  1609. },
  1610. {
  1611. "from": "human",
  1612. "value": "状态:仪表不正常\n解决方案:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
  1613. }
  1614. ]
  1615. },
  1616. {
  1617. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.65mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.70mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为500.94mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.26%,管控值为80%。\n池2污泥沉降比:当前值为59.01%,管控值为80%。\n池1污泥体积指数:当前值为134.56mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.83mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1618. "conversations": [
  1619. {
  1620. "from": "human",
  1621. "value": "进水COD高于设计值?"
  1622. },
  1623. {
  1624. "from": "gpt",
  1625. "value": "低于设计值"
  1626. },
  1627. {
  1628. "from": "human",
  1629. "value": "进水总量与设计值的比较是?"
  1630. },
  1631. {
  1632. "from": "gpt",
  1633. "value": "小于设计值"
  1634. },
  1635. {
  1636. "from": "human",
  1637. "value": ""
  1638. }
  1639. ]
  1640. },
  1641. {
  1642. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.52mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.81mg/L,设计值为630mg/L。\n进水水温:当前值是11.50℃。\n进水TDS:当前值为503.23mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.21%,管控值为80%。\n池2污泥沉降比:当前值为59.31%,管控值为80%。\n池1污泥体积指数:当前值为134.96mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.01mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1643. "conversations": [
  1644. {
  1645. "from": "human",
  1646. "value": "进水COD高于设计值?"
  1647. },
  1648. {
  1649. "from": "gpt",
  1650. "value": "低于设计值"
  1651. },
  1652. {
  1653. "from": "human",
  1654. "value": "进水总量与设计值的比较是?"
  1655. },
  1656. {
  1657. "from": "gpt",
  1658. "value": "大于但未超过110%"
  1659. },
  1660. {
  1661. "from": "human",
  1662. "value": "状态:进水COD未超设计值,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  1663. }
  1664. ]
  1665. },
  1666. {
  1667. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.82mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.82mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为500.74mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.50%,管控值为80%。\n池2污泥沉降比:当前值为59.11%,管控值为80%。\n池1污泥体积指数:当前值为135.52mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.58mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1668. "conversations": [
  1669. {
  1670. "from": "human",
  1671. "value": "进水COD高于设计值?"
  1672. },
  1673. {
  1674. "from": "gpt",
  1675. "value": "低于设计值"
  1676. },
  1677. {
  1678. "from": "human",
  1679. "value": "进水总量与设计值的比较是?"
  1680. },
  1681. {
  1682. "from": "gpt",
  1683. "value": "超过110%"
  1684. },
  1685. {
  1686. "from": "human",
  1687. "value": "状态:进水COD未超设计值,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  1688. }
  1689. ]
  1690. },
  1691. {
  1692. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为37.00mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为651.16mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为502.65mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.15%,管控值为80%。\n池2污泥沉降比:当前值为59.59%,管控值为80%。\n池1污泥体积指数:当前值为133.49mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.19mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1693. "conversations": [
  1694. {
  1695. "from": "human",
  1696. "value": "进水COD高于设计值?"
  1697. },
  1698. {
  1699. "from": "gpt",
  1700. "value": "高于设计值但是低于110%"
  1701. },
  1702. {
  1703. "from": "human",
  1704. "value": "进水总量与设计值的比较是?"
  1705. },
  1706. {
  1707. "from": "gpt",
  1708. "value": "小于设计值"
  1709. },
  1710. {
  1711. "from": "human",
  1712. "value": ""
  1713. }
  1714. ]
  1715. },
  1716. {
  1717. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.98mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为649.06mg/L,设计值为630mg/L。\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.09mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.76%,管控值为80%。\n池2污泥沉降比:当前值为60.66%,管控值为80%。\n池1污泥体积指数:当前值为133.76mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.42mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1718. "conversations": [
  1719. {
  1720. "from": "human",
  1721. "value": "进水COD高于设计值?"
  1722. },
  1723. {
  1724. "from": "gpt",
  1725. "value": "高于设计值但是低于110%"
  1726. },
  1727. {
  1728. "from": "human",
  1729. "value": "进水总量与设计值的比较是?"
  1730. },
  1731. {
  1732. "from": "gpt",
  1733. "value": "大于但未超过110%"
  1734. },
  1735. {
  1736. "from": "human",
  1737. "value": "状态:进水COD未超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  1738. }
  1739. ]
  1740. },
  1741. {
  1742. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.31mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为648.97mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为501.83mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.73%,管控值为80%。\n池2污泥沉降比:当前值为59.37%,管控值为80%。\n池1污泥体积指数:当前值为134.82mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.75mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1743. "conversations": [
  1744. {
  1745. "from": "human",
  1746. "value": "进水COD高于设计值?"
  1747. },
  1748. {
  1749. "from": "gpt",
  1750. "value": "高于设计值但是低于110%"
  1751. },
  1752. {
  1753. "from": "human",
  1754. "value": "进水总量与设计值的比较是?"
  1755. },
  1756. {
  1757. "from": "gpt",
  1758. "value": "超过110%"
  1759. },
  1760. {
  1761. "from": "human",
  1762. "value": "状态:进水COD未超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  1763. }
  1764. ]
  1765. },
  1766. {
  1767. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.87mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.78mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为501.12mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.82%,管控值为80%。\n池2污泥沉降比:当前值为60.71%,管控值为80%。\n池1污泥体积指数:当前值为135.18mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.81mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1768. "conversations": [
  1769. {
  1770. "from": "human",
  1771. "value": "进水COD高于设计值?"
  1772. },
  1773. {
  1774. "from": "gpt",
  1775. "value": "高于设计值110%"
  1776. },
  1777. {
  1778. "from": "human",
  1779. "value": "进水总量与设计值的比较是?"
  1780. },
  1781. {
  1782. "from": "gpt",
  1783. "value": "小于设计值"
  1784. },
  1785. {
  1786. "from": "human",
  1787. "value": ""
  1788. }
  1789. ]
  1790. },
  1791. {
  1792. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.26mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.40mg/L,设计值为630mg/L。\n进水水温:当前值是11.53℃。\n进水TDS:当前值为503.31mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.74%,管控值为80%。\n池2污泥沉降比:当前值为59.54%,管控值为80%。\n池1污泥体积指数:当前值为134.78mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.45mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1793. "conversations": [
  1794. {
  1795. "from": "human",
  1796. "value": "进水COD高于设计值?"
  1797. },
  1798. {
  1799. "from": "gpt",
  1800. "value": "高于设计值110%"
  1801. },
  1802. {
  1803. "from": "human",
  1804. "value": "进水总量与设计值的比较是?"
  1805. },
  1806. {
  1807. "from": "gpt",
  1808. "value": "大于但未超过110%"
  1809. },
  1810. {
  1811. "from": "human",
  1812. "value": "状态:进水COD超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  1813. }
  1814. ]
  1815. },
  1816. {
  1817. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.09mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.82mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为501.04mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.25%,管控值为80%。\n池2污泥沉降比:当前值为60.59%,管控值为80%。\n池1污泥体积指数:当前值为133.52mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.59mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1818. "conversations": [
  1819. {
  1820. "from": "human",
  1821. "value": "进水COD高于设计值?"
  1822. },
  1823. {
  1824. "from": "gpt",
  1825. "value": "高于设计值110%"
  1826. },
  1827. {
  1828. "from": "human",
  1829. "value": "进水总量与设计值的比较是?"
  1830. },
  1831. {
  1832. "from": "gpt",
  1833. "value": "超过110%"
  1834. },
  1835. {
  1836. "from": "human",
  1837. "value": "状态:进水COD超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  1838. }
  1839. ]
  1840. },
  1841. {
  1842. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.77mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.81mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为502.56mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.70%,管控值为80%。\n池2污泥沉降比:当前值为59.53%,管控值为80%。\n池1污泥体积指数:当前值为134.26mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.17mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为3.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1843. "conversations": [
  1844. {
  1845. "from": "human",
  1846. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  1847. },
  1848. {
  1849. "from": "gpt",
  1850. "value": "都未低于"
  1851. },
  1852. {
  1853. "from": "human",
  1854. "value": ""
  1855. }
  1856. ]
  1857. },
  1858. {
  1859. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.87mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.86mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为503.12mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.74%,管控值为80%。\n池2污泥沉降比:当前值为59.59%,管控值为80%。\n池1污泥体积指数:当前值为135.36mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.16mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1860. "conversations": [
  1861. {
  1862. "from": "human",
  1863. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  1864. },
  1865. {
  1866. "from": "gpt",
  1867. "value": "至少一个池子有低于"
  1868. },
  1869. {
  1870. "from": "human",
  1871. "value": "状态:好氧池溶解氧偏低\n解决方案:\n1、解决供风量不足导致的生化池DO过低\n首先查看风机状态,尝试提高已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,启动或切换备用风机,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决曝气管路不畅、漏气等导致的生化池DO过低\n(1)定期及时排出曝气管路中的领凝水保障管路通常。(2)水面上漏点直接维修;水面下漏点,具备停进水条件的放空后维修,不具备的则按环保要求完成备案同意后,争取最短时间内恢复,在此期间根据实际情况灵活采取过渡措施予以保障。\n3、供风量充足,解决曝气器破损或脱落等导致的生化池DO过低\n关闭或调小泄漏处阀门,减小气量损失,保障生化池充氧效果。具备停水放空条件,及时维修或更换。在此期间根据实际情况灵活采取过渡措施予以保障。\n4、供风量充足,解决生化池负或液位差异导致生化池气量分配不均导致的DO过低\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
  1872. }
  1873. ]
  1874. },
  1875. {
  1876. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.67mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.00mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为500.42mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.97%,管控值为80%。\n池2污泥沉降比:当前值为60.08%,管控值为80%。\n池1污泥体积指数:当前值为134.05mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.95mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1877. "conversations": [
  1878. {
  1879. "from": "human",
  1880. "value": "进水水温是否小于8℃"
  1881. },
  1882. {
  1883. "from": "gpt",
  1884. "value": "否"
  1885. },
  1886. {
  1887. "from": "human",
  1888. "value": ""
  1889. }
  1890. ]
  1891. },
  1892. {
  1893. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.40mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.60mg/L,设计值为630mg/L。\n\n进水水温:当前值是3.51℃。\n进水TDS:当前值为501.99mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.25%,管控值为80%。\n池2污泥沉降比:当前值为60.58%,管控值为80%。\n池1污泥体积指数:当前值为134.86mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.17mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1894. "conversations": [
  1895. {
  1896. "from": "human",
  1897. "value": "进水水温是否小于8℃"
  1898. },
  1899. {
  1900. "from": "gpt",
  1901. "value": "是"
  1902. },
  1903. {
  1904. "from": "human",
  1905. "value": "状态:进水水温小于8℃\n由于水温低于10℃,聚磷菌在低温时生长速度会减慢,生物除磷速率将会迅速下降,微生物活性下降。\n解决方案:\n1、强化温降数据收集与分析,提前预警管控\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时,加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n(1)适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(COD不超过150mg/L)情况下,也可控制在20~25天。\n(2)合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n(3)及时调控回流比,温降或换季期间,较常规运行阶段要适当提高外回流比,一般不超过150%。内回流比则根据总氮变化灵活调整,内外总回流比不宜超过400%。"
  1906. }
  1907. ]
  1908. },
  1909. {
  1910. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.94mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.50mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为500.21mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.89%,管控值为80%。\n池2污泥沉降比:当前值为59.84%,管控值为80%。\n池1污泥体积指数:当前值为136.07mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.78mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1911. "conversations": [
  1912. {
  1913. "from": "human",
  1914. "value": "进水TDS是否超出管控值?"
  1915. },
  1916. {
  1917. "from": "gpt",
  1918. "value": "未超出"
  1919. },
  1920. {
  1921. "from": "human",
  1922. "value": ""
  1923. }
  1924. ]
  1925. },
  1926. {
  1927. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.52mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.42mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为652.17mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.38%,管控值为80%。\n池2污泥沉降比:当前值为59.07%,管控值为80%。\n池1污泥体积指数:当前值为135.03mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.92mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1928. "conversations": [
  1929. {
  1930. "from": "human",
  1931. "value": "进水TDS是否超出管控值?"
  1932. },
  1933. {
  1934. "from": "gpt",
  1935. "value": "超出"
  1936. },
  1937. {
  1938. "from": "human",
  1939. "value": "状态:进水TDS超过管控值\n解决方案:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争在第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力。\n3、毒性小试实验方案\n将现有生化系统活性污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下开展闷曝小试实验,每 8h 取样 1 次,24h 换水 1 次(换水量为 50%),连续运行 72h,比较不同进水 COD、NH3-N 污染物去除效率,根据实验结果确定:① 探究污水厂进水是否对活性良好的微生物菌群产生延时毒性抑制作用;② 探究生化系统内活性污泥的硝化效能;③探究解决当前生化池硝化抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,化系统COD去除率50%以上且不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,COD去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  1940. }
  1941. ]
  1942. },
  1943. {
  1944. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.67mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.46mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为503.24mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.82%,管控值为80%。\n池2污泥沉降比:当前值为60.11%,管控值为80%。\n池1污泥体积指数:当前值为135.84mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.67mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1945. "conversations": [
  1946. {
  1947. "from": "human",
  1948. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  1949. },
  1950. {
  1951. "from": "gpt",
  1952. "value": "都未超过"
  1953. },
  1954. {
  1955. "from": "human",
  1956. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  1957. },
  1958. {
  1959. "from": "gpt",
  1960. "value": "否"
  1961. },
  1962. {
  1963. "from": "human",
  1964. "value": ""
  1965. }
  1966. ]
  1967. },
  1968. {
  1969. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.29mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.83mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为500.43mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.50%,管控值为80%。\n池2污泥沉降比:当前值为59.63%,管控值为80%。\n池1污泥体积指数:当前值为134.89mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.60mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1970. "conversations": [
  1971. {
  1972. "from": "human",
  1973. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  1974. },
  1975. {
  1976. "from": "gpt",
  1977. "value": "都未超过"
  1978. },
  1979. {
  1980. "from": "human",
  1981. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  1982. },
  1983. {
  1984. "from": "gpt",
  1985. "value": "是"
  1986. },
  1987. {
  1988. "from": "human",
  1989. "value": "状态:生化池有大量泡沫、浮泥等不正常现象\n由于生化池出现大量泡沫、浮泥等不正常现象,可能是污泥膨胀、老化、解絮等导致微生物活性下降,导致出水带泥。\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  1990. }
  1991. ]
  1992. },
  1993. {
  1994. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.57mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.77mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为500.87mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.50%,管控值为80%。\n池2污泥沉降比:当前值为90.68%,管控值为80%。\n池1污泥体积指数:当前值为134.03mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.42mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  1995. "conversations": [
  1996. {
  1997. "from": "human",
  1998. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  1999. },
  2000. {
  2001. "from": "gpt",
  2002. "value": "至少一个池子有超过"
  2003. },
  2004. {
  2005. "from": "human",
  2006. "value": "状态:污泥沉降比或污泥体积指数异常\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  2007. }
  2008. ]
  2009. },
  2010. {
  2011. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n\n出水COD:当前值为35.73mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.91mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为502.21mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.91%,管控值为80%。\n池2污泥沉降比:当前值为60.24%,管控值为80%。\n池1污泥体积指数:当前值为134.27mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.87mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2012. "conversations": [
  2013. {
  2014. "from": "human",
  2015. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  2016. },
  2017. {
  2018. "from": "gpt",
  2019. "value": "正常"
  2020. },
  2021. {
  2022. "from": "human",
  2023. "value": "出水COD是否连续两次超标?"
  2024. },
  2025. {
  2026. "from": "gpt",
  2027. "value": "存在"
  2028. },
  2029. {
  2030. "from": "human",
  2031. "value": "状态:基本确认出水COD超标了\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  2032. }
  2033. ]
  2034. },
  2035. {
  2036. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.15mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.77mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为501.52mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.69%,管控值为80%。\n池2污泥沉降比:当前值为59.40%,管控值为80%。\n池1污泥体积指数:当前值为134.07mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.05mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2037. "conversations": [
  2038. {
  2039. "from": "human",
  2040. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  2041. },
  2042. {
  2043. "from": "gpt",
  2044. "value": "正常"
  2045. },
  2046. {
  2047. "from": "human",
  2048. "value": "出水COD是否连续两次超标?"
  2049. },
  2050. {
  2051. "from": "gpt",
  2052. "value": "不存在"
  2053. },
  2054. {
  2055. "from": "human",
  2056. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  2057. },
  2058. {
  2059. "from": "gpt",
  2060. "value": "超标"
  2061. },
  2062. {
  2063. "from": "human",
  2064. "value": "状态:人工化验比对,出水COD超标了。\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  2065. }
  2066. ]
  2067. },
  2068. {
  2069. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.79mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.24mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为503.37mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.31%,管控值为80%。\n池2污泥沉降比:当前值为61.00%,管控值为80%。\n池1污泥体积指数:当前值为135.37mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.93mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2070. "conversations": [
  2071. {
  2072. "from": "human",
  2073. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  2074. },
  2075. {
  2076. "from": "gpt",
  2077. "value": "正常"
  2078. },
  2079. {
  2080. "from": "human",
  2081. "value": "出水COD是否连续两次超标?"
  2082. },
  2083. {
  2084. "from": "gpt",
  2085. "value": "不存在"
  2086. },
  2087. {
  2088. "from": "human",
  2089. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  2090. },
  2091. {
  2092. "from": "gpt",
  2093. "value": "不超标"
  2094. },
  2095. {
  2096. "from": "human",
  2097. "value": "状态:人工化验出水COD不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
  2098. }
  2099. ]
  2100. },
  2101. {
  2102. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为0.02mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.13mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为503.11mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.50%,管控值为80%。\n池2污泥沉降比:当前值为60.02%,管控值为80%。\n池1污泥体积指数:当前值为136.04mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.09mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2103. "conversations": [
  2104. {
  2105. "from": "human",
  2106. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  2107. },
  2108. {
  2109. "from": "gpt",
  2110. "value": "不正常"
  2111. },
  2112. {
  2113. "from": "human",
  2114. "value": "状态:仪表不正常\n解决方案:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
  2115. }
  2116. ]
  2117. },
  2118. {
  2119. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.68mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.51mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为503.48mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.10%,管控值为80%。\n池2污泥沉降比:当前值为60.99%,管控值为80%。\n池1污泥体积指数:当前值为133.47mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.49mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2120. "conversations": [
  2121. {
  2122. "from": "human",
  2123. "value": "进水COD高于设计值?"
  2124. },
  2125. {
  2126. "from": "gpt",
  2127. "value": "低于设计值"
  2128. },
  2129. {
  2130. "from": "human",
  2131. "value": "进水总量与设计值的比较是?"
  2132. },
  2133. {
  2134. "from": "gpt",
  2135. "value": "小于设计值"
  2136. },
  2137. {
  2138. "from": "human",
  2139. "value": ""
  2140. }
  2141. ]
  2142. },
  2143. {
  2144. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.75mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.15mg/L,设计值为630mg/L。\n进水水温:当前值是11.52℃。\n进水TDS:当前值为500.89mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.18%,管控值为80%。\n池2污泥沉降比:当前值为60.14%,管控值为80%。\n池1污泥体积指数:当前值为134.94mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.57mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2145. "conversations": [
  2146. {
  2147. "from": "human",
  2148. "value": "进水COD高于设计值?"
  2149. },
  2150. {
  2151. "from": "gpt",
  2152. "value": "低于设计值"
  2153. },
  2154. {
  2155. "from": "human",
  2156. "value": "进水总量与设计值的比较是?"
  2157. },
  2158. {
  2159. "from": "gpt",
  2160. "value": "大于但未超过110%"
  2161. },
  2162. {
  2163. "from": "human",
  2164. "value": "状态:进水COD未超设计值,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  2165. }
  2166. ]
  2167. },
  2168. {
  2169. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.46mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.40mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为502.47mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.63%,管控值为80%。\n池2污泥沉降比:当前值为60.81%,管控值为80%。\n池1污泥体积指数:当前值为136.34mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.93mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2170. "conversations": [
  2171. {
  2172. "from": "human",
  2173. "value": "进水COD高于设计值?"
  2174. },
  2175. {
  2176. "from": "gpt",
  2177. "value": "低于设计值"
  2178. },
  2179. {
  2180. "from": "human",
  2181. "value": "进水总量与设计值的比较是?"
  2182. },
  2183. {
  2184. "from": "gpt",
  2185. "value": "超过110%"
  2186. },
  2187. {
  2188. "from": "human",
  2189. "value": "状态:进水COD未超设计值,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  2190. }
  2191. ]
  2192. },
  2193. {
  2194. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.34mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为648.56mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为500.91mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.31%,管控值为80%。\n池2污泥沉降比:当前值为59.23%,管控值为80%。\n池1污泥体积指数:当前值为135.69mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.47mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2195. "conversations": [
  2196. {
  2197. "from": "human",
  2198. "value": "进水COD高于设计值?"
  2199. },
  2200. {
  2201. "from": "gpt",
  2202. "value": "高于设计值但是低于110%"
  2203. },
  2204. {
  2205. "from": "human",
  2206. "value": "进水总量与设计值的比较是?"
  2207. },
  2208. {
  2209. "from": "gpt",
  2210. "value": "小于设计值"
  2211. },
  2212. {
  2213. "from": "human",
  2214. "value": ""
  2215. }
  2216. ]
  2217. },
  2218. {
  2219. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.60mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为650.49mg/L,设计值为630mg/L。\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.69mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.67%,管控值为80%。\n池2污泥沉降比:当前值为60.77%,管控值为80%。\n池1污泥体积指数:当前值为133.46mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.68mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2220. "conversations": [
  2221. {
  2222. "from": "human",
  2223. "value": "进水COD高于设计值?"
  2224. },
  2225. {
  2226. "from": "gpt",
  2227. "value": "高于设计值但是低于110%"
  2228. },
  2229. {
  2230. "from": "human",
  2231. "value": "进水总量与设计值的比较是?"
  2232. },
  2233. {
  2234. "from": "gpt",
  2235. "value": "大于但未超过110%"
  2236. },
  2237. {
  2238. "from": "human",
  2239. "value": "状态:进水COD未超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  2240. }
  2241. ]
  2242. },
  2243. {
  2244. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.89mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为651.76mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为503.40mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.93%,管控值为80%。\n池2污泥沉降比:当前值为59.98%,管控值为80%。\n池1污泥体积指数:当前值为136.77mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.81mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2245. "conversations": [
  2246. {
  2247. "from": "human",
  2248. "value": "进水COD高于设计值?"
  2249. },
  2250. {
  2251. "from": "gpt",
  2252. "value": "高于设计值但是低于110%"
  2253. },
  2254. {
  2255. "from": "human",
  2256. "value": "进水总量与设计值的比较是?"
  2257. },
  2258. {
  2259. "from": "gpt",
  2260. "value": "超过110%"
  2261. },
  2262. {
  2263. "from": "human",
  2264. "value": "状态:进水COD未超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  2265. }
  2266. ]
  2267. },
  2268. {
  2269. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.03mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.26mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为502.31mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.52%,管控值为80%。\n池2污泥沉降比:当前值为60.47%,管控值为80%。\n池1污泥体积指数:当前值为136.42mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.45mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2270. "conversations": [
  2271. {
  2272. "from": "human",
  2273. "value": "进水COD高于设计值?"
  2274. },
  2275. {
  2276. "from": "gpt",
  2277. "value": "高于设计值110%"
  2278. },
  2279. {
  2280. "from": "human",
  2281. "value": "进水总量与设计值的比较是?"
  2282. },
  2283. {
  2284. "from": "gpt",
  2285. "value": "小于设计值"
  2286. },
  2287. {
  2288. "from": "human",
  2289. "value": ""
  2290. }
  2291. ]
  2292. },
  2293. {
  2294. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.20mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.37mg/L,设计值为630mg/L。\n进水水温:当前值是11.55℃。\n进水TDS:当前值为500.84mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.58%,管控值为80%。\n池2污泥沉降比:当前值为60.56%,管控值为80%。\n池1污泥体积指数:当前值为136.53mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.30mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2295. "conversations": [
  2296. {
  2297. "from": "human",
  2298. "value": "进水COD高于设计值?"
  2299. },
  2300. {
  2301. "from": "gpt",
  2302. "value": "高于设计值110%"
  2303. },
  2304. {
  2305. "from": "human",
  2306. "value": "进水总量与设计值的比较是?"
  2307. },
  2308. {
  2309. "from": "gpt",
  2310. "value": "大于但未超过110%"
  2311. },
  2312. {
  2313. "from": "human",
  2314. "value": "状态:进水COD超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  2315. }
  2316. ]
  2317. },
  2318. {
  2319. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.71mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.11mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为503.17mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.88%,管控值为80%。\n池2污泥沉降比:当前值为60.74%,管控值为80%。\n池1污泥体积指数:当前值为135.96mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.58mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2320. "conversations": [
  2321. {
  2322. "from": "human",
  2323. "value": "进水COD高于设计值?"
  2324. },
  2325. {
  2326. "from": "gpt",
  2327. "value": "高于设计值110%"
  2328. },
  2329. {
  2330. "from": "human",
  2331. "value": "进水总量与设计值的比较是?"
  2332. },
  2333. {
  2334. "from": "gpt",
  2335. "value": "超过110%"
  2336. },
  2337. {
  2338. "from": "human",
  2339. "value": "状态:进水COD超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  2340. }
  2341. ]
  2342. },
  2343. {
  2344. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.30mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.74mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为500.26mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.08%,管控值为80%。\n池2污泥沉降比:当前值为59.93%,管控值为80%。\n池1污泥体积指数:当前值为133.48mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.79mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为3.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2345. "conversations": [
  2346. {
  2347. "from": "human",
  2348. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  2349. },
  2350. {
  2351. "from": "gpt",
  2352. "value": "都未低于"
  2353. },
  2354. {
  2355. "from": "human",
  2356. "value": ""
  2357. }
  2358. ]
  2359. },
  2360. {
  2361. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.16mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.82mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为501.47mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.50%,管控值为80%。\n池2污泥沉降比:当前值为60.88%,管控值为80%。\n池1污泥体积指数:当前值为136.12mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.40mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2362. "conversations": [
  2363. {
  2364. "from": "human",
  2365. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  2366. },
  2367. {
  2368. "from": "gpt",
  2369. "value": "至少一个池子有低于"
  2370. },
  2371. {
  2372. "from": "human",
  2373. "value": "状态:好氧池溶解氧偏低\n解决方案:\n1、解决供风量不足导致的生化池DO过低\n首先查看风机状态,尝试提高已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,启动或切换备用风机,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决曝气管路不畅、漏气等导致的生化池DO过低\n(1)定期及时排出曝气管路中的领凝水保障管路通常。(2)水面上漏点直接维修;水面下漏点,具备停进水条件的放空后维修,不具备的则按环保要求完成备案同意后,争取最短时间内恢复,在此期间根据实际情况灵活采取过渡措施予以保障。\n3、供风量充足,解决曝气器破损或脱落等导致的生化池DO过低\n关闭或调小泄漏处阀门,减小气量损失,保障生化池充氧效果。具备停水放空条件,及时维修或更换。在此期间根据实际情况灵活采取过渡措施予以保障。\n4、供风量充足,解决生化池负或液位差异导致生化池气量分配不均导致的DO过低\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
  2374. }
  2375. ]
  2376. },
  2377. {
  2378. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.25mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.63mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为500.56mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.80%,管控值为80%。\n池2污泥沉降比:当前值为60.93%,管控值为80%。\n池1污泥体积指数:当前值为134.98mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.04mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2379. "conversations": [
  2380. {
  2381. "from": "human",
  2382. "value": "进水水温是否小于8℃"
  2383. },
  2384. {
  2385. "from": "gpt",
  2386. "value": "否"
  2387. },
  2388. {
  2389. "from": "human",
  2390. "value": ""
  2391. }
  2392. ]
  2393. },
  2394. {
  2395. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.20mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.16mg/L,设计值为630mg/L。\n\n进水水温:当前值是3.51℃。\n进水TDS:当前值为501.48mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.52%,管控值为80%。\n池2污泥沉降比:当前值为59.68%,管控值为80%。\n池1污泥体积指数:当前值为135.35mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.64mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2396. "conversations": [
  2397. {
  2398. "from": "human",
  2399. "value": "进水水温是否小于8℃"
  2400. },
  2401. {
  2402. "from": "gpt",
  2403. "value": "是"
  2404. },
  2405. {
  2406. "from": "human",
  2407. "value": "状态:进水水温小于8℃\n由于水温低于10℃,聚磷菌在低温时生长速度会减慢,生物除磷速率将会迅速下降,微生物活性下降。\n解决方案:\n1、强化温降数据收集与分析,提前预警管控\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时,加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n(1)适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(COD不超过150mg/L)情况下,也可控制在20~25天。\n(2)合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n(3)及时调控回流比,温降或换季期间,较常规运行阶段要适当提高外回流比,一般不超过150%。内回流比则根据总氮变化灵活调整,内外总回流比不宜超过400%。"
  2408. }
  2409. ]
  2410. },
  2411. {
  2412. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.35mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.22mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为500.59mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.64%,管控值为80%。\n池2污泥沉降比:当前值为59.07%,管控值为80%。\n池1污泥体积指数:当前值为133.35mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.03mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2413. "conversations": [
  2414. {
  2415. "from": "human",
  2416. "value": "进水TDS是否超出管控值?"
  2417. },
  2418. {
  2419. "from": "gpt",
  2420. "value": "未超出"
  2421. },
  2422. {
  2423. "from": "human",
  2424. "value": ""
  2425. }
  2426. ]
  2427. },
  2428. {
  2429. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.49mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.05mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为651.50mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.02%,管控值为80%。\n池2污泥沉降比:当前值为59.66%,管控值为80%。\n池1污泥体积指数:当前值为135.25mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.09mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2430. "conversations": [
  2431. {
  2432. "from": "human",
  2433. "value": "进水TDS是否超出管控值?"
  2434. },
  2435. {
  2436. "from": "gpt",
  2437. "value": "超出"
  2438. },
  2439. {
  2440. "from": "human",
  2441. "value": "状态:进水TDS超过管控值\n解决方案:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争在第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力。\n3、毒性小试实验方案\n将现有生化系统活性污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下开展闷曝小试实验,每 8h 取样 1 次,24h 换水 1 次(换水量为 50%),连续运行 72h,比较不同进水 COD、NH3-N 污染物去除效率,根据实验结果确定:① 探究污水厂进水是否对活性良好的微生物菌群产生延时毒性抑制作用;② 探究生化系统内活性污泥的硝化效能;③探究解决当前生化池硝化抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,化系统COD去除率50%以上且不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,COD去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  2442. }
  2443. ]
  2444. },
  2445. {
  2446. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.67mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.68mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为501.90mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.25%,管控值为80%。\n池2污泥沉降比:当前值为60.35%,管控值为80%。\n池1污泥体积指数:当前值为134.04mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.74mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2447. "conversations": [
  2448. {
  2449. "from": "human",
  2450. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  2451. },
  2452. {
  2453. "from": "gpt",
  2454. "value": "都未超过"
  2455. },
  2456. {
  2457. "from": "human",
  2458. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  2459. },
  2460. {
  2461. "from": "gpt",
  2462. "value": "否"
  2463. },
  2464. {
  2465. "from": "human",
  2466. "value": ""
  2467. }
  2468. ]
  2469. },
  2470. {
  2471. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.23mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.85mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为503.81mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.62%,管控值为80%。\n池2污泥沉降比:当前值为60.21%,管控值为80%。\n池1污泥体积指数:当前值为136.35mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.40mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2472. "conversations": [
  2473. {
  2474. "from": "human",
  2475. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  2476. },
  2477. {
  2478. "from": "gpt",
  2479. "value": "都未超过"
  2480. },
  2481. {
  2482. "from": "human",
  2483. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  2484. },
  2485. {
  2486. "from": "gpt",
  2487. "value": "是"
  2488. },
  2489. {
  2490. "from": "human",
  2491. "value": "状态:生化池有大量泡沫、浮泥等不正常现象\n由于生化池出现大量泡沫、浮泥等不正常现象,可能是污泥膨胀、老化、解絮等导致微生物活性下降,导致出水带泥。\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  2492. }
  2493. ]
  2494. },
  2495. {
  2496. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.30mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.15mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为503.12mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.65%,管控值为80%。\n池2污泥沉降比:当前值为90.14%,管控值为80%。\n池1污泥体积指数:当前值为133.20mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.59mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2497. "conversations": [
  2498. {
  2499. "from": "human",
  2500. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  2501. },
  2502. {
  2503. "from": "gpt",
  2504. "value": "至少一个池子有超过"
  2505. },
  2506. {
  2507. "from": "human",
  2508. "value": "状态:污泥沉降比或污泥体积指数异常\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  2509. }
  2510. ]
  2511. },
  2512. {
  2513. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n\n出水COD:当前值为36.10mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.26mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为502.88mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.13%,管控值为80%。\n池2污泥沉降比:当前值为59.56%,管控值为80%。\n池1污泥体积指数:当前值为133.74mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.32mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2514. "conversations": [
  2515. {
  2516. "from": "human",
  2517. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  2518. },
  2519. {
  2520. "from": "gpt",
  2521. "value": "正常"
  2522. },
  2523. {
  2524. "from": "human",
  2525. "value": "出水COD是否连续两次超标?"
  2526. },
  2527. {
  2528. "from": "gpt",
  2529. "value": "存在"
  2530. },
  2531. {
  2532. "from": "human",
  2533. "value": "状态:基本确认出水COD超标了\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  2534. }
  2535. ]
  2536. },
  2537. {
  2538. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.27mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.83mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为503.56mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.57%,管控值为80%。\n池2污泥沉降比:当前值为59.24%,管控值为80%。\n池1污泥体积指数:当前值为134.29mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.89mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2539. "conversations": [
  2540. {
  2541. "from": "human",
  2542. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  2543. },
  2544. {
  2545. "from": "gpt",
  2546. "value": "正常"
  2547. },
  2548. {
  2549. "from": "human",
  2550. "value": "出水COD是否连续两次超标?"
  2551. },
  2552. {
  2553. "from": "gpt",
  2554. "value": "不存在"
  2555. },
  2556. {
  2557. "from": "human",
  2558. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  2559. },
  2560. {
  2561. "from": "gpt",
  2562. "value": "超标"
  2563. },
  2564. {
  2565. "from": "human",
  2566. "value": "状态:人工化验比对,出水COD超标了。\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  2567. }
  2568. ]
  2569. },
  2570. {
  2571. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.19mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.29mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为500.45mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.38%,管控值为80%。\n池2污泥沉降比:当前值为60.19%,管控值为80%。\n池1污泥体积指数:当前值为135.46mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.18mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2572. "conversations": [
  2573. {
  2574. "from": "human",
  2575. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  2576. },
  2577. {
  2578. "from": "gpt",
  2579. "value": "正常"
  2580. },
  2581. {
  2582. "from": "human",
  2583. "value": "出水COD是否连续两次超标?"
  2584. },
  2585. {
  2586. "from": "gpt",
  2587. "value": "不存在"
  2588. },
  2589. {
  2590. "from": "human",
  2591. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  2592. },
  2593. {
  2594. "from": "gpt",
  2595. "value": "不超标"
  2596. },
  2597. {
  2598. "from": "human",
  2599. "value": "状态:人工化验出水COD不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
  2600. }
  2601. ]
  2602. },
  2603. {
  2604. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为0.04mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.42mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为502.84mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.34%,管控值为80%。\n池2污泥沉降比:当前值为60.88%,管控值为80%。\n池1污泥体积指数:当前值为136.65mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.05mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2605. "conversations": [
  2606. {
  2607. "from": "human",
  2608. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  2609. },
  2610. {
  2611. "from": "gpt",
  2612. "value": "不正常"
  2613. },
  2614. {
  2615. "from": "human",
  2616. "value": "状态:仪表不正常\n解决方案:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
  2617. }
  2618. ]
  2619. },
  2620. {
  2621. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.15mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.49mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为501.52mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.40%,管控值为80%。\n池2污泥沉降比:当前值为60.72%,管控值为80%。\n池1污泥体积指数:当前值为134.33mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.93mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2622. "conversations": [
  2623. {
  2624. "from": "human",
  2625. "value": "进水COD高于设计值?"
  2626. },
  2627. {
  2628. "from": "gpt",
  2629. "value": "低于设计值"
  2630. },
  2631. {
  2632. "from": "human",
  2633. "value": "进水总量与设计值的比较是?"
  2634. },
  2635. {
  2636. "from": "gpt",
  2637. "value": "小于设计值"
  2638. },
  2639. {
  2640. "from": "human",
  2641. "value": ""
  2642. }
  2643. ]
  2644. },
  2645. {
  2646. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.74mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.92mg/L,设计值为630mg/L。\n进水水温:当前值是11.53℃。\n进水TDS:当前值为502.42mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.10%,管控值为80%。\n池2污泥沉降比:当前值为59.84%,管控值为80%。\n池1污泥体积指数:当前值为135.89mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.40mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2647. "conversations": [
  2648. {
  2649. "from": "human",
  2650. "value": "进水COD高于设计值?"
  2651. },
  2652. {
  2653. "from": "gpt",
  2654. "value": "低于设计值"
  2655. },
  2656. {
  2657. "from": "human",
  2658. "value": "进水总量与设计值的比较是?"
  2659. },
  2660. {
  2661. "from": "gpt",
  2662. "value": "大于但未超过110%"
  2663. },
  2664. {
  2665. "from": "human",
  2666. "value": "状态:进水COD未超设计值,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  2667. }
  2668. ]
  2669. },
  2670. {
  2671. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.70mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.48mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为502.82mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.30%,管控值为80%。\n池2污泥沉降比:当前值为60.48%,管控值为80%。\n池1污泥体积指数:当前值为134.06mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.88mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2672. "conversations": [
  2673. {
  2674. "from": "human",
  2675. "value": "进水COD高于设计值?"
  2676. },
  2677. {
  2678. "from": "gpt",
  2679. "value": "低于设计值"
  2680. },
  2681. {
  2682. "from": "human",
  2683. "value": "进水总量与设计值的比较是?"
  2684. },
  2685. {
  2686. "from": "gpt",
  2687. "value": "超过110%"
  2688. },
  2689. {
  2690. "from": "human",
  2691. "value": "状态:进水COD未超设计值,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  2692. }
  2693. ]
  2694. },
  2695. {
  2696. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.46mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为650.77mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为501.56mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.76%,管控值为80%。\n池2污泥沉降比:当前值为59.02%,管控值为80%。\n池1污泥体积指数:当前值为133.62mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.45mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2697. "conversations": [
  2698. {
  2699. "from": "human",
  2700. "value": "进水COD高于设计值?"
  2701. },
  2702. {
  2703. "from": "gpt",
  2704. "value": "高于设计值但是低于110%"
  2705. },
  2706. {
  2707. "from": "human",
  2708. "value": "进水总量与设计值的比较是?"
  2709. },
  2710. {
  2711. "from": "gpt",
  2712. "value": "小于设计值"
  2713. },
  2714. {
  2715. "from": "human",
  2716. "value": ""
  2717. }
  2718. ]
  2719. },
  2720. {
  2721. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.35mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为651.65mg/L,设计值为630mg/L。\n进水水温:当前值是11.54℃。\n进水TDS:当前值为502.02mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.82%,管控值为80%。\n池2污泥沉降比:当前值为59.11%,管控值为80%。\n池1污泥体积指数:当前值为135.21mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.71mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2722. "conversations": [
  2723. {
  2724. "from": "human",
  2725. "value": "进水COD高于设计值?"
  2726. },
  2727. {
  2728. "from": "gpt",
  2729. "value": "高于设计值但是低于110%"
  2730. },
  2731. {
  2732. "from": "human",
  2733. "value": "进水总量与设计值的比较是?"
  2734. },
  2735. {
  2736. "from": "gpt",
  2737. "value": "大于但未超过110%"
  2738. },
  2739. {
  2740. "from": "human",
  2741. "value": "状态:进水COD未超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  2742. }
  2743. ]
  2744. },
  2745. {
  2746. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.79mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为649.91mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为503.27mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.05%,管控值为80%。\n池2污泥沉降比:当前值为60.46%,管控值为80%。\n池1污泥体积指数:当前值为136.59mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.50mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2747. "conversations": [
  2748. {
  2749. "from": "human",
  2750. "value": "进水COD高于设计值?"
  2751. },
  2752. {
  2753. "from": "gpt",
  2754. "value": "高于设计值但是低于110%"
  2755. },
  2756. {
  2757. "from": "human",
  2758. "value": "进水总量与设计值的比较是?"
  2759. },
  2760. {
  2761. "from": "gpt",
  2762. "value": "超过110%"
  2763. },
  2764. {
  2765. "from": "human",
  2766. "value": "状态:进水COD未超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  2767. }
  2768. ]
  2769. },
  2770. {
  2771. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.98mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.68mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为503.01mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.74%,管控值为80%。\n池2污泥沉降比:当前值为59.45%,管控值为80%。\n池1污泥体积指数:当前值为136.71mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.40mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2772. "conversations": [
  2773. {
  2774. "from": "human",
  2775. "value": "进水COD高于设计值?"
  2776. },
  2777. {
  2778. "from": "gpt",
  2779. "value": "高于设计值110%"
  2780. },
  2781. {
  2782. "from": "human",
  2783. "value": "进水总量与设计值的比较是?"
  2784. },
  2785. {
  2786. "from": "gpt",
  2787. "value": "小于设计值"
  2788. },
  2789. {
  2790. "from": "human",
  2791. "value": ""
  2792. }
  2793. ]
  2794. },
  2795. {
  2796. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.04mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.90mg/L,设计值为630mg/L。\n进水水温:当前值是11.50℃。\n进水TDS:当前值为502.57mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.68%,管控值为80%。\n池2污泥沉降比:当前值为59.67%,管控值为80%。\n池1污泥体积指数:当前值为135.99mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.88mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2797. "conversations": [
  2798. {
  2799. "from": "human",
  2800. "value": "进水COD高于设计值?"
  2801. },
  2802. {
  2803. "from": "gpt",
  2804. "value": "高于设计值110%"
  2805. },
  2806. {
  2807. "from": "human",
  2808. "value": "进水总量与设计值的比较是?"
  2809. },
  2810. {
  2811. "from": "gpt",
  2812. "value": "大于但未超过110%"
  2813. },
  2814. {
  2815. "from": "human",
  2816. "value": "状态:进水COD超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  2817. }
  2818. ]
  2819. },
  2820. {
  2821. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.91mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.38mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为500.92mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.81%,管控值为80%。\n池2污泥沉降比:当前值为59.77%,管控值为80%。\n池1污泥体积指数:当前值为133.01mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.21mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2822. "conversations": [
  2823. {
  2824. "from": "human",
  2825. "value": "进水COD高于设计值?"
  2826. },
  2827. {
  2828. "from": "gpt",
  2829. "value": "高于设计值110%"
  2830. },
  2831. {
  2832. "from": "human",
  2833. "value": "进水总量与设计值的比较是?"
  2834. },
  2835. {
  2836. "from": "gpt",
  2837. "value": "超过110%"
  2838. },
  2839. {
  2840. "from": "human",
  2841. "value": "状态:进水COD超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  2842. }
  2843. ]
  2844. },
  2845. {
  2846. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.43mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.46mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为502.98mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.84%,管控值为80%。\n池2污泥沉降比:当前值为59.42%,管控值为80%。\n池1污泥体积指数:当前值为134.69mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.60mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为3.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2847. "conversations": [
  2848. {
  2849. "from": "human",
  2850. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  2851. },
  2852. {
  2853. "from": "gpt",
  2854. "value": "都未低于"
  2855. },
  2856. {
  2857. "from": "human",
  2858. "value": ""
  2859. }
  2860. ]
  2861. },
  2862. {
  2863. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.84mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.11mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为503.47mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.33%,管控值为80%。\n池2污泥沉降比:当前值为59.87%,管控值为80%。\n池1污泥体积指数:当前值为134.68mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.61mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2864. "conversations": [
  2865. {
  2866. "from": "human",
  2867. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  2868. },
  2869. {
  2870. "from": "gpt",
  2871. "value": "至少一个池子有低于"
  2872. },
  2873. {
  2874. "from": "human",
  2875. "value": "状态:好氧池溶解氧偏低\n解决方案:\n1、解决供风量不足导致的生化池DO过低\n首先查看风机状态,尝试提高已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,启动或切换备用风机,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决曝气管路不畅、漏气等导致的生化池DO过低\n(1)定期及时排出曝气管路中的领凝水保障管路通常。(2)水面上漏点直接维修;水面下漏点,具备停进水条件的放空后维修,不具备的则按环保要求完成备案同意后,争取最短时间内恢复,在此期间根据实际情况灵活采取过渡措施予以保障。\n3、供风量充足,解决曝气器破损或脱落等导致的生化池DO过低\n关闭或调小泄漏处阀门,减小气量损失,保障生化池充氧效果。具备停水放空条件,及时维修或更换。在此期间根据实际情况灵活采取过渡措施予以保障。\n4、供风量充足,解决生化池负或液位差异导致生化池气量分配不均导致的DO过低\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
  2876. }
  2877. ]
  2878. },
  2879. {
  2880. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.51mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.00mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为500.53mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.40%,管控值为80%。\n池2污泥沉降比:当前值为60.84%,管控值为80%。\n池1污泥体积指数:当前值为133.71mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.02mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2881. "conversations": [
  2882. {
  2883. "from": "human",
  2884. "value": "进水水温是否小于8℃"
  2885. },
  2886. {
  2887. "from": "gpt",
  2888. "value": "否"
  2889. },
  2890. {
  2891. "from": "human",
  2892. "value": ""
  2893. }
  2894. ]
  2895. },
  2896. {
  2897. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.52mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.97mg/L,设计值为630mg/L。\n\n进水水温:当前值是3.51℃。\n进水TDS:当前值为501.94mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.49%,管控值为80%。\n池2污泥沉降比:当前值为60.83%,管控值为80%。\n池1污泥体积指数:当前值为136.36mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.60mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2898. "conversations": [
  2899. {
  2900. "from": "human",
  2901. "value": "进水水温是否小于8℃"
  2902. },
  2903. {
  2904. "from": "gpt",
  2905. "value": "是"
  2906. },
  2907. {
  2908. "from": "human",
  2909. "value": "状态:进水水温小于8℃\n由于水温低于10℃,聚磷菌在低温时生长速度会减慢,生物除磷速率将会迅速下降,微生物活性下降。\n解决方案:\n1、强化温降数据收集与分析,提前预警管控\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时,加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n(1)适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(COD不超过150mg/L)情况下,也可控制在20~25天。\n(2)合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n(3)及时调控回流比,温降或换季期间,较常规运行阶段要适当提高外回流比,一般不超过150%。内回流比则根据总氮变化灵活调整,内外总回流比不宜超过400%。"
  2910. }
  2911. ]
  2912. },
  2913. {
  2914. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.99mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.80mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为502.88mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.03%,管控值为80%。\n池2污泥沉降比:当前值为59.51%,管控值为80%。\n池1污泥体积指数:当前值为136.09mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.72mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2915. "conversations": [
  2916. {
  2917. "from": "human",
  2918. "value": "进水TDS是否超出管控值?"
  2919. },
  2920. {
  2921. "from": "gpt",
  2922. "value": "未超出"
  2923. },
  2924. {
  2925. "from": "human",
  2926. "value": ""
  2927. }
  2928. ]
  2929. },
  2930. {
  2931. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.11mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.48mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为652.74mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.59%,管控值为80%。\n池2污泥沉降比:当前值为59.64%,管控值为80%。\n池1污泥体积指数:当前值为134.75mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.38mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2932. "conversations": [
  2933. {
  2934. "from": "human",
  2935. "value": "进水TDS是否超出管控值?"
  2936. },
  2937. {
  2938. "from": "gpt",
  2939. "value": "超出"
  2940. },
  2941. {
  2942. "from": "human",
  2943. "value": "状态:进水TDS超过管控值\n解决方案:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争在第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力。\n3、毒性小试实验方案\n将现有生化系统活性污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下开展闷曝小试实验,每 8h 取样 1 次,24h 换水 1 次(换水量为 50%),连续运行 72h,比较不同进水 COD、NH3-N 污染物去除效率,根据实验结果确定:① 探究污水厂进水是否对活性良好的微生物菌群产生延时毒性抑制作用;② 探究生化系统内活性污泥的硝化效能;③探究解决当前生化池硝化抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,化系统COD去除率50%以上且不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,COD去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  2944. }
  2945. ]
  2946. },
  2947. {
  2948. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.35mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.67mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.04mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.37%,管控值为80%。\n池2污泥沉降比:当前值为59.16%,管控值为80%。\n池1污泥体积指数:当前值为136.24mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.79mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2949. "conversations": [
  2950. {
  2951. "from": "human",
  2952. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  2953. },
  2954. {
  2955. "from": "gpt",
  2956. "value": "都未超过"
  2957. },
  2958. {
  2959. "from": "human",
  2960. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  2961. },
  2962. {
  2963. "from": "gpt",
  2964. "value": "否"
  2965. },
  2966. {
  2967. "from": "human",
  2968. "value": ""
  2969. }
  2970. ]
  2971. },
  2972. {
  2973. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.95mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.13mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为500.22mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.16%,管控值为80%。\n池2污泥沉降比:当前值为59.22%,管控值为80%。\n池1污泥体积指数:当前值为133.19mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.88mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2974. "conversations": [
  2975. {
  2976. "from": "human",
  2977. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  2978. },
  2979. {
  2980. "from": "gpt",
  2981. "value": "都未超过"
  2982. },
  2983. {
  2984. "from": "human",
  2985. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  2986. },
  2987. {
  2988. "from": "gpt",
  2989. "value": "是"
  2990. },
  2991. {
  2992. "from": "human",
  2993. "value": "状态:生化池有大量泡沫、浮泥等不正常现象\n由于生化池出现大量泡沫、浮泥等不正常现象,可能是污泥膨胀、老化、解絮等导致微生物活性下降,导致出水带泥。\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  2994. }
  2995. ]
  2996. },
  2997. {
  2998. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.32mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.28mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.16mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.72%,管控值为80%。\n池2污泥沉降比:当前值为90.16%,管控值为80%。\n池1污泥体积指数:当前值为133.88mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.06mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  2999. "conversations": [
  3000. {
  3001. "from": "human",
  3002. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  3003. },
  3004. {
  3005. "from": "gpt",
  3006. "value": "至少一个池子有超过"
  3007. },
  3008. {
  3009. "from": "human",
  3010. "value": "状态:污泥沉降比或污泥体积指数异常\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  3011. }
  3012. ]
  3013. },
  3014. {
  3015. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n\n出水COD:当前值为35.92mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.88mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为503.34mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.67%,管控值为80%。\n池2污泥沉降比:当前值为60.86%,管控值为80%。\n池1污泥体积指数:当前值为133.26mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.54mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3016. "conversations": [
  3017. {
  3018. "from": "human",
  3019. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  3020. },
  3021. {
  3022. "from": "gpt",
  3023. "value": "正常"
  3024. },
  3025. {
  3026. "from": "human",
  3027. "value": "出水COD是否连续两次超标?"
  3028. },
  3029. {
  3030. "from": "gpt",
  3031. "value": "存在"
  3032. },
  3033. {
  3034. "from": "human",
  3035. "value": "状态:基本确认出水COD超标了\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  3036. }
  3037. ]
  3038. },
  3039. {
  3040. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.66mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.99mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为502.56mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.22%,管控值为80%。\n池2污泥沉降比:当前值为59.25%,管控值为80%。\n池1污泥体积指数:当前值为136.57mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.36mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3041. "conversations": [
  3042. {
  3043. "from": "human",
  3044. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  3045. },
  3046. {
  3047. "from": "gpt",
  3048. "value": "正常"
  3049. },
  3050. {
  3051. "from": "human",
  3052. "value": "出水COD是否连续两次超标?"
  3053. },
  3054. {
  3055. "from": "gpt",
  3056. "value": "不存在"
  3057. },
  3058. {
  3059. "from": "human",
  3060. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  3061. },
  3062. {
  3063. "from": "gpt",
  3064. "value": "超标"
  3065. },
  3066. {
  3067. "from": "human",
  3068. "value": "状态:人工化验比对,出水COD超标了。\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  3069. }
  3070. ]
  3071. },
  3072. {
  3073. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.90mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.85mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为500.98mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.23%,管控值为80%。\n池2污泥沉降比:当前值为59.44%,管控值为80%。\n池1污泥体积指数:当前值为136.50mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.41mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3074. "conversations": [
  3075. {
  3076. "from": "human",
  3077. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  3078. },
  3079. {
  3080. "from": "gpt",
  3081. "value": "正常"
  3082. },
  3083. {
  3084. "from": "human",
  3085. "value": "出水COD是否连续两次超标?"
  3086. },
  3087. {
  3088. "from": "gpt",
  3089. "value": "不存在"
  3090. },
  3091. {
  3092. "from": "human",
  3093. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  3094. },
  3095. {
  3096. "from": "gpt",
  3097. "value": "不超标"
  3098. },
  3099. {
  3100. "from": "human",
  3101. "value": "状态:人工化验出水COD不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
  3102. }
  3103. ]
  3104. },
  3105. {
  3106. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为-0.03mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.99mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.15mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.62%,管控值为80%。\n池2污泥沉降比:当前值为59.95%,管控值为80%。\n池1污泥体积指数:当前值为133.06mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.18mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3107. "conversations": [
  3108. {
  3109. "from": "human",
  3110. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  3111. },
  3112. {
  3113. "from": "gpt",
  3114. "value": "不正常"
  3115. },
  3116. {
  3117. "from": "human",
  3118. "value": "状态:仪表不正常\n解决方案:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
  3119. }
  3120. ]
  3121. },
  3122. {
  3123. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.35mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.50mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为503.52mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.86%,管控值为80%。\n池2污泥沉降比:当前值为60.70%,管控值为80%。\n池1污泥体积指数:当前值为136.54mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.88mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3124. "conversations": [
  3125. {
  3126. "from": "human",
  3127. "value": "进水COD高于设计值?"
  3128. },
  3129. {
  3130. "from": "gpt",
  3131. "value": "低于设计值"
  3132. },
  3133. {
  3134. "from": "human",
  3135. "value": "进水总量与设计值的比较是?"
  3136. },
  3137. {
  3138. "from": "gpt",
  3139. "value": "小于设计值"
  3140. },
  3141. {
  3142. "from": "human",
  3143. "value": ""
  3144. }
  3145. ]
  3146. },
  3147. {
  3148. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.74mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.96mg/L,设计值为630mg/L。\n进水水温:当前值是11.52℃。\n进水TDS:当前值为500.97mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.88%,管控值为80%。\n池2污泥沉降比:当前值为60.21%,管控值为80%。\n池1污泥体积指数:当前值为135.02mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.75mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3149. "conversations": [
  3150. {
  3151. "from": "human",
  3152. "value": "进水COD高于设计值?"
  3153. },
  3154. {
  3155. "from": "gpt",
  3156. "value": "低于设计值"
  3157. },
  3158. {
  3159. "from": "human",
  3160. "value": "进水总量与设计值的比较是?"
  3161. },
  3162. {
  3163. "from": "gpt",
  3164. "value": "大于但未超过110%"
  3165. },
  3166. {
  3167. "from": "human",
  3168. "value": "状态:进水COD未超设计值,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  3169. }
  3170. ]
  3171. },
  3172. {
  3173. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.22mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.16mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为501.21mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.50%,管控值为80%。\n池2污泥沉降比:当前值为60.70%,管控值为80%。\n池1污泥体积指数:当前值为133.63mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.84mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3174. "conversations": [
  3175. {
  3176. "from": "human",
  3177. "value": "进水COD高于设计值?"
  3178. },
  3179. {
  3180. "from": "gpt",
  3181. "value": "低于设计值"
  3182. },
  3183. {
  3184. "from": "human",
  3185. "value": "进水总量与设计值的比较是?"
  3186. },
  3187. {
  3188. "from": "gpt",
  3189. "value": "超过110%"
  3190. },
  3191. {
  3192. "from": "human",
  3193. "value": "状态:进水COD未超设计值,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  3194. }
  3195. ]
  3196. },
  3197. {
  3198. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.78mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为648.92mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为500.86mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.73%,管控值为80%。\n池2污泥沉降比:当前值为60.36%,管控值为80%。\n池1污泥体积指数:当前值为134.89mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.92mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3199. "conversations": [
  3200. {
  3201. "from": "human",
  3202. "value": "进水COD高于设计值?"
  3203. },
  3204. {
  3205. "from": "gpt",
  3206. "value": "高于设计值但是低于110%"
  3207. },
  3208. {
  3209. "from": "human",
  3210. "value": "进水总量与设计值的比较是?"
  3211. },
  3212. {
  3213. "from": "gpt",
  3214. "value": "小于设计值"
  3215. },
  3216. {
  3217. "from": "human",
  3218. "value": ""
  3219. }
  3220. ]
  3221. },
  3222. {
  3223. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.59mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为649.24mg/L,设计值为630mg/L。\n进水水温:当前值是11.52℃。\n进水TDS:当前值为503.20mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.41%,管控值为80%。\n池2污泥沉降比:当前值为59.16%,管控值为80%。\n池1污泥体积指数:当前值为136.58mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.87mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3224. "conversations": [
  3225. {
  3226. "from": "human",
  3227. "value": "进水COD高于设计值?"
  3228. },
  3229. {
  3230. "from": "gpt",
  3231. "value": "高于设计值但是低于110%"
  3232. },
  3233. {
  3234. "from": "human",
  3235. "value": "进水总量与设计值的比较是?"
  3236. },
  3237. {
  3238. "from": "gpt",
  3239. "value": "大于但未超过110%"
  3240. },
  3241. {
  3242. "from": "human",
  3243. "value": "状态:进水COD未超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  3244. }
  3245. ]
  3246. },
  3247. {
  3248. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.96mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为648.84mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为500.76mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.68%,管控值为80%。\n池2污泥沉降比:当前值为60.54%,管控值为80%。\n池1污泥体积指数:当前值为133.54mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.09mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3249. "conversations": [
  3250. {
  3251. "from": "human",
  3252. "value": "进水COD高于设计值?"
  3253. },
  3254. {
  3255. "from": "gpt",
  3256. "value": "高于设计值但是低于110%"
  3257. },
  3258. {
  3259. "from": "human",
  3260. "value": "进水总量与设计值的比较是?"
  3261. },
  3262. {
  3263. "from": "gpt",
  3264. "value": "超过110%"
  3265. },
  3266. {
  3267. "from": "human",
  3268. "value": "状态:进水COD未超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  3269. }
  3270. ]
  3271. },
  3272. {
  3273. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.28mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.10mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.66mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.27%,管控值为80%。\n池2污泥沉降比:当前值为59.19%,管控值为80%。\n池1污泥体积指数:当前值为134.74mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.16mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3274. "conversations": [
  3275. {
  3276. "from": "human",
  3277. "value": "进水COD高于设计值?"
  3278. },
  3279. {
  3280. "from": "gpt",
  3281. "value": "高于设计值110%"
  3282. },
  3283. {
  3284. "from": "human",
  3285. "value": "进水总量与设计值的比较是?"
  3286. },
  3287. {
  3288. "from": "gpt",
  3289. "value": "小于设计值"
  3290. },
  3291. {
  3292. "from": "human",
  3293. "value": ""
  3294. }
  3295. ]
  3296. },
  3297. {
  3298. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.34mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.30mg/L,设计值为630mg/L。\n进水水温:当前值是11.53℃。\n进水TDS:当前值为502.32mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.37%,管控值为80%。\n池2污泥沉降比:当前值为60.85%,管控值为80%。\n池1污泥体积指数:当前值为135.14mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.36mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3299. "conversations": [
  3300. {
  3301. "from": "human",
  3302. "value": "进水COD高于设计值?"
  3303. },
  3304. {
  3305. "from": "gpt",
  3306. "value": "高于设计值110%"
  3307. },
  3308. {
  3309. "from": "human",
  3310. "value": "进水总量与设计值的比较是?"
  3311. },
  3312. {
  3313. "from": "gpt",
  3314. "value": "大于但未超过110%"
  3315. },
  3316. {
  3317. "from": "human",
  3318. "value": "状态:进水COD超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  3319. }
  3320. ]
  3321. },
  3322. {
  3323. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.43mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.89mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为500.39mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.67%,管控值为80%。\n池2污泥沉降比:当前值为59.72%,管控值为80%。\n池1污泥体积指数:当前值为136.36mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.41mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3324. "conversations": [
  3325. {
  3326. "from": "human",
  3327. "value": "进水COD高于设计值?"
  3328. },
  3329. {
  3330. "from": "gpt",
  3331. "value": "高于设计值110%"
  3332. },
  3333. {
  3334. "from": "human",
  3335. "value": "进水总量与设计值的比较是?"
  3336. },
  3337. {
  3338. "from": "gpt",
  3339. "value": "超过110%"
  3340. },
  3341. {
  3342. "from": "human",
  3343. "value": "状态:进水COD超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  3344. }
  3345. ]
  3346. },
  3347. {
  3348. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.75mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.60mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为500.53mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.58%,管控值为80%。\n池2污泥沉降比:当前值为59.28%,管控值为80%。\n池1污泥体积指数:当前值为136.39mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.28mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为3.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3349. "conversations": [
  3350. {
  3351. "from": "human",
  3352. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  3353. },
  3354. {
  3355. "from": "gpt",
  3356. "value": "都未低于"
  3357. },
  3358. {
  3359. "from": "human",
  3360. "value": ""
  3361. }
  3362. ]
  3363. },
  3364. {
  3365. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.06mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.30mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为500.57mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.32%,管控值为80%。\n池2污泥沉降比:当前值为60.22%,管控值为80%。\n池1污泥体积指数:当前值为134.94mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.30mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3366. "conversations": [
  3367. {
  3368. "from": "human",
  3369. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  3370. },
  3371. {
  3372. "from": "gpt",
  3373. "value": "至少一个池子有低于"
  3374. },
  3375. {
  3376. "from": "human",
  3377. "value": "状态:好氧池溶解氧偏低\n解决方案:\n1、解决供风量不足导致的生化池DO过低\n首先查看风机状态,尝试提高已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,启动或切换备用风机,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决曝气管路不畅、漏气等导致的生化池DO过低\n(1)定期及时排出曝气管路中的领凝水保障管路通常。(2)水面上漏点直接维修;水面下漏点,具备停进水条件的放空后维修,不具备的则按环保要求完成备案同意后,争取最短时间内恢复,在此期间根据实际情况灵活采取过渡措施予以保障。\n3、供风量充足,解决曝气器破损或脱落等导致的生化池DO过低\n关闭或调小泄漏处阀门,减小气量损失,保障生化池充氧效果。具备停水放空条件,及时维修或更换。在此期间根据实际情况灵活采取过渡措施予以保障。\n4、供风量充足,解决生化池负或液位差异导致生化池气量分配不均导致的DO过低\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
  3378. }
  3379. ]
  3380. },
  3381. {
  3382. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.72mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.00mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为500.18mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.63%,管控值为80%。\n池2污泥沉降比:当前值为60.42%,管控值为80%。\n池1污泥体积指数:当前值为134.28mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.32mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3383. "conversations": [
  3384. {
  3385. "from": "human",
  3386. "value": "进水水温是否小于8℃"
  3387. },
  3388. {
  3389. "from": "gpt",
  3390. "value": "否"
  3391. },
  3392. {
  3393. "from": "human",
  3394. "value": ""
  3395. }
  3396. ]
  3397. },
  3398. {
  3399. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.78mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.55mg/L,设计值为630mg/L。\n\n进水水温:当前值是3.54℃。\n进水TDS:当前值为502.09mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.58%,管控值为80%。\n池2污泥沉降比:当前值为60.37%,管控值为80%。\n池1污泥体积指数:当前值为134.48mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.79mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3400. "conversations": [
  3401. {
  3402. "from": "human",
  3403. "value": "进水水温是否小于8℃"
  3404. },
  3405. {
  3406. "from": "gpt",
  3407. "value": "是"
  3408. },
  3409. {
  3410. "from": "human",
  3411. "value": "状态:进水水温小于8℃\n由于水温低于10℃,聚磷菌在低温时生长速度会减慢,生物除磷速率将会迅速下降,微生物活性下降。\n解决方案:\n1、强化温降数据收集与分析,提前预警管控\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时,加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n(1)适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(COD不超过150mg/L)情况下,也可控制在20~25天。\n(2)合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n(3)及时调控回流比,温降或换季期间,较常规运行阶段要适当提高外回流比,一般不超过150%。内回流比则根据总氮变化灵活调整,内外总回流比不宜超过400%。"
  3412. }
  3413. ]
  3414. },
  3415. {
  3416. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.65mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.38mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为501.29mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.96%,管控值为80%。\n池2污泥沉降比:当前值为59.57%,管控值为80%。\n池1污泥体积指数:当前值为134.94mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.68mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3417. "conversations": [
  3418. {
  3419. "from": "human",
  3420. "value": "进水TDS是否超出管控值?"
  3421. },
  3422. {
  3423. "from": "gpt",
  3424. "value": "未超出"
  3425. },
  3426. {
  3427. "from": "human",
  3428. "value": ""
  3429. }
  3430. ]
  3431. },
  3432. {
  3433. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.21mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.71mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为650.24mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.04%,管控值为80%。\n池2污泥沉降比:当前值为60.04%,管控值为80%。\n池1污泥体积指数:当前值为135.40mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.21mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3434. "conversations": [
  3435. {
  3436. "from": "human",
  3437. "value": "进水TDS是否超出管控值?"
  3438. },
  3439. {
  3440. "from": "gpt",
  3441. "value": "超出"
  3442. },
  3443. {
  3444. "from": "human",
  3445. "value": "状态:进水TDS超过管控值\n解决方案:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争在第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力。\n3、毒性小试实验方案\n将现有生化系统活性污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下开展闷曝小试实验,每 8h 取样 1 次,24h 换水 1 次(换水量为 50%),连续运行 72h,比较不同进水 COD、NH3-N 污染物去除效率,根据实验结果确定:① 探究污水厂进水是否对活性良好的微生物菌群产生延时毒性抑制作用;② 探究生化系统内活性污泥的硝化效能;③探究解决当前生化池硝化抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,化系统COD去除率50%以上且不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,COD去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  3446. }
  3447. ]
  3448. },
  3449. {
  3450. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.56mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.01mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为502.85mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.47%,管控值为80%。\n池2污泥沉降比:当前值为60.31%,管控值为80%。\n池1污泥体积指数:当前值为135.87mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.67mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3451. "conversations": [
  3452. {
  3453. "from": "human",
  3454. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  3455. },
  3456. {
  3457. "from": "gpt",
  3458. "value": "都未超过"
  3459. },
  3460. {
  3461. "from": "human",
  3462. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  3463. },
  3464. {
  3465. "from": "gpt",
  3466. "value": "否"
  3467. },
  3468. {
  3469. "from": "human",
  3470. "value": ""
  3471. }
  3472. ]
  3473. },
  3474. {
  3475. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.36mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.71mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.61mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.50%,管控值为80%。\n池2污泥沉降比:当前值为60.95%,管控值为80%。\n池1污泥体积指数:当前值为135.18mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.84mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3476. "conversations": [
  3477. {
  3478. "from": "human",
  3479. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  3480. },
  3481. {
  3482. "from": "gpt",
  3483. "value": "都未超过"
  3484. },
  3485. {
  3486. "from": "human",
  3487. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  3488. },
  3489. {
  3490. "from": "gpt",
  3491. "value": "是"
  3492. },
  3493. {
  3494. "from": "human",
  3495. "value": "状态:生化池有大量泡沫、浮泥等不正常现象\n由于生化池出现大量泡沫、浮泥等不正常现象,可能是污泥膨胀、老化、解絮等导致微生物活性下降,导致出水带泥。\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  3496. }
  3497. ]
  3498. },
  3499. {
  3500. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.93mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.29mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为501.24mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.27%,管控值为80%。\n池2污泥沉降比:当前值为90.84%,管控值为80%。\n池1污泥体积指数:当前值为136.76mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.19mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3501. "conversations": [
  3502. {
  3503. "from": "human",
  3504. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  3505. },
  3506. {
  3507. "from": "gpt",
  3508. "value": "至少一个池子有超过"
  3509. },
  3510. {
  3511. "from": "human",
  3512. "value": "状态:污泥沉降比或污泥体积指数异常\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  3513. }
  3514. ]
  3515. },
  3516. {
  3517. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n\n出水COD:当前值为35.23mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.97mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为503.26mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.29%,管控值为80%。\n池2污泥沉降比:当前值为60.42%,管控值为80%。\n池1污泥体积指数:当前值为133.94mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.28mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3518. "conversations": [
  3519. {
  3520. "from": "human",
  3521. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  3522. },
  3523. {
  3524. "from": "gpt",
  3525. "value": "正常"
  3526. },
  3527. {
  3528. "from": "human",
  3529. "value": "出水COD是否连续两次超标?"
  3530. },
  3531. {
  3532. "from": "gpt",
  3533. "value": "存在"
  3534. },
  3535. {
  3536. "from": "human",
  3537. "value": "状态:基本确认出水COD超标了\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  3538. }
  3539. ]
  3540. },
  3541. {
  3542. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.26mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.77mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为503.83mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.81%,管控值为80%。\n池2污泥沉降比:当前值为59.39%,管控值为80%。\n池1污泥体积指数:当前值为134.84mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.48mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3543. "conversations": [
  3544. {
  3545. "from": "human",
  3546. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  3547. },
  3548. {
  3549. "from": "gpt",
  3550. "value": "正常"
  3551. },
  3552. {
  3553. "from": "human",
  3554. "value": "出水COD是否连续两次超标?"
  3555. },
  3556. {
  3557. "from": "gpt",
  3558. "value": "不存在"
  3559. },
  3560. {
  3561. "from": "human",
  3562. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  3563. },
  3564. {
  3565. "from": "gpt",
  3566. "value": "超标"
  3567. },
  3568. {
  3569. "from": "human",
  3570. "value": "状态:人工化验比对,出水COD超标了。\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  3571. }
  3572. ]
  3573. },
  3574. {
  3575. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.22mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.75mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为502.08mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.46%,管控值为80%。\n池2污泥沉降比:当前值为60.55%,管控值为80%。\n池1污泥体积指数:当前值为135.12mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.97mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3576. "conversations": [
  3577. {
  3578. "from": "human",
  3579. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  3580. },
  3581. {
  3582. "from": "gpt",
  3583. "value": "正常"
  3584. },
  3585. {
  3586. "from": "human",
  3587. "value": "出水COD是否连续两次超标?"
  3588. },
  3589. {
  3590. "from": "gpt",
  3591. "value": "不存在"
  3592. },
  3593. {
  3594. "from": "human",
  3595. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  3596. },
  3597. {
  3598. "from": "gpt",
  3599. "value": "不超标"
  3600. },
  3601. {
  3602. "from": "human",
  3603. "value": "状态:人工化验出水COD不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
  3604. }
  3605. ]
  3606. },
  3607. {
  3608. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为-0.04mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.44mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.18mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.02%,管控值为80%。\n池2污泥沉降比:当前值为59.35%,管控值为80%。\n池1污泥体积指数:当前值为136.72mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.27mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3609. "conversations": [
  3610. {
  3611. "from": "human",
  3612. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  3613. },
  3614. {
  3615. "from": "gpt",
  3616. "value": "不正常"
  3617. },
  3618. {
  3619. "from": "human",
  3620. "value": "状态:仪表不正常\n解决方案:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
  3621. }
  3622. ]
  3623. },
  3624. {
  3625. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.69mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.10mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为503.27mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.11%,管控值为80%。\n池2污泥沉降比:当前值为60.26%,管控值为80%。\n池1污泥体积指数:当前值为136.16mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.30mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3626. "conversations": [
  3627. {
  3628. "from": "human",
  3629. "value": "进水COD高于设计值?"
  3630. },
  3631. {
  3632. "from": "gpt",
  3633. "value": "低于设计值"
  3634. },
  3635. {
  3636. "from": "human",
  3637. "value": "进水总量与设计值的比较是?"
  3638. },
  3639. {
  3640. "from": "gpt",
  3641. "value": "小于设计值"
  3642. },
  3643. {
  3644. "from": "human",
  3645. "value": ""
  3646. }
  3647. ]
  3648. },
  3649. {
  3650. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.01mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.44mg/L,设计值为630mg/L。\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.42mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.59%,管控值为80%。\n池2污泥沉降比:当前值为60.09%,管控值为80%。\n池1污泥体积指数:当前值为136.05mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.91mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3651. "conversations": [
  3652. {
  3653. "from": "human",
  3654. "value": "进水COD高于设计值?"
  3655. },
  3656. {
  3657. "from": "gpt",
  3658. "value": "低于设计值"
  3659. },
  3660. {
  3661. "from": "human",
  3662. "value": "进水总量与设计值的比较是?"
  3663. },
  3664. {
  3665. "from": "gpt",
  3666. "value": "大于但未超过110%"
  3667. },
  3668. {
  3669. "from": "human",
  3670. "value": "状态:进水COD未超设计值,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  3671. }
  3672. ]
  3673. },
  3674. {
  3675. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.55mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.60mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为501.79mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.19%,管控值为80%。\n池2污泥沉降比:当前值为59.68%,管控值为80%。\n池1污泥体积指数:当前值为136.46mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.01mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3676. "conversations": [
  3677. {
  3678. "from": "human",
  3679. "value": "进水COD高于设计值?"
  3680. },
  3681. {
  3682. "from": "gpt",
  3683. "value": "低于设计值"
  3684. },
  3685. {
  3686. "from": "human",
  3687. "value": "进水总量与设计值的比较是?"
  3688. },
  3689. {
  3690. "from": "gpt",
  3691. "value": "超过110%"
  3692. },
  3693. {
  3694. "from": "human",
  3695. "value": "状态:进水COD未超设计值,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  3696. }
  3697. ]
  3698. },
  3699. {
  3700. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.98mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为650.23mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为500.46mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.72%,管控值为80%。\n池2污泥沉降比:当前值为59.73%,管控值为80%。\n池1污泥体积指数:当前值为135.70mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.13mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3701. "conversations": [
  3702. {
  3703. "from": "human",
  3704. "value": "进水COD高于设计值?"
  3705. },
  3706. {
  3707. "from": "gpt",
  3708. "value": "高于设计值但是低于110%"
  3709. },
  3710. {
  3711. "from": "human",
  3712. "value": "进水总量与设计值的比较是?"
  3713. },
  3714. {
  3715. "from": "gpt",
  3716. "value": "小于设计值"
  3717. },
  3718. {
  3719. "from": "human",
  3720. "value": ""
  3721. }
  3722. ]
  3723. },
  3724. {
  3725. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.39mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为651.17mg/L,设计值为630mg/L。\n进水水温:当前值是11.54℃。\n进水TDS:当前值为503.18mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.39%,管控值为80%。\n池2污泥沉降比:当前值为59.72%,管控值为80%。\n池1污泥体积指数:当前值为135.77mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.64mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3726. "conversations": [
  3727. {
  3728. "from": "human",
  3729. "value": "进水COD高于设计值?"
  3730. },
  3731. {
  3732. "from": "gpt",
  3733. "value": "高于设计值但是低于110%"
  3734. },
  3735. {
  3736. "from": "human",
  3737. "value": "进水总量与设计值的比较是?"
  3738. },
  3739. {
  3740. "from": "gpt",
  3741. "value": "大于但未超过110%"
  3742. },
  3743. {
  3744. "from": "human",
  3745. "value": "状态:进水COD未超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  3746. }
  3747. ]
  3748. },
  3749. {
  3750. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.43mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为651.58mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为503.50mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.07%,管控值为80%。\n池2污泥沉降比:当前值为60.48%,管控值为80%。\n池1污泥体积指数:当前值为134.23mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.24mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3751. "conversations": [
  3752. {
  3753. "from": "human",
  3754. "value": "进水COD高于设计值?"
  3755. },
  3756. {
  3757. "from": "gpt",
  3758. "value": "高于设计值但是低于110%"
  3759. },
  3760. {
  3761. "from": "human",
  3762. "value": "进水总量与设计值的比较是?"
  3763. },
  3764. {
  3765. "from": "gpt",
  3766. "value": "超过110%"
  3767. },
  3768. {
  3769. "from": "human",
  3770. "value": "状态:进水COD未超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  3771. }
  3772. ]
  3773. },
  3774. {
  3775. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.79mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.09mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为500.45mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.98%,管控值为80%。\n池2污泥沉降比:当前值为59.28%,管控值为80%。\n池1污泥体积指数:当前值为134.49mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.67mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3776. "conversations": [
  3777. {
  3778. "from": "human",
  3779. "value": "进水COD高于设计值?"
  3780. },
  3781. {
  3782. "from": "gpt",
  3783. "value": "高于设计值110%"
  3784. },
  3785. {
  3786. "from": "human",
  3787. "value": "进水总量与设计值的比较是?"
  3788. },
  3789. {
  3790. "from": "gpt",
  3791. "value": "小于设计值"
  3792. },
  3793. {
  3794. "from": "human",
  3795. "value": ""
  3796. }
  3797. ]
  3798. },
  3799. {
  3800. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.95mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.95mg/L,设计值为630mg/L。\n进水水温:当前值是11.53℃。\n进水TDS:当前值为503.56mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.24%,管控值为80%。\n池2污泥沉降比:当前值为60.87%,管控值为80%。\n池1污泥体积指数:当前值为135.14mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.66mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3801. "conversations": [
  3802. {
  3803. "from": "human",
  3804. "value": "进水COD高于设计值?"
  3805. },
  3806. {
  3807. "from": "gpt",
  3808. "value": "高于设计值110%"
  3809. },
  3810. {
  3811. "from": "human",
  3812. "value": "进水总量与设计值的比较是?"
  3813. },
  3814. {
  3815. "from": "gpt",
  3816. "value": "大于但未超过110%"
  3817. },
  3818. {
  3819. "from": "human",
  3820. "value": "状态:进水COD超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  3821. }
  3822. ]
  3823. },
  3824. {
  3825. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.27mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.99mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为503.69mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.02%,管控值为80%。\n池2污泥沉降比:当前值为60.08%,管控值为80%。\n池1污泥体积指数:当前值为136.32mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.40mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3826. "conversations": [
  3827. {
  3828. "from": "human",
  3829. "value": "进水COD高于设计值?"
  3830. },
  3831. {
  3832. "from": "gpt",
  3833. "value": "高于设计值110%"
  3834. },
  3835. {
  3836. "from": "human",
  3837. "value": "进水总量与设计值的比较是?"
  3838. },
  3839. {
  3840. "from": "gpt",
  3841. "value": "超过110%"
  3842. },
  3843. {
  3844. "from": "human",
  3845. "value": "状态:进水COD超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  3846. }
  3847. ]
  3848. },
  3849. {
  3850. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.37mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.77mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为502.13mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.21%,管控值为80%。\n池2污泥沉降比:当前值为59.49%,管控值为80%。\n池1污泥体积指数:当前值为133.06mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.91mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为3.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3851. "conversations": [
  3852. {
  3853. "from": "human",
  3854. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  3855. },
  3856. {
  3857. "from": "gpt",
  3858. "value": "都未低于"
  3859. },
  3860. {
  3861. "from": "human",
  3862. "value": ""
  3863. }
  3864. ]
  3865. },
  3866. {
  3867. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.89mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.67mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为500.56mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.00%,管控值为80%。\n池2污泥沉降比:当前值为59.57%,管控值为80%。\n池1污泥体积指数:当前值为133.64mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.53mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3868. "conversations": [
  3869. {
  3870. "from": "human",
  3871. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  3872. },
  3873. {
  3874. "from": "gpt",
  3875. "value": "至少一个池子有低于"
  3876. },
  3877. {
  3878. "from": "human",
  3879. "value": "状态:好氧池溶解氧偏低\n解决方案:\n1、解决供风量不足导致的生化池DO过低\n首先查看风机状态,尝试提高已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,启动或切换备用风机,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决曝气管路不畅、漏气等导致的生化池DO过低\n(1)定期及时排出曝气管路中的领凝水保障管路通常。(2)水面上漏点直接维修;水面下漏点,具备停进水条件的放空后维修,不具备的则按环保要求完成备案同意后,争取最短时间内恢复,在此期间根据实际情况灵活采取过渡措施予以保障。\n3、供风量充足,解决曝气器破损或脱落等导致的生化池DO过低\n关闭或调小泄漏处阀门,减小气量损失,保障生化池充氧效果。具备停水放空条件,及时维修或更换。在此期间根据实际情况灵活采取过渡措施予以保障。\n4、供风量充足,解决生化池负或液位差异导致生化池气量分配不均导致的DO过低\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
  3880. }
  3881. ]
  3882. },
  3883. {
  3884. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.27mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.85mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为500.88mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.90%,管控值为80%。\n池2污泥沉降比:当前值为60.34%,管控值为80%。\n池1污泥体积指数:当前值为136.13mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.03mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3885. "conversations": [
  3886. {
  3887. "from": "human",
  3888. "value": "进水水温是否小于8℃"
  3889. },
  3890. {
  3891. "from": "gpt",
  3892. "value": "否"
  3893. },
  3894. {
  3895. "from": "human",
  3896. "value": ""
  3897. }
  3898. ]
  3899. },
  3900. {
  3901. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.21mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.54mg/L,设计值为630mg/L。\n\n进水水温:当前值是3.53℃。\n进水TDS:当前值为502.48mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.71%,管控值为80%。\n池2污泥沉降比:当前值为59.90%,管控值为80%。\n池1污泥体积指数:当前值为134.21mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.34mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3902. "conversations": [
  3903. {
  3904. "from": "human",
  3905. "value": "进水水温是否小于8℃"
  3906. },
  3907. {
  3908. "from": "gpt",
  3909. "value": "是"
  3910. },
  3911. {
  3912. "from": "human",
  3913. "value": "状态:进水水温小于8℃\n由于水温低于10℃,聚磷菌在低温时生长速度会减慢,生物除磷速率将会迅速下降,微生物活性下降。\n解决方案:\n1、强化温降数据收集与分析,提前预警管控\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时,加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n(1)适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(COD不超过150mg/L)情况下,也可控制在20~25天。\n(2)合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n(3)及时调控回流比,温降或换季期间,较常规运行阶段要适当提高外回流比,一般不超过150%。内回流比则根据总氮变化灵活调整,内外总回流比不宜超过400%。"
  3914. }
  3915. ]
  3916. },
  3917. {
  3918. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.39mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.39mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为500.54mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.55%,管控值为80%。\n池2污泥沉降比:当前值为59.74%,管控值为80%。\n池1污泥体积指数:当前值为135.76mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.27mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3919. "conversations": [
  3920. {
  3921. "from": "human",
  3922. "value": "进水TDS是否超出管控值?"
  3923. },
  3924. {
  3925. "from": "gpt",
  3926. "value": "未超出"
  3927. },
  3928. {
  3929. "from": "human",
  3930. "value": ""
  3931. }
  3932. ]
  3933. },
  3934. {
  3935. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.82mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.77mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为651.19mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.14%,管控值为80%。\n池2污泥沉降比:当前值为60.28%,管控值为80%。\n池1污泥体积指数:当前值为133.34mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.61mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3936. "conversations": [
  3937. {
  3938. "from": "human",
  3939. "value": "进水TDS是否超出管控值?"
  3940. },
  3941. {
  3942. "from": "gpt",
  3943. "value": "超出"
  3944. },
  3945. {
  3946. "from": "human",
  3947. "value": "状态:进水TDS超过管控值\n解决方案:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争在第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力。\n3、毒性小试实验方案\n将现有生化系统活性污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下开展闷曝小试实验,每 8h 取样 1 次,24h 换水 1 次(换水量为 50%),连续运行 72h,比较不同进水 COD、NH3-N 污染物去除效率,根据实验结果确定:① 探究污水厂进水是否对活性良好的微生物菌群产生延时毒性抑制作用;② 探究生化系统内活性污泥的硝化效能;③探究解决当前生化池硝化抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,化系统COD去除率50%以上且不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,COD去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  3948. }
  3949. ]
  3950. },
  3951. {
  3952. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.37mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.83mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为503.46mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.37%,管控值为80%。\n池2污泥沉降比:当前值为60.95%,管控值为80%。\n池1污泥体积指数:当前值为135.23mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.54mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3953. "conversations": [
  3954. {
  3955. "from": "human",
  3956. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  3957. },
  3958. {
  3959. "from": "gpt",
  3960. "value": "都未超过"
  3961. },
  3962. {
  3963. "from": "human",
  3964. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  3965. },
  3966. {
  3967. "from": "gpt",
  3968. "value": "否"
  3969. },
  3970. {
  3971. "from": "human",
  3972. "value": ""
  3973. }
  3974. ]
  3975. },
  3976. {
  3977. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.05mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.96mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为501.87mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.40%,管控值为80%。\n池2污泥沉降比:当前值为59.17%,管控值为80%。\n池1污泥体积指数:当前值为134.75mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.74mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  3978. "conversations": [
  3979. {
  3980. "from": "human",
  3981. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  3982. },
  3983. {
  3984. "from": "gpt",
  3985. "value": "都未超过"
  3986. },
  3987. {
  3988. "from": "human",
  3989. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  3990. },
  3991. {
  3992. "from": "gpt",
  3993. "value": "是"
  3994. },
  3995. {
  3996. "from": "human",
  3997. "value": "状态:生化池有大量泡沫、浮泥等不正常现象\n由于生化池出现大量泡沫、浮泥等不正常现象,可能是污泥膨胀、老化、解絮等导致微生物活性下降,导致出水带泥。\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  3998. }
  3999. ]
  4000. },
  4001. {
  4002. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.54mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.99mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为502.83mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.08%,管控值为80%。\n池2污泥沉降比:当前值为89.64%,管控值为80%。\n池1污泥体积指数:当前值为133.90mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.92mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4003. "conversations": [
  4004. {
  4005. "from": "human",
  4006. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  4007. },
  4008. {
  4009. "from": "gpt",
  4010. "value": "至少一个池子有超过"
  4011. },
  4012. {
  4013. "from": "human",
  4014. "value": "状态:污泥沉降比或污泥体积指数异常\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  4015. }
  4016. ]
  4017. },
  4018. {
  4019. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n\n出水COD:当前值为35.08mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.31mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为500.41mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.56%,管控值为80%。\n池2污泥沉降比:当前值为60.39%,管控值为80%。\n池1污泥体积指数:当前值为134.48mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.95mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4020. "conversations": [
  4021. {
  4022. "from": "human",
  4023. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  4024. },
  4025. {
  4026. "from": "gpt",
  4027. "value": "正常"
  4028. },
  4029. {
  4030. "from": "human",
  4031. "value": "出水COD是否连续两次超标?"
  4032. },
  4033. {
  4034. "from": "gpt",
  4035. "value": "存在"
  4036. },
  4037. {
  4038. "from": "human",
  4039. "value": "状态:基本确认出水COD超标了\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  4040. }
  4041. ]
  4042. },
  4043. {
  4044. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.68mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.71mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为502.24mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.67%,管控值为80%。\n池2污泥沉降比:当前值为59.11%,管控值为80%。\n池1污泥体积指数:当前值为135.78mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.96mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4045. "conversations": [
  4046. {
  4047. "from": "human",
  4048. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  4049. },
  4050. {
  4051. "from": "gpt",
  4052. "value": "正常"
  4053. },
  4054. {
  4055. "from": "human",
  4056. "value": "出水COD是否连续两次超标?"
  4057. },
  4058. {
  4059. "from": "gpt",
  4060. "value": "不存在"
  4061. },
  4062. {
  4063. "from": "human",
  4064. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  4065. },
  4066. {
  4067. "from": "gpt",
  4068. "value": "超标"
  4069. },
  4070. {
  4071. "from": "human",
  4072. "value": "状态:人工化验比对,出水COD超标了。\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  4073. }
  4074. ]
  4075. },
  4076. {
  4077. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.74mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.66mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为503.55mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.20%,管控值为80%。\n池2污泥沉降比:当前值为60.95%,管控值为80%。\n池1污泥体积指数:当前值为133.32mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.60mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4078. "conversations": [
  4079. {
  4080. "from": "human",
  4081. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  4082. },
  4083. {
  4084. "from": "gpt",
  4085. "value": "正常"
  4086. },
  4087. {
  4088. "from": "human",
  4089. "value": "出水COD是否连续两次超标?"
  4090. },
  4091. {
  4092. "from": "gpt",
  4093. "value": "不存在"
  4094. },
  4095. {
  4096. "from": "human",
  4097. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  4098. },
  4099. {
  4100. "from": "gpt",
  4101. "value": "不超标"
  4102. },
  4103. {
  4104. "from": "human",
  4105. "value": "状态:人工化验出水COD不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
  4106. }
  4107. ]
  4108. },
  4109. {
  4110. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为-0.03mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.12mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为500.30mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.40%,管控值为80%。\n池2污泥沉降比:当前值为59.08%,管控值为80%。\n池1污泥体积指数:当前值为133.13mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.66mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4111. "conversations": [
  4112. {
  4113. "from": "human",
  4114. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  4115. },
  4116. {
  4117. "from": "gpt",
  4118. "value": "不正常"
  4119. },
  4120. {
  4121. "from": "human",
  4122. "value": "状态:仪表不正常\n解决方案:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
  4123. }
  4124. ]
  4125. },
  4126. {
  4127. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.20mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.23mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为500.79mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.85%,管控值为80%。\n池2污泥沉降比:当前值为59.26%,管控值为80%。\n池1污泥体积指数:当前值为135.49mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.08mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4128. "conversations": [
  4129. {
  4130. "from": "human",
  4131. "value": "进水COD高于设计值?"
  4132. },
  4133. {
  4134. "from": "gpt",
  4135. "value": "低于设计值"
  4136. },
  4137. {
  4138. "from": "human",
  4139. "value": "进水总量与设计值的比较是?"
  4140. },
  4141. {
  4142. "from": "gpt",
  4143. "value": "小于设计值"
  4144. },
  4145. {
  4146. "from": "human",
  4147. "value": ""
  4148. }
  4149. ]
  4150. },
  4151. {
  4152. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.70mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.00mg/L,设计值为630mg/L。\n进水水温:当前值是11.52℃。\n进水TDS:当前值为502.74mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.03%,管控值为80%。\n池2污泥沉降比:当前值为59.30%,管控值为80%。\n池1污泥体积指数:当前值为136.20mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.46mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4153. "conversations": [
  4154. {
  4155. "from": "human",
  4156. "value": "进水COD高于设计值?"
  4157. },
  4158. {
  4159. "from": "gpt",
  4160. "value": "低于设计值"
  4161. },
  4162. {
  4163. "from": "human",
  4164. "value": "进水总量与设计值的比较是?"
  4165. },
  4166. {
  4167. "from": "gpt",
  4168. "value": "大于但未超过110%"
  4169. },
  4170. {
  4171. "from": "human",
  4172. "value": "状态:进水COD未超设计值,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  4173. }
  4174. ]
  4175. },
  4176. {
  4177. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.18mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.18mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为503.04mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.84%,管控值为80%。\n池2污泥沉降比:当前值为59.49%,管控值为80%。\n池1污泥体积指数:当前值为135.06mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.90mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4178. "conversations": [
  4179. {
  4180. "from": "human",
  4181. "value": "进水COD高于设计值?"
  4182. },
  4183. {
  4184. "from": "gpt",
  4185. "value": "低于设计值"
  4186. },
  4187. {
  4188. "from": "human",
  4189. "value": "进水总量与设计值的比较是?"
  4190. },
  4191. {
  4192. "from": "gpt",
  4193. "value": "超过110%"
  4194. },
  4195. {
  4196. "from": "human",
  4197. "value": "状态:进水COD未超设计值,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  4198. }
  4199. ]
  4200. },
  4201. {
  4202. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.64mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为649.68mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为503.04mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.09%,管控值为80%。\n池2污泥沉降比:当前值为59.31%,管控值为80%。\n池1污泥体积指数:当前值为133.78mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.50mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4203. "conversations": [
  4204. {
  4205. "from": "human",
  4206. "value": "进水COD高于设计值?"
  4207. },
  4208. {
  4209. "from": "gpt",
  4210. "value": "高于设计值但是低于110%"
  4211. },
  4212. {
  4213. "from": "human",
  4214. "value": "进水总量与设计值的比较是?"
  4215. },
  4216. {
  4217. "from": "gpt",
  4218. "value": "小于设计值"
  4219. },
  4220. {
  4221. "from": "human",
  4222. "value": ""
  4223. }
  4224. ]
  4225. },
  4226. {
  4227. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.85mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为648.57mg/L,设计值为630mg/L。\n进水水温:当前值是11.55℃。\n进水TDS:当前值为500.62mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.95%,管控值为80%。\n池2污泥沉降比:当前值为59.56%,管控值为80%。\n池1污泥体积指数:当前值为135.46mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.61mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4228. "conversations": [
  4229. {
  4230. "from": "human",
  4231. "value": "进水COD高于设计值?"
  4232. },
  4233. {
  4234. "from": "gpt",
  4235. "value": "高于设计值但是低于110%"
  4236. },
  4237. {
  4238. "from": "human",
  4239. "value": "进水总量与设计值的比较是?"
  4240. },
  4241. {
  4242. "from": "gpt",
  4243. "value": "大于但未超过110%"
  4244. },
  4245. {
  4246. "from": "human",
  4247. "value": "状态:进水COD未超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  4248. }
  4249. ]
  4250. },
  4251. {
  4252. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.97mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为651.58mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为502.53mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.73%,管控值为80%。\n池2污泥沉降比:当前值为60.11%,管控值为80%。\n池1污泥体积指数:当前值为135.98mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.37mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4253. "conversations": [
  4254. {
  4255. "from": "human",
  4256. "value": "进水COD高于设计值?"
  4257. },
  4258. {
  4259. "from": "gpt",
  4260. "value": "高于设计值但是低于110%"
  4261. },
  4262. {
  4263. "from": "human",
  4264. "value": "进水总量与设计值的比较是?"
  4265. },
  4266. {
  4267. "from": "gpt",
  4268. "value": "超过110%"
  4269. },
  4270. {
  4271. "from": "human",
  4272. "value": "状态:进水COD未超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  4273. }
  4274. ]
  4275. },
  4276. {
  4277. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.42mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.82mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为501.87mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.12%,管控值为80%。\n池2污泥沉降比:当前值为59.07%,管控值为80%。\n池1污泥体积指数:当前值为135.81mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.01mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4278. "conversations": [
  4279. {
  4280. "from": "human",
  4281. "value": "进水COD高于设计值?"
  4282. },
  4283. {
  4284. "from": "gpt",
  4285. "value": "高于设计值110%"
  4286. },
  4287. {
  4288. "from": "human",
  4289. "value": "进水总量与设计值的比较是?"
  4290. },
  4291. {
  4292. "from": "gpt",
  4293. "value": "小于设计值"
  4294. },
  4295. {
  4296. "from": "human",
  4297. "value": ""
  4298. }
  4299. ]
  4300. },
  4301. {
  4302. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.68mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.27mg/L,设计值为630mg/L。\n进水水温:当前值是11.53℃。\n进水TDS:当前值为502.34mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.53%,管控值为80%。\n池2污泥沉降比:当前值为59.65%,管控值为80%。\n池1污泥体积指数:当前值为133.23mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.69mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4303. "conversations": [
  4304. {
  4305. "from": "human",
  4306. "value": "进水COD高于设计值?"
  4307. },
  4308. {
  4309. "from": "gpt",
  4310. "value": "高于设计值110%"
  4311. },
  4312. {
  4313. "from": "human",
  4314. "value": "进水总量与设计值的比较是?"
  4315. },
  4316. {
  4317. "from": "gpt",
  4318. "value": "大于但未超过110%"
  4319. },
  4320. {
  4321. "from": "human",
  4322. "value": "状态:进水COD超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  4323. }
  4324. ]
  4325. },
  4326. {
  4327. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.54mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.03mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为501.89mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.97%,管控值为80%。\n池2污泥沉降比:当前值为60.22%,管控值为80%。\n池1污泥体积指数:当前值为135.73mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.79mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4328. "conversations": [
  4329. {
  4330. "from": "human",
  4331. "value": "进水COD高于设计值?"
  4332. },
  4333. {
  4334. "from": "gpt",
  4335. "value": "高于设计值110%"
  4336. },
  4337. {
  4338. "from": "human",
  4339. "value": "进水总量与设计值的比较是?"
  4340. },
  4341. {
  4342. "from": "gpt",
  4343. "value": "超过110%"
  4344. },
  4345. {
  4346. "from": "human",
  4347. "value": "状态:进水COD超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  4348. }
  4349. ]
  4350. },
  4351. {
  4352. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.81mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.31mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为501.98mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.67%,管控值为80%。\n池2污泥沉降比:当前值为59.92%,管控值为80%。\n池1污泥体积指数:当前值为135.65mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.53mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为3.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4353. "conversations": [
  4354. {
  4355. "from": "human",
  4356. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  4357. },
  4358. {
  4359. "from": "gpt",
  4360. "value": "都未低于"
  4361. },
  4362. {
  4363. "from": "human",
  4364. "value": ""
  4365. }
  4366. ]
  4367. },
  4368. {
  4369. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.94mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.43mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.05mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.82%,管控值为80%。\n池2污泥沉降比:当前值为59.18%,管控值为80%。\n池1污泥体积指数:当前值为133.09mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.68mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4370. "conversations": [
  4371. {
  4372. "from": "human",
  4373. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  4374. },
  4375. {
  4376. "from": "gpt",
  4377. "value": "至少一个池子有低于"
  4378. },
  4379. {
  4380. "from": "human",
  4381. "value": "状态:好氧池溶解氧偏低\n解决方案:\n1、解决供风量不足导致的生化池DO过低\n首先查看风机状态,尝试提高已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,启动或切换备用风机,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决曝气管路不畅、漏气等导致的生化池DO过低\n(1)定期及时排出曝气管路中的领凝水保障管路通常。(2)水面上漏点直接维修;水面下漏点,具备停进水条件的放空后维修,不具备的则按环保要求完成备案同意后,争取最短时间内恢复,在此期间根据实际情况灵活采取过渡措施予以保障。\n3、供风量充足,解决曝气器破损或脱落等导致的生化池DO过低\n关闭或调小泄漏处阀门,减小气量损失,保障生化池充氧效果。具备停水放空条件,及时维修或更换。在此期间根据实际情况灵活采取过渡措施予以保障。\n4、供风量充足,解决生化池负或液位差异导致生化池气量分配不均导致的DO过低\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
  4382. }
  4383. ]
  4384. },
  4385. {
  4386. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.88mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.42mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为501.03mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.97%,管控值为80%。\n池2污泥沉降比:当前值为60.52%,管控值为80%。\n池1污泥体积指数:当前值为133.88mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.37mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4387. "conversations": [
  4388. {
  4389. "from": "human",
  4390. "value": "进水水温是否小于8℃"
  4391. },
  4392. {
  4393. "from": "gpt",
  4394. "value": "否"
  4395. },
  4396. {
  4397. "from": "human",
  4398. "value": ""
  4399. }
  4400. ]
  4401. },
  4402. {
  4403. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.22mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.84mg/L,设计值为630mg/L。\n\n进水水温:当前值是3.50℃。\n进水TDS:当前值为502.62mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.35%,管控值为80%。\n池2污泥沉降比:当前值为59.16%,管控值为80%。\n池1污泥体积指数:当前值为136.49mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.68mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4404. "conversations": [
  4405. {
  4406. "from": "human",
  4407. "value": "进水水温是否小于8℃"
  4408. },
  4409. {
  4410. "from": "gpt",
  4411. "value": "是"
  4412. },
  4413. {
  4414. "from": "human",
  4415. "value": "状态:进水水温小于8℃\n由于水温低于10℃,聚磷菌在低温时生长速度会减慢,生物除磷速率将会迅速下降,微生物活性下降。\n解决方案:\n1、强化温降数据收集与分析,提前预警管控\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时,加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n(1)适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(COD不超过150mg/L)情况下,也可控制在20~25天。\n(2)合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n(3)及时调控回流比,温降或换季期间,较常规运行阶段要适当提高外回流比,一般不超过150%。内回流比则根据总氮变化灵活调整,内外总回流比不宜超过400%。"
  4416. }
  4417. ]
  4418. },
  4419. {
  4420. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.96mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.15mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为501.57mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.73%,管控值为80%。\n池2污泥沉降比:当前值为59.75%,管控值为80%。\n池1污泥体积指数:当前值为133.50mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.92mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4421. "conversations": [
  4422. {
  4423. "from": "human",
  4424. "value": "进水TDS是否超出管控值?"
  4425. },
  4426. {
  4427. "from": "gpt",
  4428. "value": "未超出"
  4429. },
  4430. {
  4431. "from": "human",
  4432. "value": ""
  4433. }
  4434. ]
  4435. },
  4436. {
  4437. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.76mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.65mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为650.14mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.45%,管控值为80%。\n池2污泥沉降比:当前值为60.70%,管控值为80%。\n池1污泥体积指数:当前值为135.92mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.65mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4438. "conversations": [
  4439. {
  4440. "from": "human",
  4441. "value": "进水TDS是否超出管控值?"
  4442. },
  4443. {
  4444. "from": "gpt",
  4445. "value": "超出"
  4446. },
  4447. {
  4448. "from": "human",
  4449. "value": "状态:进水TDS超过管控值\n解决方案:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争在第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力。\n3、毒性小试实验方案\n将现有生化系统活性污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下开展闷曝小试实验,每 8h 取样 1 次,24h 换水 1 次(换水量为 50%),连续运行 72h,比较不同进水 COD、NH3-N 污染物去除效率,根据实验结果确定:① 探究污水厂进水是否对活性良好的微生物菌群产生延时毒性抑制作用;② 探究生化系统内活性污泥的硝化效能;③探究解决当前生化池硝化抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,化系统COD去除率50%以上且不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,COD去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  4450. }
  4451. ]
  4452. },
  4453. {
  4454. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.38mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.27mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为501.08mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.41%,管控值为80%。\n池2污泥沉降比:当前值为60.62%,管控值为80%。\n池1污泥体积指数:当前值为134.18mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.31mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4455. "conversations": [
  4456. {
  4457. "from": "human",
  4458. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  4459. },
  4460. {
  4461. "from": "gpt",
  4462. "value": "都未超过"
  4463. },
  4464. {
  4465. "from": "human",
  4466. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  4467. },
  4468. {
  4469. "from": "gpt",
  4470. "value": "否"
  4471. },
  4472. {
  4473. "from": "human",
  4474. "value": ""
  4475. }
  4476. ]
  4477. },
  4478. {
  4479. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.25mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.38mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为502.14mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.38%,管控值为80%。\n池2污泥沉降比:当前值为59.21%,管控值为80%。\n池1污泥体积指数:当前值为134.79mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.87mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4480. "conversations": [
  4481. {
  4482. "from": "human",
  4483. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  4484. },
  4485. {
  4486. "from": "gpt",
  4487. "value": "都未超过"
  4488. },
  4489. {
  4490. "from": "human",
  4491. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  4492. },
  4493. {
  4494. "from": "gpt",
  4495. "value": "是"
  4496. },
  4497. {
  4498. "from": "human",
  4499. "value": "状态:生化池有大量泡沫、浮泥等不正常现象\n由于生化池出现大量泡沫、浮泥等不正常现象,可能是污泥膨胀、老化、解絮等导致微生物活性下降,导致出水带泥。\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  4500. }
  4501. ]
  4502. },
  4503. {
  4504. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.34mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.35mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为501.39mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.50%,管控值为80%。\n池2污泥沉降比:当前值为89.38%,管控值为80%。\n池1污泥体积指数:当前值为135.65mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.10mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4505. "conversations": [
  4506. {
  4507. "from": "human",
  4508. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  4509. },
  4510. {
  4511. "from": "gpt",
  4512. "value": "至少一个池子有超过"
  4513. },
  4514. {
  4515. "from": "human",
  4516. "value": "状态:污泥沉降比或污泥体积指数异常\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  4517. }
  4518. ]
  4519. },
  4520. {
  4521. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n\n出水COD:当前值为35.47mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.66mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为501.83mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.13%,管控值为80%。\n池2污泥沉降比:当前值为59.91%,管控值为80%。\n池1污泥体积指数:当前值为134.72mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.70mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4522. "conversations": [
  4523. {
  4524. "from": "human",
  4525. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  4526. },
  4527. {
  4528. "from": "gpt",
  4529. "value": "正常"
  4530. },
  4531. {
  4532. "from": "human",
  4533. "value": "出水COD是否连续两次超标?"
  4534. },
  4535. {
  4536. "from": "gpt",
  4537. "value": "存在"
  4538. },
  4539. {
  4540. "from": "human",
  4541. "value": "状态:基本确认出水COD超标了\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  4542. }
  4543. ]
  4544. },
  4545. {
  4546. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.64mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.51mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为502.66mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.50%,管控值为80%。\n池2污泥沉降比:当前值为60.58%,管控值为80%。\n池1污泥体积指数:当前值为135.81mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.63mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4547. "conversations": [
  4548. {
  4549. "from": "human",
  4550. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  4551. },
  4552. {
  4553. "from": "gpt",
  4554. "value": "正常"
  4555. },
  4556. {
  4557. "from": "human",
  4558. "value": "出水COD是否连续两次超标?"
  4559. },
  4560. {
  4561. "from": "gpt",
  4562. "value": "不存在"
  4563. },
  4564. {
  4565. "from": "human",
  4566. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  4567. },
  4568. {
  4569. "from": "gpt",
  4570. "value": "超标"
  4571. },
  4572. {
  4573. "from": "human",
  4574. "value": "状态:人工化验比对,出水COD超标了。\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  4575. }
  4576. ]
  4577. },
  4578. {
  4579. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.49mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.50mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为502.16mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.40%,管控值为80%。\n池2污泥沉降比:当前值为59.19%,管控值为80%。\n池1污泥体积指数:当前值为136.21mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.09mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4580. "conversations": [
  4581. {
  4582. "from": "human",
  4583. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  4584. },
  4585. {
  4586. "from": "gpt",
  4587. "value": "正常"
  4588. },
  4589. {
  4590. "from": "human",
  4591. "value": "出水COD是否连续两次超标?"
  4592. },
  4593. {
  4594. "from": "gpt",
  4595. "value": "不存在"
  4596. },
  4597. {
  4598. "from": "human",
  4599. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  4600. },
  4601. {
  4602. "from": "gpt",
  4603. "value": "不超标"
  4604. },
  4605. {
  4606. "from": "human",
  4607. "value": "状态:人工化验出水COD不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
  4608. }
  4609. ]
  4610. },
  4611. {
  4612. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为-0.04mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.77mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.98mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.47%,管控值为80%。\n池2污泥沉降比:当前值为59.80%,管控值为80%。\n池1污泥体积指数:当前值为133.88mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.30mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4613. "conversations": [
  4614. {
  4615. "from": "human",
  4616. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  4617. },
  4618. {
  4619. "from": "gpt",
  4620. "value": "不正常"
  4621. },
  4622. {
  4623. "from": "human",
  4624. "value": "状态:仪表不正常\n解决方案:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
  4625. }
  4626. ]
  4627. },
  4628. {
  4629. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.23mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.93mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为503.21mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.30%,管控值为80%。\n池2污泥沉降比:当前值为59.08%,管控值为80%。\n池1污泥体积指数:当前值为133.43mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.51mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4630. "conversations": [
  4631. {
  4632. "from": "human",
  4633. "value": "进水COD高于设计值?"
  4634. },
  4635. {
  4636. "from": "gpt",
  4637. "value": "低于设计值"
  4638. },
  4639. {
  4640. "from": "human",
  4641. "value": "进水总量与设计值的比较是?"
  4642. },
  4643. {
  4644. "from": "gpt",
  4645. "value": "小于设计值"
  4646. },
  4647. {
  4648. "from": "human",
  4649. "value": ""
  4650. }
  4651. ]
  4652. },
  4653. {
  4654. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.80mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.25mg/L,设计值为630mg/L。\n进水水温:当前值是11.54℃。\n进水TDS:当前值为501.81mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.67%,管控值为80%。\n池2污泥沉降比:当前值为60.49%,管控值为80%。\n池1污泥体积指数:当前值为134.34mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.02mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4655. "conversations": [
  4656. {
  4657. "from": "human",
  4658. "value": "进水COD高于设计值?"
  4659. },
  4660. {
  4661. "from": "gpt",
  4662. "value": "低于设计值"
  4663. },
  4664. {
  4665. "from": "human",
  4666. "value": "进水总量与设计值的比较是?"
  4667. },
  4668. {
  4669. "from": "gpt",
  4670. "value": "大于但未超过110%"
  4671. },
  4672. {
  4673. "from": "human",
  4674. "value": "状态:进水COD未超设计值,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  4675. }
  4676. ]
  4677. },
  4678. {
  4679. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.91mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.04mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为500.04mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.39%,管控值为80%。\n池2污泥沉降比:当前值为59.12%,管控值为80%。\n池1污泥体积指数:当前值为133.95mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.15mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4680. "conversations": [
  4681. {
  4682. "from": "human",
  4683. "value": "进水COD高于设计值?"
  4684. },
  4685. {
  4686. "from": "gpt",
  4687. "value": "低于设计值"
  4688. },
  4689. {
  4690. "from": "human",
  4691. "value": "进水总量与设计值的比较是?"
  4692. },
  4693. {
  4694. "from": "gpt",
  4695. "value": "超过110%"
  4696. },
  4697. {
  4698. "from": "human",
  4699. "value": "状态:进水COD未超设计值,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  4700. }
  4701. ]
  4702. },
  4703. {
  4704. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.87mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为649.04mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为503.71mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.00%,管控值为80%。\n池2污泥沉降比:当前值为59.68%,管控值为80%。\n池1污泥体积指数:当前值为133.17mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.41mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4705. "conversations": [
  4706. {
  4707. "from": "human",
  4708. "value": "进水COD高于设计值?"
  4709. },
  4710. {
  4711. "from": "gpt",
  4712. "value": "高于设计值但是低于110%"
  4713. },
  4714. {
  4715. "from": "human",
  4716. "value": "进水总量与设计值的比较是?"
  4717. },
  4718. {
  4719. "from": "gpt",
  4720. "value": "小于设计值"
  4721. },
  4722. {
  4723. "from": "human",
  4724. "value": ""
  4725. }
  4726. ]
  4727. },
  4728. {
  4729. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.15mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为650.91mg/L,设计值为630mg/L。\n进水水温:当前值是11.52℃。\n进水TDS:当前值为500.53mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.70%,管控值为80%。\n池2污泥沉降比:当前值为60.18%,管控值为80%。\n池1污泥体积指数:当前值为135.53mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.58mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4730. "conversations": [
  4731. {
  4732. "from": "human",
  4733. "value": "进水COD高于设计值?"
  4734. },
  4735. {
  4736. "from": "gpt",
  4737. "value": "高于设计值但是低于110%"
  4738. },
  4739. {
  4740. "from": "human",
  4741. "value": "进水总量与设计值的比较是?"
  4742. },
  4743. {
  4744. "from": "gpt",
  4745. "value": "大于但未超过110%"
  4746. },
  4747. {
  4748. "from": "human",
  4749. "value": "状态:进水COD未超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  4750. }
  4751. ]
  4752. },
  4753. {
  4754. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.49mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为649.64mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为500.89mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.73%,管控值为80%。\n池2污泥沉降比:当前值为60.50%,管控值为80%。\n池1污泥体积指数:当前值为133.24mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.28mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4755. "conversations": [
  4756. {
  4757. "from": "human",
  4758. "value": "进水COD高于设计值?"
  4759. },
  4760. {
  4761. "from": "gpt",
  4762. "value": "高于设计值但是低于110%"
  4763. },
  4764. {
  4765. "from": "human",
  4766. "value": "进水总量与设计值的比较是?"
  4767. },
  4768. {
  4769. "from": "gpt",
  4770. "value": "超过110%"
  4771. },
  4772. {
  4773. "from": "human",
  4774. "value": "状态:进水COD未超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  4775. }
  4776. ]
  4777. },
  4778. {
  4779. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.42mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.14mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为502.31mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.32%,管控值为80%。\n池2污泥沉降比:当前值为59.71%,管控值为80%。\n池1污泥体积指数:当前值为135.21mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.42mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4780. "conversations": [
  4781. {
  4782. "from": "human",
  4783. "value": "进水COD高于设计值?"
  4784. },
  4785. {
  4786. "from": "gpt",
  4787. "value": "高于设计值110%"
  4788. },
  4789. {
  4790. "from": "human",
  4791. "value": "进水总量与设计值的比较是?"
  4792. },
  4793. {
  4794. "from": "gpt",
  4795. "value": "小于设计值"
  4796. },
  4797. {
  4798. "from": "human",
  4799. "value": ""
  4800. }
  4801. ]
  4802. },
  4803. {
  4804. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.75mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.50mg/L,设计值为630mg/L。\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.67mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.46%,管控值为80%。\n池2污泥沉降比:当前值为59.11%,管控值为80%。\n池1污泥体积指数:当前值为133.20mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.99mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4805. "conversations": [
  4806. {
  4807. "from": "human",
  4808. "value": "进水COD高于设计值?"
  4809. },
  4810. {
  4811. "from": "gpt",
  4812. "value": "高于设计值110%"
  4813. },
  4814. {
  4815. "from": "human",
  4816. "value": "进水总量与设计值的比较是?"
  4817. },
  4818. {
  4819. "from": "gpt",
  4820. "value": "大于但未超过110%"
  4821. },
  4822. {
  4823. "from": "human",
  4824. "value": "状态:进水COD超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  4825. }
  4826. ]
  4827. },
  4828. {
  4829. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.49mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.81mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为503.28mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.34%,管控值为80%。\n池2污泥沉降比:当前值为59.84%,管控值为80%。\n池1污泥体积指数:当前值为134.15mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.23mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4830. "conversations": [
  4831. {
  4832. "from": "human",
  4833. "value": "进水COD高于设计值?"
  4834. },
  4835. {
  4836. "from": "gpt",
  4837. "value": "高于设计值110%"
  4838. },
  4839. {
  4840. "from": "human",
  4841. "value": "进水总量与设计值的比较是?"
  4842. },
  4843. {
  4844. "from": "gpt",
  4845. "value": "超过110%"
  4846. },
  4847. {
  4848. "from": "human",
  4849. "value": "状态:进水COD超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  4850. }
  4851. ]
  4852. },
  4853. {
  4854. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.60mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.70mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为501.86mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.31%,管控值为80%。\n池2污泥沉降比:当前值为60.42%,管控值为80%。\n池1污泥体积指数:当前值为135.48mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.91mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为3.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4855. "conversations": [
  4856. {
  4857. "from": "human",
  4858. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  4859. },
  4860. {
  4861. "from": "gpt",
  4862. "value": "都未低于"
  4863. },
  4864. {
  4865. "from": "human",
  4866. "value": ""
  4867. }
  4868. ]
  4869. },
  4870. {
  4871. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.75mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.07mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为502.13mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.18%,管控值为80%。\n池2污泥沉降比:当前值为59.75%,管控值为80%。\n池1污泥体积指数:当前值为133.72mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.78mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4872. "conversations": [
  4873. {
  4874. "from": "human",
  4875. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  4876. },
  4877. {
  4878. "from": "gpt",
  4879. "value": "至少一个池子有低于"
  4880. },
  4881. {
  4882. "from": "human",
  4883. "value": "状态:好氧池溶解氧偏低\n解决方案:\n1、解决供风量不足导致的生化池DO过低\n首先查看风机状态,尝试提高已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,启动或切换备用风机,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决曝气管路不畅、漏气等导致的生化池DO过低\n(1)定期及时排出曝气管路中的领凝水保障管路通常。(2)水面上漏点直接维修;水面下漏点,具备停进水条件的放空后维修,不具备的则按环保要求完成备案同意后,争取最短时间内恢复,在此期间根据实际情况灵活采取过渡措施予以保障。\n3、供风量充足,解决曝气器破损或脱落等导致的生化池DO过低\n关闭或调小泄漏处阀门,减小气量损失,保障生化池充氧效果。具备停水放空条件,及时维修或更换。在此期间根据实际情况灵活采取过渡措施予以保障。\n4、供风量充足,解决生化池负或液位差异导致生化池气量分配不均导致的DO过低\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
  4884. }
  4885. ]
  4886. },
  4887. {
  4888. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.94mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.93mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.92mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.26%,管控值为80%。\n池2污泥沉降比:当前值为59.22%,管控值为80%。\n池1污泥体积指数:当前值为135.96mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.62mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4889. "conversations": [
  4890. {
  4891. "from": "human",
  4892. "value": "进水水温是否小于8℃"
  4893. },
  4894. {
  4895. "from": "gpt",
  4896. "value": "否"
  4897. },
  4898. {
  4899. "from": "human",
  4900. "value": ""
  4901. }
  4902. ]
  4903. },
  4904. {
  4905. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.66mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.00mg/L,设计值为630mg/L。\n\n进水水温:当前值是3.54℃。\n进水TDS:当前值为501.11mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.77%,管控值为80%。\n池2污泥沉降比:当前值为60.17%,管控值为80%。\n池1污泥体积指数:当前值为133.54mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.68mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4906. "conversations": [
  4907. {
  4908. "from": "human",
  4909. "value": "进水水温是否小于8℃"
  4910. },
  4911. {
  4912. "from": "gpt",
  4913. "value": "是"
  4914. },
  4915. {
  4916. "from": "human",
  4917. "value": "状态:进水水温小于8℃\n由于水温低于10℃,聚磷菌在低温时生长速度会减慢,生物除磷速率将会迅速下降,微生物活性下降。\n解决方案:\n1、强化温降数据收集与分析,提前预警管控\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时,加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n(1)适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(COD不超过150mg/L)情况下,也可控制在20~25天。\n(2)合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n(3)及时调控回流比,温降或换季期间,较常规运行阶段要适当提高外回流比,一般不超过150%。内回流比则根据总氮变化灵活调整,内外总回流比不宜超过400%。"
  4918. }
  4919. ]
  4920. },
  4921. {
  4922. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.73mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.34mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为501.85mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.54%,管控值为80%。\n池2污泥沉降比:当前值为59.43%,管控值为80%。\n池1污泥体积指数:当前值为133.67mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.91mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4923. "conversations": [
  4924. {
  4925. "from": "human",
  4926. "value": "进水TDS是否超出管控值?"
  4927. },
  4928. {
  4929. "from": "gpt",
  4930. "value": "未超出"
  4931. },
  4932. {
  4933. "from": "human",
  4934. "value": ""
  4935. }
  4936. ]
  4937. },
  4938. {
  4939. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.19mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.85mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为651.84mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.87%,管控值为80%。\n池2污泥沉降比:当前值为59.66%,管控值为80%。\n池1污泥体积指数:当前值为135.52mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.09mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4940. "conversations": [
  4941. {
  4942. "from": "human",
  4943. "value": "进水TDS是否超出管控值?"
  4944. },
  4945. {
  4946. "from": "gpt",
  4947. "value": "超出"
  4948. },
  4949. {
  4950. "from": "human",
  4951. "value": "状态:进水TDS超过管控值\n解决方案:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争在第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力。\n3、毒性小试实验方案\n将现有生化系统活性污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下开展闷曝小试实验,每 8h 取样 1 次,24h 换水 1 次(换水量为 50%),连续运行 72h,比较不同进水 COD、NH3-N 污染物去除效率,根据实验结果确定:① 探究污水厂进水是否对活性良好的微生物菌群产生延时毒性抑制作用;② 探究生化系统内活性污泥的硝化效能;③探究解决当前生化池硝化抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,化系统COD去除率50%以上且不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,COD去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  4952. }
  4953. ]
  4954. },
  4955. {
  4956. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.70mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.69mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为501.36mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.72%,管控值为80%。\n池2污泥沉降比:当前值为61.00%,管控值为80%。\n池1污泥体积指数:当前值为133.13mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.72mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4957. "conversations": [
  4958. {
  4959. "from": "human",
  4960. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  4961. },
  4962. {
  4963. "from": "gpt",
  4964. "value": "都未超过"
  4965. },
  4966. {
  4967. "from": "human",
  4968. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  4969. },
  4970. {
  4971. "from": "gpt",
  4972. "value": "否"
  4973. },
  4974. {
  4975. "from": "human",
  4976. "value": ""
  4977. }
  4978. ]
  4979. },
  4980. {
  4981. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.58mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.94mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为500.78mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.94%,管控值为80%。\n池2污泥沉降比:当前值为60.69%,管控值为80%。\n池1污泥体积指数:当前值为135.10mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.81mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  4982. "conversations": [
  4983. {
  4984. "from": "human",
  4985. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  4986. },
  4987. {
  4988. "from": "gpt",
  4989. "value": "都未超过"
  4990. },
  4991. {
  4992. "from": "human",
  4993. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  4994. },
  4995. {
  4996. "from": "gpt",
  4997. "value": "是"
  4998. },
  4999. {
  5000. "from": "human",
  5001. "value": "状态:生化池有大量泡沫、浮泥等不正常现象\n由于生化池出现大量泡沫、浮泥等不正常现象,可能是污泥膨胀、老化、解絮等导致微生物活性下降,导致出水带泥。\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  5002. }
  5003. ]
  5004. },
  5005. {
  5006. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.38mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.42mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.55mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.96%,管控值为80%。\n池2污泥沉降比:当前值为89.71%,管控值为80%。\n池1污泥体积指数:当前值为133.95mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.65mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5007. "conversations": [
  5008. {
  5009. "from": "human",
  5010. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  5011. },
  5012. {
  5013. "from": "gpt",
  5014. "value": "至少一个池子有超过"
  5015. },
  5016. {
  5017. "from": "human",
  5018. "value": "状态:污泥沉降比或污泥体积指数异常\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  5019. }
  5020. ]
  5021. },
  5022. {
  5023. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n\n出水COD:当前值为36.47mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.72mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为502.85mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.32%,管控值为80%。\n池2污泥沉降比:当前值为59.44%,管控值为80%。\n池1污泥体积指数:当前值为134.98mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.04mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5024. "conversations": [
  5025. {
  5026. "from": "human",
  5027. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  5028. },
  5029. {
  5030. "from": "gpt",
  5031. "value": "正常"
  5032. },
  5033. {
  5034. "from": "human",
  5035. "value": "出水COD是否连续两次超标?"
  5036. },
  5037. {
  5038. "from": "gpt",
  5039. "value": "存在"
  5040. },
  5041. {
  5042. "from": "human",
  5043. "value": "状态:基本确认出水COD超标了\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  5044. }
  5045. ]
  5046. },
  5047. {
  5048. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.91mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.15mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为502.93mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.73%,管控值为80%。\n池2污泥沉降比:当前值为59.63%,管控值为80%。\n池1污泥体积指数:当前值为135.24mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.68mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5049. "conversations": [
  5050. {
  5051. "from": "human",
  5052. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  5053. },
  5054. {
  5055. "from": "gpt",
  5056. "value": "正常"
  5057. },
  5058. {
  5059. "from": "human",
  5060. "value": "出水COD是否连续两次超标?"
  5061. },
  5062. {
  5063. "from": "gpt",
  5064. "value": "不存在"
  5065. },
  5066. {
  5067. "from": "human",
  5068. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  5069. },
  5070. {
  5071. "from": "gpt",
  5072. "value": "超标"
  5073. },
  5074. {
  5075. "from": "human",
  5076. "value": "状态:人工化验比对,出水COD超标了。\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  5077. }
  5078. ]
  5079. },
  5080. {
  5081. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.06mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.14mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为501.72mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.52%,管控值为80%。\n池2污泥沉降比:当前值为60.71%,管控值为80%。\n池1污泥体积指数:当前值为134.74mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.38mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5082. "conversations": [
  5083. {
  5084. "from": "human",
  5085. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  5086. },
  5087. {
  5088. "from": "gpt",
  5089. "value": "正常"
  5090. },
  5091. {
  5092. "from": "human",
  5093. "value": "出水COD是否连续两次超标?"
  5094. },
  5095. {
  5096. "from": "gpt",
  5097. "value": "不存在"
  5098. },
  5099. {
  5100. "from": "human",
  5101. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  5102. },
  5103. {
  5104. "from": "gpt",
  5105. "value": "不超标"
  5106. },
  5107. {
  5108. "from": "human",
  5109. "value": "状态:人工化验出水COD不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
  5110. }
  5111. ]
  5112. },
  5113. {
  5114. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为-0.02mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.77mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为501.04mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.81%,管控值为80%。\n池2污泥沉降比:当前值为60.22%,管控值为80%。\n池1污泥体积指数:当前值为135.85mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.29mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5115. "conversations": [
  5116. {
  5117. "from": "human",
  5118. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  5119. },
  5120. {
  5121. "from": "gpt",
  5122. "value": "不正常"
  5123. },
  5124. {
  5125. "from": "human",
  5126. "value": "状态:仪表不正常\n解决方案:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
  5127. }
  5128. ]
  5129. },
  5130. {
  5131. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.13mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.53mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为502.89mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.92%,管控值为80%。\n池2污泥沉降比:当前值为60.77%,管控值为80%。\n池1污泥体积指数:当前值为134.89mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.83mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5132. "conversations": [
  5133. {
  5134. "from": "human",
  5135. "value": "进水COD高于设计值?"
  5136. },
  5137. {
  5138. "from": "gpt",
  5139. "value": "低于设计值"
  5140. },
  5141. {
  5142. "from": "human",
  5143. "value": "进水总量与设计值的比较是?"
  5144. },
  5145. {
  5146. "from": "gpt",
  5147. "value": "小于设计值"
  5148. },
  5149. {
  5150. "from": "human",
  5151. "value": ""
  5152. }
  5153. ]
  5154. },
  5155. {
  5156. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.33mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.41mg/L,设计值为630mg/L。\n进水水温:当前值是11.54℃。\n进水TDS:当前值为500.20mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.22%,管控值为80%。\n池2污泥沉降比:当前值为60.06%,管控值为80%。\n池1污泥体积指数:当前值为135.02mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.41mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5157. "conversations": [
  5158. {
  5159. "from": "human",
  5160. "value": "进水COD高于设计值?"
  5161. },
  5162. {
  5163. "from": "gpt",
  5164. "value": "低于设计值"
  5165. },
  5166. {
  5167. "from": "human",
  5168. "value": "进水总量与设计值的比较是?"
  5169. },
  5170. {
  5171. "from": "gpt",
  5172. "value": "大于但未超过110%"
  5173. },
  5174. {
  5175. "from": "human",
  5176. "value": "状态:进水COD未超设计值,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  5177. }
  5178. ]
  5179. },
  5180. {
  5181. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.86mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.60mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为503.45mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.01%,管控值为80%。\n池2污泥沉降比:当前值为60.17%,管控值为80%。\n池1污泥体积指数:当前值为134.74mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.93mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5182. "conversations": [
  5183. {
  5184. "from": "human",
  5185. "value": "进水COD高于设计值?"
  5186. },
  5187. {
  5188. "from": "gpt",
  5189. "value": "低于设计值"
  5190. },
  5191. {
  5192. "from": "human",
  5193. "value": "进水总量与设计值的比较是?"
  5194. },
  5195. {
  5196. "from": "gpt",
  5197. "value": "超过110%"
  5198. },
  5199. {
  5200. "from": "human",
  5201. "value": "状态:进水COD未超设计值,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  5202. }
  5203. ]
  5204. },
  5205. {
  5206. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.72mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为650.89mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.53mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.03%,管控值为80%。\n池2污泥沉降比:当前值为60.95%,管控值为80%。\n池1污泥体积指数:当前值为136.69mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.18mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5207. "conversations": [
  5208. {
  5209. "from": "human",
  5210. "value": "进水COD高于设计值?"
  5211. },
  5212. {
  5213. "from": "gpt",
  5214. "value": "高于设计值但是低于110%"
  5215. },
  5216. {
  5217. "from": "human",
  5218. "value": "进水总量与设计值的比较是?"
  5219. },
  5220. {
  5221. "from": "gpt",
  5222. "value": "小于设计值"
  5223. },
  5224. {
  5225. "from": "human",
  5226. "value": ""
  5227. }
  5228. ]
  5229. },
  5230. {
  5231. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.90mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为650.47mg/L,设计值为630mg/L。\n进水水温:当前值是11.50℃。\n进水TDS:当前值为502.15mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.61%,管控值为80%。\n池2污泥沉降比:当前值为60.84%,管控值为80%。\n池1污泥体积指数:当前值为135.97mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.30mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5232. "conversations": [
  5233. {
  5234. "from": "human",
  5235. "value": "进水COD高于设计值?"
  5236. },
  5237. {
  5238. "from": "gpt",
  5239. "value": "高于设计值但是低于110%"
  5240. },
  5241. {
  5242. "from": "human",
  5243. "value": "进水总量与设计值的比较是?"
  5244. },
  5245. {
  5246. "from": "gpt",
  5247. "value": "大于但未超过110%"
  5248. },
  5249. {
  5250. "from": "human",
  5251. "value": "状态:进水COD未超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  5252. }
  5253. ]
  5254. },
  5255. {
  5256. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.54mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为650.66mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为503.46mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.50%,管控值为80%。\n池2污泥沉降比:当前值为60.81%,管控值为80%。\n池1污泥体积指数:当前值为135.08mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.23mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5257. "conversations": [
  5258. {
  5259. "from": "human",
  5260. "value": "进水COD高于设计值?"
  5261. },
  5262. {
  5263. "from": "gpt",
  5264. "value": "高于设计值但是低于110%"
  5265. },
  5266. {
  5267. "from": "human",
  5268. "value": "进水总量与设计值的比较是?"
  5269. },
  5270. {
  5271. "from": "gpt",
  5272. "value": "超过110%"
  5273. },
  5274. {
  5275. "from": "human",
  5276. "value": "状态:进水COD未超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  5277. }
  5278. ]
  5279. },
  5280. {
  5281. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.29mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.64mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为502.88mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.18%,管控值为80%。\n池2污泥沉降比:当前值为59.31%,管控值为80%。\n池1污泥体积指数:当前值为133.06mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.93mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5282. "conversations": [
  5283. {
  5284. "from": "human",
  5285. "value": "进水COD高于设计值?"
  5286. },
  5287. {
  5288. "from": "gpt",
  5289. "value": "高于设计值110%"
  5290. },
  5291. {
  5292. "from": "human",
  5293. "value": "进水总量与设计值的比较是?"
  5294. },
  5295. {
  5296. "from": "gpt",
  5297. "value": "小于设计值"
  5298. },
  5299. {
  5300. "from": "human",
  5301. "value": ""
  5302. }
  5303. ]
  5304. },
  5305. {
  5306. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.20mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.99mg/L,设计值为630mg/L。\n进水水温:当前值是11.53℃。\n进水TDS:当前值为503.46mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.49%,管控值为80%。\n池2污泥沉降比:当前值为60.85%,管控值为80%。\n池1污泥体积指数:当前值为136.26mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.45mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5307. "conversations": [
  5308. {
  5309. "from": "human",
  5310. "value": "进水COD高于设计值?"
  5311. },
  5312. {
  5313. "from": "gpt",
  5314. "value": "高于设计值110%"
  5315. },
  5316. {
  5317. "from": "human",
  5318. "value": "进水总量与设计值的比较是?"
  5319. },
  5320. {
  5321. "from": "gpt",
  5322. "value": "大于但未超过110%"
  5323. },
  5324. {
  5325. "from": "human",
  5326. "value": "状态:进水COD超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  5327. }
  5328. ]
  5329. },
  5330. {
  5331. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.96mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.57mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为502.57mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.51%,管控值为80%。\n池2污泥沉降比:当前值为60.50%,管控值为80%。\n池1污泥体积指数:当前值为135.68mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.89mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5332. "conversations": [
  5333. {
  5334. "from": "human",
  5335. "value": "进水COD高于设计值?"
  5336. },
  5337. {
  5338. "from": "gpt",
  5339. "value": "高于设计值110%"
  5340. },
  5341. {
  5342. "from": "human",
  5343. "value": "进水总量与设计值的比较是?"
  5344. },
  5345. {
  5346. "from": "gpt",
  5347. "value": "超过110%"
  5348. },
  5349. {
  5350. "from": "human",
  5351. "value": "状态:进水COD超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  5352. }
  5353. ]
  5354. },
  5355. {
  5356. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.81mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.56mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.23mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.81%,管控值为80%。\n池2污泥沉降比:当前值为59.58%,管控值为80%。\n池1污泥体积指数:当前值为134.92mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.81mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为3.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5357. "conversations": [
  5358. {
  5359. "from": "human",
  5360. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  5361. },
  5362. {
  5363. "from": "gpt",
  5364. "value": "都未低于"
  5365. },
  5366. {
  5367. "from": "human",
  5368. "value": ""
  5369. }
  5370. ]
  5371. },
  5372. {
  5373. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.39mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.63mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.73mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.47%,管控值为80%。\n池2污泥沉降比:当前值为59.33%,管控值为80%。\n池1污泥体积指数:当前值为136.94mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.55mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5374. "conversations": [
  5375. {
  5376. "from": "human",
  5377. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  5378. },
  5379. {
  5380. "from": "gpt",
  5381. "value": "至少一个池子有低于"
  5382. },
  5383. {
  5384. "from": "human",
  5385. "value": "状态:好氧池溶解氧偏低\n解决方案:\n1、解决供风量不足导致的生化池DO过低\n首先查看风机状态,尝试提高已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,启动或切换备用风机,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决曝气管路不畅、漏气等导致的生化池DO过低\n(1)定期及时排出曝气管路中的领凝水保障管路通常。(2)水面上漏点直接维修;水面下漏点,具备停进水条件的放空后维修,不具备的则按环保要求完成备案同意后,争取最短时间内恢复,在此期间根据实际情况灵活采取过渡措施予以保障。\n3、供风量充足,解决曝气器破损或脱落等导致的生化池DO过低\n关闭或调小泄漏处阀门,减小气量损失,保障生化池充氧效果。具备停水放空条件,及时维修或更换。在此期间根据实际情况灵活采取过渡措施予以保障。\n4、供风量充足,解决生化池负或液位差异导致生化池气量分配不均导致的DO过低\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
  5386. }
  5387. ]
  5388. },
  5389. {
  5390. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.75mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.82mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为502.75mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.57%,管控值为80%。\n池2污泥沉降比:当前值为60.86%,管控值为80%。\n池1污泥体积指数:当前值为135.85mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.97mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5391. "conversations": [
  5392. {
  5393. "from": "human",
  5394. "value": "进水水温是否小于8℃"
  5395. },
  5396. {
  5397. "from": "gpt",
  5398. "value": "否"
  5399. },
  5400. {
  5401. "from": "human",
  5402. "value": ""
  5403. }
  5404. ]
  5405. },
  5406. {
  5407. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.45mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.19mg/L,设计值为630mg/L。\n\n进水水温:当前值是3.51℃。\n进水TDS:当前值为501.79mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.38%,管控值为80%。\n池2污泥沉降比:当前值为60.42%,管控值为80%。\n池1污泥体积指数:当前值为136.10mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.57mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5408. "conversations": [
  5409. {
  5410. "from": "human",
  5411. "value": "进水水温是否小于8℃"
  5412. },
  5413. {
  5414. "from": "gpt",
  5415. "value": "是"
  5416. },
  5417. {
  5418. "from": "human",
  5419. "value": "状态:进水水温小于8℃\n由于水温低于10℃,聚磷菌在低温时生长速度会减慢,生物除磷速率将会迅速下降,微生物活性下降。\n解决方案:\n1、强化温降数据收集与分析,提前预警管控\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时,加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n(1)适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(COD不超过150mg/L)情况下,也可控制在20~25天。\n(2)合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n(3)及时调控回流比,温降或换季期间,较常规运行阶段要适当提高外回流比,一般不超过150%。内回流比则根据总氮变化灵活调整,内外总回流比不宜超过400%。"
  5420. }
  5421. ]
  5422. },
  5423. {
  5424. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.67mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.35mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为503.89mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.37%,管控值为80%。\n池2污泥沉降比:当前值为59.04%,管控值为80%。\n池1污泥体积指数:当前值为133.80mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.36mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5425. "conversations": [
  5426. {
  5427. "from": "human",
  5428. "value": "进水TDS是否超出管控值?"
  5429. },
  5430. {
  5431. "from": "gpt",
  5432. "value": "未超出"
  5433. },
  5434. {
  5435. "from": "human",
  5436. "value": ""
  5437. }
  5438. ]
  5439. },
  5440. {
  5441. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.37mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.52mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为653.91mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.00%,管控值为80%。\n池2污泥沉降比:当前值为59.21%,管控值为80%。\n池1污泥体积指数:当前值为136.70mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.95mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5442. "conversations": [
  5443. {
  5444. "from": "human",
  5445. "value": "进水TDS是否超出管控值?"
  5446. },
  5447. {
  5448. "from": "gpt",
  5449. "value": "超出"
  5450. },
  5451. {
  5452. "from": "human",
  5453. "value": "状态:进水TDS超过管控值\n解决方案:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争在第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力。\n3、毒性小试实验方案\n将现有生化系统活性污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下开展闷曝小试实验,每 8h 取样 1 次,24h 换水 1 次(换水量为 50%),连续运行 72h,比较不同进水 COD、NH3-N 污染物去除效率,根据实验结果确定:① 探究污水厂进水是否对活性良好的微生物菌群产生延时毒性抑制作用;② 探究生化系统内活性污泥的硝化效能;③探究解决当前生化池硝化抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,化系统COD去除率50%以上且不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,COD去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  5454. }
  5455. ]
  5456. },
  5457. {
  5458. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.77mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.31mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为502.01mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.38%,管控值为80%。\n池2污泥沉降比:当前值为60.92%,管控值为80%。\n池1污泥体积指数:当前值为135.08mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.58mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5459. "conversations": [
  5460. {
  5461. "from": "human",
  5462. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  5463. },
  5464. {
  5465. "from": "gpt",
  5466. "value": "都未超过"
  5467. },
  5468. {
  5469. "from": "human",
  5470. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  5471. },
  5472. {
  5473. "from": "gpt",
  5474. "value": "否"
  5475. },
  5476. {
  5477. "from": "human",
  5478. "value": ""
  5479. }
  5480. ]
  5481. },
  5482. {
  5483. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.19mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.12mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为500.68mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.03%,管控值为80%。\n池2污泥沉降比:当前值为59.79%,管控值为80%。\n池1污泥体积指数:当前值为133.13mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.09mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5484. "conversations": [
  5485. {
  5486. "from": "human",
  5487. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  5488. },
  5489. {
  5490. "from": "gpt",
  5491. "value": "都未超过"
  5492. },
  5493. {
  5494. "from": "human",
  5495. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  5496. },
  5497. {
  5498. "from": "gpt",
  5499. "value": "是"
  5500. },
  5501. {
  5502. "from": "human",
  5503. "value": "状态:生化池有大量泡沫、浮泥等不正常现象\n由于生化池出现大量泡沫、浮泥等不正常现象,可能是污泥膨胀、老化、解絮等导致微生物活性下降,导致出水带泥。\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  5504. }
  5505. ]
  5506. },
  5507. {
  5508. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.66mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.80mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为502.62mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.27%,管控值为80%。\n池2污泥沉降比:当前值为89.53%,管控值为80%。\n池1污泥体积指数:当前值为136.80mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.16mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5509. "conversations": [
  5510. {
  5511. "from": "human",
  5512. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  5513. },
  5514. {
  5515. "from": "gpt",
  5516. "value": "至少一个池子有超过"
  5517. },
  5518. {
  5519. "from": "human",
  5520. "value": "状态:污泥沉降比或污泥体积指数异常\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  5521. }
  5522. ]
  5523. },
  5524. {
  5525. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n\n出水COD:当前值为35.18mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.63mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为502.62mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.16%,管控值为80%。\n池2污泥沉降比:当前值为59.91%,管控值为80%。\n池1污泥体积指数:当前值为134.04mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.59mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5526. "conversations": [
  5527. {
  5528. "from": "human",
  5529. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  5530. },
  5531. {
  5532. "from": "gpt",
  5533. "value": "正常"
  5534. },
  5535. {
  5536. "from": "human",
  5537. "value": "出水COD是否连续两次超标?"
  5538. },
  5539. {
  5540. "from": "gpt",
  5541. "value": "存在"
  5542. },
  5543. {
  5544. "from": "human",
  5545. "value": "状态:基本确认出水COD超标了\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  5546. }
  5547. ]
  5548. },
  5549. {
  5550. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.15mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.94mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为500.89mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.35%,管控值为80%。\n池2污泥沉降比:当前值为60.65%,管控值为80%。\n池1污泥体积指数:当前值为133.15mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.68mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5551. "conversations": [
  5552. {
  5553. "from": "human",
  5554. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  5555. },
  5556. {
  5557. "from": "gpt",
  5558. "value": "正常"
  5559. },
  5560. {
  5561. "from": "human",
  5562. "value": "出水COD是否连续两次超标?"
  5563. },
  5564. {
  5565. "from": "gpt",
  5566. "value": "不存在"
  5567. },
  5568. {
  5569. "from": "human",
  5570. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  5571. },
  5572. {
  5573. "from": "gpt",
  5574. "value": "超标"
  5575. },
  5576. {
  5577. "from": "human",
  5578. "value": "状态:人工化验比对,出水COD超标了。\n解决方案:出水COD指标超限值标准,立即启动应急预案开展相关工艺调整,与行业主管部门报备并建立联动机制,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  5579. }
  5580. ]
  5581. },
  5582. {
  5583. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.60mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.46mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为501.82mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.87%,管控值为80%。\n池2污泥沉降比:当前值为60.06%,管控值为80%。\n池1污泥体积指数:当前值为136.89mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.60mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5584. "conversations": [
  5585. {
  5586. "from": "human",
  5587. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  5588. },
  5589. {
  5590. "from": "gpt",
  5591. "value": "正常"
  5592. },
  5593. {
  5594. "from": "human",
  5595. "value": "出水COD是否连续两次超标?"
  5596. },
  5597. {
  5598. "from": "gpt",
  5599. "value": "不存在"
  5600. },
  5601. {
  5602. "from": "human",
  5603. "value": "{{alert}}\n请第一时间取样与实验室人工或智能检测化验比对,是否超标了"
  5604. },
  5605. {
  5606. "from": "gpt",
  5607. "value": "不超标"
  5608. },
  5609. {
  5610. "from": "human",
  5611. "value": "状态:人工化验出水COD不超标\n解决方案:化验室检测未超标,暂时关闭报警,持续观察出水水质;"
  5612. }
  5613. ]
  5614. },
  5615. {
  5616. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为-0.02mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为600.81mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为501.63mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.08%,管控值为80%。\n池2污泥沉降比:当前值为60.19%,管控值为80%。\n池1污泥体积指数:当前值为134.32mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.43mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5617. "conversations": [
  5618. {
  5619. "from": "human",
  5620. "value": "{{alert}}\n出水COD在线仪表是正常的吗?"
  5621. },
  5622. {
  5623. "from": "gpt",
  5624. "value": "不正常"
  5625. },
  5626. {
  5627. "from": "human",
  5628. "value": "状态:仪表不正常\n解决方案:\n1、是否存在设备故障,水样通路、检测药剂更换等问题;\n2、查询仪表代维公司是否在进行周/月度/季度的质控核查或比对,如果在进行核查或比对,通过后,需完成监测平台标记记录;若比对时间超过6h或更长时间,需完成主管局备案并监测平台标记,必要时采取第三方取样人工监测,监测周期间隔不大于6 h,数据报送每天不少于4次(具体按属地监管要求执行),监测技术要求参照HJ91.1执行;"
  5629. }
  5630. ]
  5631. },
  5632. {
  5633. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.06mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为599.81mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为503.89mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.92%,管控值为80%。\n池2污泥沉降比:当前值为59.97%,管控值为80%。\n池1污泥体积指数:当前值为134.14mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.34mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.22mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5634. "conversations": [
  5635. {
  5636. "from": "human",
  5637. "value": "进水COD高于设计值?"
  5638. },
  5639. {
  5640. "from": "gpt",
  5641. "value": "低于设计值"
  5642. },
  5643. {
  5644. "from": "human",
  5645. "value": "进水总量与设计值的比较是?"
  5646. },
  5647. {
  5648. "from": "gpt",
  5649. "value": "小于设计值"
  5650. },
  5651. {
  5652. "from": "human",
  5653. "value": ""
  5654. }
  5655. ]
  5656. },
  5657. {
  5658. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.38mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为601.71mg/L,设计值为630mg/L。\n进水水温:当前值是11.54℃。\n进水TDS:当前值为500.36mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.98%,管控值为80%。\n池2污泥沉降比:当前值为59.77%,管控值为80%。\n池1污泥体积指数:当前值为133.28mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.65mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5659. "conversations": [
  5660. {
  5661. "from": "human",
  5662. "value": "进水COD高于设计值?"
  5663. },
  5664. {
  5665. "from": "gpt",
  5666. "value": "低于设计值"
  5667. },
  5668. {
  5669. "from": "human",
  5670. "value": "进水总量与设计值的比较是?"
  5671. },
  5672. {
  5673. "from": "gpt",
  5674. "value": "大于但未超过110%"
  5675. },
  5676. {
  5677. "from": "human",
  5678. "value": "状态:进水COD未超设计值,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  5679. }
  5680. ]
  5681. },
  5682. {
  5683. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.96mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为598.40mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.75mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.80%,管控值为80%。\n池2污泥沉降比:当前值为60.82%,管控值为80%。\n池1污泥体积指数:当前值为135.25mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.64mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5684. "conversations": [
  5685. {
  5686. "from": "human",
  5687. "value": "进水COD高于设计值?"
  5688. },
  5689. {
  5690. "from": "gpt",
  5691. "value": "低于设计值"
  5692. },
  5693. {
  5694. "from": "human",
  5695. "value": "进水总量与设计值的比较是?"
  5696. },
  5697. {
  5698. "from": "gpt",
  5699. "value": "超过110%"
  5700. },
  5701. {
  5702. "from": "human",
  5703. "value": "状态:进水COD未超设计值,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  5704. }
  5705. ]
  5706. },
  5707. {
  5708. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.37mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为650.66mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为501.58mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.16%,管控值为80%。\n池2污泥沉降比:当前值为59.11%,管控值为80%。\n池1污泥体积指数:当前值为134.62mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.31mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.20mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5709. "conversations": [
  5710. {
  5711. "from": "human",
  5712. "value": "进水COD高于设计值?"
  5713. },
  5714. {
  5715. "from": "gpt",
  5716. "value": "高于设计值但是低于110%"
  5717. },
  5718. {
  5719. "from": "human",
  5720. "value": "进水总量与设计值的比较是?"
  5721. },
  5722. {
  5723. "from": "gpt",
  5724. "value": "小于设计值"
  5725. },
  5726. {
  5727. "from": "human",
  5728. "value": ""
  5729. }
  5730. ]
  5731. },
  5732. {
  5733. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.19mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为649.21mg/L,设计值为630mg/L。\n进水水温:当前值是11.50℃。\n进水TDS:当前值为503.23mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.87%,管控值为80%。\n池2污泥沉降比:当前值为60.90%,管控值为80%。\n池1污泥体积指数:当前值为133.05mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.76mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5734. "conversations": [
  5735. {
  5736. "from": "human",
  5737. "value": "进水COD高于设计值?"
  5738. },
  5739. {
  5740. "from": "gpt",
  5741. "value": "高于设计值但是低于110%"
  5742. },
  5743. {
  5744. "from": "human",
  5745. "value": "进水总量与设计值的比较是?"
  5746. },
  5747. {
  5748. "from": "gpt",
  5749. "value": "大于但未超过110%"
  5750. },
  5751. {
  5752. "from": "human",
  5753. "value": "状态:进水COD未超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  5754. }
  5755. ]
  5756. },
  5757. {
  5758. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.42mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为648.81mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为503.90mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.03%,管控值为80%。\n池2污泥沉降比:当前值为60.63%,管控值为80%。\n池1污泥体积指数:当前值为135.60mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.70mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5759. "conversations": [
  5760. {
  5761. "from": "human",
  5762. "value": "进水COD高于设计值?"
  5763. },
  5764. {
  5765. "from": "gpt",
  5766. "value": "高于设计值但是低于110%"
  5767. },
  5768. {
  5769. "from": "human",
  5770. "value": "进水总量与设计值的比较是?"
  5771. },
  5772. {
  5773. "from": "gpt",
  5774. "value": "超过110%"
  5775. },
  5776. {
  5777. "from": "human",
  5778. "value": "状态:进水COD未超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  5779. }
  5780. ]
  5781. },
  5782. {
  5783. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.88mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.63mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.54℃。\n进水TDS:当前值为501.81mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.11%,管控值为80%。\n池2污泥沉降比:当前值为59.19%,管控值为80%。\n池1污泥体积指数:当前值为135.49mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.51mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5784. "conversations": [
  5785. {
  5786. "from": "human",
  5787. "value": "进水COD高于设计值?"
  5788. },
  5789. {
  5790. "from": "gpt",
  5791. "value": "高于设计值110%"
  5792. },
  5793. {
  5794. "from": "human",
  5795. "value": "进水总量与设计值的比较是?"
  5796. },
  5797. {
  5798. "from": "gpt",
  5799. "value": "小于设计值"
  5800. },
  5801. {
  5802. "from": "human",
  5803. "value": ""
  5804. }
  5805. ]
  5806. },
  5807. {
  5808. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.74mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.28mg/L,设计值为630mg/L。\n进水水温:当前值是11.53℃。\n进水TDS:当前值为501.41mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.15%,管控值为80%。\n池2污泥沉降比:当前值为59.82%,管控值为80%。\n池1污泥体积指数:当前值为135.89mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.70mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.15mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是大于但未超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5809. "conversations": [
  5810. {
  5811. "from": "human",
  5812. "value": "进水COD高于设计值?"
  5813. },
  5814. {
  5815. "from": "gpt",
  5816. "value": "高于设计值110%"
  5817. },
  5818. {
  5819. "from": "human",
  5820. "value": "进水总量与设计值的比较是?"
  5821. },
  5822. {
  5823. "from": "gpt",
  5824. "value": "大于但未超过110%"
  5825. },
  5826. {
  5827. "from": "human",
  5828. "value": "状态:进水COD超设计值110%,进水COD总量未超进水COD总量设计值110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、工艺调整优化等工作。\n2、风量调整:调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的可按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n3、污泥回流量调整:增大的幅度每次10%(根据实际情况可适当调整),A²O等连续流工艺以生化池停留时间为单位,CASS等间歇式工艺以至少1个完整周期时间为为单位,检测校核调整效果。\n4、污泥浓度控制调整:减少排泥或接种污泥,提高污泥浓度进一步降低污泥负荷,调整幅度控制不超过常态稳定时的10%,A²O等连续流、CASS等间歇式工艺均以日为单位,检测校核调整效果。"
  5829. }
  5830. ]
  5831. },
  5832. {
  5833. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.15mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.75mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为500.94mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.90%,管控值为80%。\n池2污泥沉降比:当前值为59.56%,管控值为80%。\n池1污泥体积指数:当前值为133.15mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.03mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是超过110%\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5834. "conversations": [
  5835. {
  5836. "from": "human",
  5837. "value": "进水COD高于设计值?"
  5838. },
  5839. {
  5840. "from": "gpt",
  5841. "value": "高于设计值110%"
  5842. },
  5843. {
  5844. "from": "human",
  5845. "value": "进水总量与设计值的比较是?"
  5846. },
  5847. {
  5848. "from": "gpt",
  5849. "value": "超过110%"
  5850. },
  5851. {
  5852. "from": "human",
  5853. "value": "状态:进水COD超设计值110%,进水COD总量超过进水COD总量设计值的110%\n解决方案:\n1、向行业主管部门报备、开展水质溯源进行源头控制、启动应急预案等工作。\n2、优先采取降负荷运行方式:具备条件且无环保风险的前提下,按照污染物负荷总量核算运行负荷或根据应急预案执行。\n3、不具备降负荷条件时,可以利用厂内初沉池、水解酸化等预处理设施池容,对超标水进行错峰调蓄,最大限度保障生化系统进水水质均衡。\n4、当系统长时间受到超标冲击,远超系统处理能力时,系统面临瘫痪风险,根据现场实际情况,可选择性进行系统保留和放弃,即停进水闷曝内循环系统和进水运行负荷系统;\n5、运行负荷调整涉及管网的污水溢流问题,事关环保风险责任,因此启动应急预案落实负荷调整时要完成主管报备,必要时同步联动专家论证程序,确保合法合规。"
  5854. }
  5855. ]
  5856. },
  5857. {
  5858. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.99mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.96mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.53℃。\n进水TDS:当前值为502.45mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.41%,管控值为80%。\n池2污泥沉降比:当前值为59.96%,管控值为80%。\n池1污泥体积指数:当前值为133.03mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.10mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为3.13mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5859. "conversations": [
  5860. {
  5861. "from": "human",
  5862. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  5863. },
  5864. {
  5865. "from": "gpt",
  5866. "value": "都未低于"
  5867. },
  5868. {
  5869. "from": "human",
  5870. "value": ""
  5871. }
  5872. ]
  5873. },
  5874. {
  5875. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.07mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.98mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为500.41mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.72%,管控值为80%。\n池2污泥沉降比:当前值为60.02%,管控值为80%。\n池1污泥体积指数:当前值为135.88mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.59mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为3.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5876. "conversations": [
  5877. {
  5878. "from": "human",
  5879. "value": "各个池子的好氧池溶解氧是否低于各自的稳态值?"
  5880. },
  5881. {
  5882. "from": "gpt",
  5883. "value": "至少一个池子有低于"
  5884. },
  5885. {
  5886. "from": "human",
  5887. "value": "状态:好氧池溶解氧偏低\n解决方案:\n1、解决供风量不足导致的生化池DO过低\n首先查看风机状态,尝试提高已运行风机风量(调整幅度每次5%(根据实际情况可适当调整),有气量计量的的以读数为准,没有的按照变频器的频率和额定风量核算,以气水比的数值和实际溶解氧校核);其次,启动或切换备用风机,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。\n2、供风量充足,解决曝气管路不畅、漏气等导致的生化池DO过低\n(1)定期及时排出曝气管路中的领凝水保障管路通常。(2)水面上漏点直接维修;水面下漏点,具备停进水条件的放空后维修,不具备的则按环保要求完成备案同意后,争取最短时间内恢复,在此期间根据实际情况灵活采取过渡措施予以保障。\n3、供风量充足,解决曝气器破损或脱落等导致的生化池DO过低\n关闭或调小泄漏处阀门,减小气量损失,保障生化池充氧效果。具备停水放空条件,及时维修或更换。在此期间根据实际情况灵活采取过渡措施予以保障。\n4、供风量充足,解决生化池负或液位差异导致生化池气量分配不均导致的DO过低\n调整各系统进水和污泥回流阀门,尽可能保障运行工况一致,进行各系统供气总阀和局部阀的调整,A²O等连续流工艺调整后3~5小时后检测DO校核,CASS等间歇式工艺按工艺下一个周期检测DO校核。"
  5888. }
  5889. ]
  5890. },
  5891. {
  5892. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.03mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为771.77mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为502.82mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.04%,管控值为80%。\n池2污泥沉降比:当前值为59.97%,管控值为80%。\n池1污泥体积指数:当前值为136.89mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.91mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5893. "conversations": [
  5894. {
  5895. "from": "human",
  5896. "value": "进水水温是否小于8℃"
  5897. },
  5898. {
  5899. "from": "gpt",
  5900. "value": "否"
  5901. },
  5902. {
  5903. "from": "human",
  5904. "value": ""
  5905. }
  5906. ]
  5907. },
  5908. {
  5909. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.98mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.23mg/L,设计值为630mg/L。\n\n进水水温:当前值是3.54℃。\n进水TDS:当前值为501.29mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.13%,管控值为80%。\n池2污泥沉降比:当前值为59.60%,管控值为80%。\n池1污泥体积指数:当前值为136.14mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.61mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5910. "conversations": [
  5911. {
  5912. "from": "human",
  5913. "value": "进水水温是否小于8℃"
  5914. },
  5915. {
  5916. "from": "gpt",
  5917. "value": "是"
  5918. },
  5919. {
  5920. "from": "human",
  5921. "value": "状态:进水水温小于8℃\n由于水温低于10℃,聚磷菌在低温时生长速度会减慢,生物除磷速率将会迅速下降,微生物活性下降。\n解决方案:\n1、强化温降数据收集与分析,提前预警管控\n一般在10月中旬及3月下旬进入变温期或换季期间,做好温降曲线的统计和绘制工作,秋季进水水温连续3天低于15℃,或春季进水水温连续3天高于12℃时,加强相关指标的检测频次和分析,提前采取运行管理措施和工艺调整。\n2、工艺调整\n(1)适当提高污泥龄,温降或换季期间污水处理厂逐步提高污泥浓度,生化池污泥泥龄一般控制在25~30天;如进水负荷较低(COD不超过150mg/L)情况下,也可控制在20~25天。\n(2)合理控制污泥浓度,根据不同工艺历年来生产运行经验和污泥负荷核算,AO、A²O及改良工艺控制秋冬季低温期污水处理厂污泥浓度控制在4000~6000mg/L;CASS、CAST工艺控制冬季污水处理厂污泥浓度控制在3000~5000mg/L。\n(3)及时调控回流比,温降或换季期间,较常规运行阶段要适当提高外回流比,一般不超过150%。内回流比则根据总氮变化灵活调整,内外总回流比不宜超过400%。"
  5922. }
  5923. ]
  5924. },
  5925. {
  5926. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.37mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.72mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为503.95mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.04%,管控值为80%。\n池2污泥沉降比:当前值为59.11%,管控值为80%。\n池1污泥体积指数:当前值为134.11mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为125.80mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.10mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5927. "conversations": [
  5928. {
  5929. "from": "human",
  5930. "value": "进水TDS是否超出管控值?"
  5931. },
  5932. {
  5933. "from": "gpt",
  5934. "value": "未超出"
  5935. },
  5936. {
  5937. "from": "human",
  5938. "value": ""
  5939. }
  5940. ]
  5941. },
  5942. {
  5943. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.51mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为770.80mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.55℃。\n进水TDS:当前值为653.80mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.90%,管控值为80%。\n池2污泥沉降比:当前值为59.90%,管控值为80%。\n池1污泥体积指数:当前值为136.33mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为126.98mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.21mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.14mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5944. "conversations": [
  5945. {
  5946. "from": "human",
  5947. "value": "进水TDS是否超出管控值?"
  5948. },
  5949. {
  5950. "from": "gpt",
  5951. "value": "超出"
  5952. },
  5953. {
  5954. "from": "human",
  5955. "value": "状态:进水TDS超过管控值\n解决方案:\n1、向行业主管部门报备、开展水质溯源、启动应急预案等工作\n配合主管部门的调查认定,最短时间内完成源头控制,争在第一时间内最大限度降低处理负荷;或利用初沉池、水解酸化池等预处理设施投加絮凝剂提高进水絮凝效果,尽可能减少可沉降性毒性物质进行系统。\n2、开展毒性抑制定性分析\n根据属地重点工业企业排水清单和溯源结果,重点对重金属、典型芳香类化合物等及时开展毒性检测分析,同步进行小试抑制试验,确定进水毒性抑制和生化系统恢复潜力。\n3、毒性小试实验方案\n将现有生化系统活性污泥分别与异常进水和正常进水混合,保证污泥浓度一致条件下开展闷曝小试实验,每 8h 取样 1 次,24h 换水 1 次(换水量为 50%),连续运行 72h,比较不同进水 COD、NH3-N 污染物去除效率,根据实验结果确定:① 探究污水厂进水是否对活性良好的微生物菌群产生延时毒性抑制作用;② 探究生化系统内活性污泥的硝化效能;③探究解决当前生化池硝化抑制问题的适宜应对策略。\n4、恢复毒性抑制的关键工艺调整\n根据毒性抑制试验结果,化系统COD去除率50%以上且不再继续降低,应尽可能最短时间完成优质外源活性污泥接种,随着驯化成熟,COD去除率不断升高,可同步加大剩余污泥排放,进行新老活性污泥的置换,根据实际情况也可尝试定向微生物菌剂投加等措施,缩短系统恢复时间。同时在调整期间提高相应参数、指标的检测频次和分析。\n5、长时间毒性冲击系统,应对措施\n系统濒临瘫痪,无法短期完成恢复的,及时启动专家论证程序,联动省市主管部门,落实具体方案,将生态环境损害降至最低,免于环保问责或处罚。"
  5956. }
  5957. ]
  5958. },
  5959. {
  5960. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.00mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.56mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.51℃。\n进水TDS:当前值为502.19mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.55%,管控值为80%。\n池2污泥沉降比:当前值为60.38%,管控值为80%。\n池1污泥体积指数:当前值为136.02mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.86mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.24mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.11mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5961. "conversations": [
  5962. {
  5963. "from": "human",
  5964. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  5965. },
  5966. {
  5967. "from": "gpt",
  5968. "value": "都未超过"
  5969. },
  5970. {
  5971. "from": "human",
  5972. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  5973. },
  5974. {
  5975. "from": "gpt",
  5976. "value": "否"
  5977. },
  5978. {
  5979. "from": "human",
  5980. "value": ""
  5981. }
  5982. ]
  5983. },
  5984. {
  5985. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为35.51mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为768.17mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.50℃。\n进水TDS:当前值为503.05mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为62.68%,管控值为80%。\n池2污泥沉降比:当前值为60.32%,管控值为80%。\n池1污泥体积指数:当前值为136.34mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为127.20mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.23mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  5986. "conversations": [
  5987. {
  5988. "from": "human",
  5989. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  5990. },
  5991. {
  5992. "from": "gpt",
  5993. "value": "都未超过"
  5994. },
  5995. {
  5996. "from": "human",
  5997. "value": "{{alert}}\n生化池是否有大量泡沫、浮泥等不正常现象"
  5998. },
  5999. {
  6000. "from": "gpt",
  6001. "value": "是"
  6002. },
  6003. {
  6004. "from": "human",
  6005. "value": "状态:生化池有大量泡沫、浮泥等不正常现象\n由于生化池出现大量泡沫、浮泥等不正常现象,可能是污泥膨胀、老化、解絮等导致微生物活性下降,导致出水带泥。\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  6006. }
  6007. ]
  6008. },
  6009. {
  6010. "system": "作为一位经验丰富的污水处理厂专家。COD(化学需氧量)是衡量水中有机物污染程度的一个重要指标。出水COD超标意味着排放的水仍然含有较高浓度的有机污染物,不符合排放标准。\n污水处理厂的关键指标数据如下:\n出水COD:当前值为36.52mg/L,设计值为40mg/L,管控值为32mg/L。\n进水COD:当前值为769.11mg/L,设计值为630mg/L。\n\n进水水温:当前值是11.52℃。\n进水TDS:当前值为500.67mg/L,管控值为600mg/L。\n池1污泥沉降比:当前值为61.46%,管控值为80%。\n池2污泥沉降比:当前值为89.77%,管控值为80%。\n池1污泥体积指数:当前值为134.58mL/g,管控值为170mL/g。\n池2污泥体积指数:当前值为124.69mL/g,管控值为170mL/g。\n池1好氧池溶解氧:当前值为2.25mg/L,稳态值为2.5mg/L。\n池2好氧池溶解氧:当前值为2.12mg/L,稳态值为2.5mg/L。\n出水COD不存在连续两个相邻检测数据超标。\n进水总量与设计值的比较是小于设计值\n根据以上信息,请回答以下问题,只需给出问题后括号内的选项即可,无需解释:\n\n出水COD是否存在连续两次超标?(存在/不存在)。\n进水COD高于设计值?(低于设计值/高于设计值但是低于110%/高于设计值110%)。\n每个池子的好氧池溶解氧是否低于各自的稳态值?(至少一个池子有低于/都未低于)。\n进水水温是否小于8℃?(是/否)。\n进水TDS是否超出管控值?(超出/未超出)。\n每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?(都未超过/至少一个池子有超过)。\n进水总量与设计值的比较是?(小于设计值/大于但未超过110%/超过110%)。",
  6011. "conversations": [
  6012. {
  6013. "from": "human",
  6014. "value": "每个池子的污泥沉降比和污泥体积指数是否超过各自对应的管控值?"
  6015. },
  6016. {
  6017. "from": "gpt",
  6018. "value": "至少一个池子有超过"
  6019. },
  6020. {
  6021. "from": "human",
  6022. "value": "状态:污泥沉降比或污泥体积指数异常\n解决方案:\n1、强化污泥SV、SVI和镜检的污泥性状分析,按照污泥膨胀、老化、解絮等对症管控措施,及时完成工艺调整,将污泥负荷控制在设计管控目标内。\n2、系统恢复应急期调整\n①重新进行活性污泥接种和驯化;\n②根据生化反应中出现问题选择相适应的微生物菌剂、污泥调理剂进行系统定向强化\n3、短期内无法解决恢复时,应及时完成主管部门报备和专家论证等免责程序,并启动应急预案"
  6023. }
  6024. ]
  6025. }
  6026. ]